extracte time stuff, started logger
This commit is contained in:
parent
a1f2388c7f
commit
f1d55ed603
14
esp32/include/LogDefines.h
Normal file
14
esp32/include/LogDefines.h
Normal file
@ -0,0 +1,14 @@
|
||||
#pragma once
|
||||
|
||||
#define LOG_LEVEL_ERROR 0
|
||||
#define LOG_LEVEL_WARN 1
|
||||
#define LOG_LEVEL_INFO 2
|
||||
|
||||
#define LOG_TANKSENSOR_FAIL_DETECT "Failed to detect and initialize distance sensor!"
|
||||
#define LOG_TANKSENSOR_FAIL_DETECT_CODE -1
|
||||
|
||||
#define LOG_BACKUP_SUCCESSFUL "Backup sucessful"
|
||||
#define LOG_BACKUP_SUCCESSFUL_CODE 1
|
||||
|
||||
#define LOG_BACKUP_FAILED "Backup error"
|
||||
#define LOG_BACKUP_FAILED_CODE -2
|
4
esp32/include/TimeUtils.h
Normal file
4
esp32/include/TimeUtils.h
Normal file
@ -0,0 +1,4 @@
|
||||
#pragma once
|
||||
|
||||
long getCurrentTime(void);
|
||||
int getCurrentHour(void);
|
@ -12,6 +12,7 @@
|
||||
|
||||
#include "PlantCtrl.h"
|
||||
#include "ControllerConfiguration.h"
|
||||
#include "TimeUtils.h"
|
||||
|
||||
Plant::Plant(int pinSensor, int pinPump, int plantId, HomieNode *plant, PlantSettings_t *setting)
|
||||
{
|
||||
@ -95,6 +96,7 @@ void Plant::activatePump(void)
|
||||
{
|
||||
const String OFF = String("ON");
|
||||
this->mPlant->setProperty("switch").send(OFF);
|
||||
this->mPlant->setProperty("lastPump").send(String(getCurrentTime()));
|
||||
}
|
||||
}
|
||||
|
||||
@ -102,6 +104,7 @@ void Plant::advertise(void)
|
||||
{
|
||||
// Advertise topics
|
||||
this->mPlant->advertise("switch").setName("Pump 1").setDatatype("boolean");
|
||||
this->mPlant->advertise("lastPump").setName("lastPump").setDatatype("number").setUnit("unixtime");
|
||||
//FIXME add .settable(this->switchHandler)
|
||||
this->mPlant->advertise("moist").setName("Percent").setDatatype("number").setUnit("%");
|
||||
this->mPlant->advertise("moistraw").setName("adc").setDatatype("number").setUnit("3.3/4096V");
|
||||
|
18
esp32/src/TimeUtils.cpp
Normal file
18
esp32/src/TimeUtils.cpp
Normal file
@ -0,0 +1,18 @@
|
||||
#include "TimeUtils.h"
|
||||
#include <Homie.h>
|
||||
|
||||
long getCurrentTime()
|
||||
{
|
||||
struct timeval tv_now;
|
||||
gettimeofday(&tv_now, NULL);
|
||||
return tv_now.tv_sec;
|
||||
}
|
||||
|
||||
int getCurrentHour()
|
||||
{
|
||||
struct tm info;
|
||||
time_t now;
|
||||
time(&now);
|
||||
localtime_r(&now, &info);
|
||||
return info.tm_hour;
|
||||
}
|
@ -13,7 +13,9 @@
|
||||
/******************************************************************************
|
||||
* INCLUDES
|
||||
******************************************************************************/
|
||||
#include "LogDefines.h"
|
||||
#include "FileUtils.h"
|
||||
#include "TimeUtils.h"
|
||||
#include "PlantCtrl.h"
|
||||
#include "ControllerConfiguration.h"
|
||||
#include "HomieConfiguration.h"
|
||||
@ -38,8 +40,8 @@
|
||||
#define AMOUNT_SENOR_QUERYS 8
|
||||
#define MAX_TANK_DEPTH 2000
|
||||
#define TEST_TOPIC "roundtrip\0"
|
||||
#define LOG_TOPIC "log\0"
|
||||
#define BACKUP_TOPIC "$implementation/config/backup/set\0"
|
||||
#define BACKUP_STATUS_TOPIC "$implementation/config/backup\0"
|
||||
#define CONFIG_FILE "/homie/config.json"
|
||||
#define CONFIG_FILE_BACKUP "/homie/config.json.bak"
|
||||
|
||||
@ -54,6 +56,7 @@
|
||||
* FUNCTION PROTOTYPES
|
||||
******************************************************************************/
|
||||
|
||||
void log(int level, String message, int code);
|
||||
int determineNextPump();
|
||||
void plantcontrol();
|
||||
void readPowerSwitchedSensors();
|
||||
@ -101,21 +104,7 @@ Plant mPlants[MAX_PLANTS] = {
|
||||
/******************************************************************************
|
||||
* LOCAL FUNCTIONS
|
||||
******************************************************************************/
|
||||
long getCurrentTime()
|
||||
{
|
||||
struct timeval tv_now;
|
||||
gettimeofday(&tv_now, NULL);
|
||||
return tv_now.tv_sec;
|
||||
}
|
||||
|
||||
int getCurrentHour()
