Commit Graph

56 Commits

Author SHA1 Message Date
Ollo
9167da5a82 Refactoring 2023-06-20 18:06:29 +02:00
Ollo
6cb446735d Adapted default work time, as internal time is UTC 2023-05-28 10:53:43 +02:00
Ollo
712ef73a30 Merged master into ollo-dev 2023-03-10 20:06:05 +01:00
Empire
63ed9afabc stuff changed 2023-03-03 19:58:55 +01:00
Empire
3835bd96a1 Revert "Revert "add resistive frequency sensor, updated dependencies""
This reverts commit 42ce4cdda2.
2023-02-12 12:51:52 +01:00
Empire
42ce4cdda2 Revert "add resistive frequency sensor, updated dependencies"
This reverts commit 17d16a6eef.
2023-02-12 12:40:38 +01:00
Empire
68386ce02f Merge branch 'master' of github.com:0110/PlantCtrl 2023-02-10 22:12:57 +01:00
Empire
17d16a6eef add resistive frequency sensor, updated dependencies 2023-02-10 22:08:29 +01:00
Your Name
43e638a587 set more state retained 2022-12-20 00:07:25 +01:00
Ollo
18b927bd59 Publish state as number and string 2022-08-21 12:05:43 +02:00
Ollo
c444117853 code refactoring: use the defined states of header file 2022-08-21 11:59:50 +02:00
662d7bc853 add timer only mode, more sane default config 2022-05-20 01:00:04 +02:00
7a841d423b use more sane default (pump always not only at night) 2022-04-29 10:45:59 +02:00
Empire
c43da98245 Merge branch 'hydro'
# Conflicts:
#	esp32/PlantControl.code-workspace
#	esp32/include/ControllerConfiguration.h
#	esp32/platformio.ini
#	esp32/src/main.cpp
2022-04-27 19:19:26 +00:00
Empire
defbcca8ae sht20 support 2022-03-05 09:31:43 +00:00
c3ma
1161c62a90 print into mqtt the sensor mode 2022-02-19 02:51:36 +01:00
c3ma
a0f8df7016 fix for capacitive sensors not working, enum introduction for sensormode 2022-02-19 02:24:19 +01:00
c3ma
d0320beaa7 allow sensor type selection per plant, changed calculations to use PCT values, due to different raw value meaning 2022-02-12 05:26:54 +01:00
Empire
b9d8831dea Merge branch 'master' of github.com:0110/PlantCtrl
# Conflicts:
#	esp32/src/main.cpp
2021-12-03 18:42:37 +00:00
Empire
d69feb4143 basic pump ml calculation 2021-12-03 18:36:10 +00:00
Ollo
16a722816c Use only Homie compliant datatypes: https://homieiot.github.io/specification/spec-core-v3_0_1/# 2021-11-29 17:25:08 +01:00
Your Name
7d80d444cf use only seconds for time units, improve self test debug 2021-10-27 01:42:01 +02:00
Your Name
2c8645121e added pump specific power level (requires controller that supports this or dc motor) 2021-10-26 21:50:55 +02:00
Your Name
9170a1fe05 some fixes for hydroponics mode 2021-10-26 20:46:40 +02:00
Empire
49664ba6f7 added initial support for hydroponic systems, changed cooldown to use minutes 2021-10-22 17:39:42 +00:00
c3ma
2cd0a0f48b initial flowmeter logic and calculation 2021-10-06 21:24:34 +02:00
Your Name
f4e13454e3 wip new pump system 2021-10-01 23:46:37 +02:00
Your Name
e927fc8c70 add alarm if pumps did not change state to wet after X consecutive tries 2021-08-23 00:58:37 +02:00
Your Name
61098724b6 fixed wrong percent calculation, emit trigger value to mqtt 2021-08-17 16:55:57 +02:00
c3ma
d043d873cc Reading sensors by frequency 2021-07-21 21:23:58 +02:00
Ollo
2d167c7393 adapted datatype 2021-07-14 21:43:03 +02:00
Ollo
c448960415 Check values before publishing water stuff 2021-07-14 21:14:03 +02:00
c3ma
2d91f91290 react on switch from Mqtt 2021-07-09 22:51:50 +02:00
c3ma
df39c09c50 code cleanups 2021-07-09 21:50:51 +02:00
Ollo
57d18af76d converted serial prints into MQTT status log messages 2021-07-01 22:06:50 +02:00
Your Name
f1d55ed603 extracte time stuff, started logger 2021-07-01 21:19:51 +02:00
Your Name
7c9a0bf6f1 clear averages for each run, ignore distances higher than tank depth 2021-07-01 20:39:51 +02:00
Your Name
a1de9ee2b9 config reduced, config json parser memory adjusted 2021-06-29 23:49:48 +02:00
Your Name
98799bd2d5 added testmode, fixed formating 2021-05-26 21:46:33 +02:00
Your Name
92005c1c33 control works again (fixed with wifi and fallback) 2021-05-24 14:58:35 +02:00
23beebc4be pin fix 2020-12-20 17:00:44 +01:00
a14f599f5a missing sensor detection, delta trigger moisture working 2020-11-04 23:28:08 +01:00
503c2b73b9 added raw moisture, improved pct calc , formating 2020-11-04 21:57:40 +01:00
c3ma
a140383e32 Disable pumps while OTA running, mode2 is called only once 2020-10-28 21:20:46 +01:00
c3ma
3e3eaa96e4 Refactored code 2020-10-23 16:20:34 +02:00
c3ma
9b5bf90da9 settings gpio mode before deepsleep 2020-10-21 20:46:09 +02:00
0a473173f8 reduced settings 2020-10-20 22:52:03 +02:00
c3ma
b9ca98904d Read settings and store into non volatile memory 2020-10-16 21:12:25 +02:00
c3ma
8458912962 Configuration can be used with default values 2020-10-16 18:40:39 +02:00
c3ma
e95590ffd6 Setting works with default values 2020-10-16 18:25:02 +02:00