|
||||
{
|
||||
struct tm info;
|
||||
time_t now;
|
||||
time(&now);
|
||||
localtime_r(&now, &info);
|
||||
return info.tm_hour;
|
||||
}
|
||||
|
||||
void espDeepSleepFor(long seconds, bool activatePump)
|
||||
{
|
||||
@ -321,10 +310,12 @@ void readPowerSwitchedSensors()
|
||||
|
||||
for (int readCnt = 0; readCnt < 5; readCnt++)
|
||||
{
|
||||
if(!tankSensor.timeoutOccurred()){
|
||||
if (!tankSensor.timeoutOccurred())
|
||||
{
|
||||
uint16_t distance = tankSensor.readRangeSingleMillimeters();
|
||||
if(distance < MAX_TANK_DEPTH){
|
||||
waterRawSensor.add(distance);
|
||||
if (distance < MAX_TANK_DEPTH)
|
||||
{
|
||||
waterRawSensor.add(distance);
|
||||
}
|
||||
}
|
||||
delay(10);
|
||||
@ -333,7 +324,7 @@ void readPowerSwitchedSensors()
|
||||
}
|
||||
else
|
||||
{
|
||||
Serial.println("Failed to detect and initialize distance sensor!");
|
||||
log(LOG_LEVEL_WARN,LOG_TANKSENSOR_FAIL_DETECT,LOG_TANKSENSOR_FAIL_DETECT_CODE);
|
||||
}
|
||||
|
||||
/* deactivate the sensors */
|
||||
@ -351,12 +342,15 @@ void onMessage(char *incoming, char *payload, AsyncMqttClientMessageProperties p
|
||||
getTopic(BACKUP_TOPIC, backupTopic);
|
||||
if (strcmp(incoming, backupTopic) == 0)
|
||||
{
|
||||
if(strcmp(payload, "true") == 0){
|
||||
if (strcmp(payload, "true") == 0)
|
||||
{
|
||||
bool backupSucessful = copyFile(CONFIG_FILE, CONFIG_FILE_BACKUP);
|
||||
printFile(CONFIG_FILE_BACKUP);
|
||||
getTopic(BACKUP_STATUS_TOPIC, backupStatusTopic);
|
||||
Homie.getMqttClient().publish(backupStatusTopic, 2, true, backupSucessful ? "true" : "false");
|
||||
delete backupStatusTopic;
|
||||
if(backupSucessful){
|
||||
log(LOG_LEVEL_INFO,LOG_BACKUP_SUCCESSFUL, LOG_BACKUP_SUCCESSFUL_CODE);
|
||||
}else {
|
||||
log(LOG_LEVEL_INFO,LOG_BACKUP_FAILED, LOG_BACKUP_FAILED_CODE);
|
||||
}
|
||||
Homie.getMqttClient().publish(backupTopic, 2, true, "false");
|
||||
}
|
||||
}
|
||||
@ -557,8 +551,6 @@ void setup()
|
||||
// read button
|
||||
pinMode(BUTTON, INPUT);
|
||||
|
||||
|
||||
|
||||
// Power pins
|
||||
pinMode(OUTPUT_ENABLE_PUMP, OUTPUT);
|
||||
|
||||
@ -578,7 +570,6 @@ void setup()
|
||||
Serial << "Limits.hpp is not adjusted, please search for this string and increase" << endl;
|
||||
return;
|
||||
}
|
||||
|
||||
|
||||
/************************* Start One-Wire bus ***************/
|
||||
int tempInitStartTime = millis();
|
||||
@ -613,7 +604,8 @@ void setup()
|
||||
// Set default values
|
||||
|
||||
//in seconds
|
||||
deepSleepTime.setDefaultValue(600).setValidator([](long candidate) { return (candidate > 0) && (candidate < (60 * 60 * 2) /** 2h max sleep */); });
|
||||
deepSleepTime.setDefaultValue(600).setValidator([](long candidate)
|
||||
{ return (candidate > 0) && (candidate < (60 * 60 * 2) /** 2h max sleep */); });
|
||||
deepSleepNightTime.setDefaultValue(600);
|
||||
wateringDeepSleep.setDefaultValue(5);
|
||||
ntpServer.setDefaultValue("pool.ntp.org");
|
||||
@ -628,7 +620,6 @@ void setup()
|
||||
Homie.onEvent(onHomieEvent);
|
||||
//Homie.disableLogging();
|
||||
|
||||
|
||||
Homie.setup();
|
||||
|
||||
mConfigured = Homie.isConfigured();
|
||||
@ -673,20 +664,22 @@ void setup()
|
||||
else
|
||||
{
|
||||
printFile("/homie/Readme.md");
|
||||
if (doesFileExist(CONFIG_FILE)){
|
||||
if (doesFileExist(CONFIG_FILE))
|
||||
{
|
||||
printFile(CONFIG_FILE);
|
||||
}
|
||||
if (doesFileExist(CONFIG_FILE_BACKUP)){
|
||||
if (doesFileExist(CONFIG_FILE_BACKUP))
|
||||
{
|
||||
printFile(CONFIG_FILE_BACKUP);
|
||||
bool restoredConfig = copyFile(CONFIG_FILE_BACKUP, CONFIG_FILE);
|
||||
if(restoredConfig){
|
||||
deleteFile(CONFIG_FILE_BACKUP);
|
||||
espDeepSleepFor(1,false);
|
||||
return;
|
||||
if (restoredConfig)
|
||||
{
|
||||
deleteFile(CONFIG_FILE_BACKUP);
|
||||
espDeepSleepFor(1, false);
|
||||
return;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
readOneWireSensors();
|
||||
//prevent BOD to be paranoid
|
||||
WRITE_PERI_REG(RTC_CNTL_BROWN_OUT_REG, 0);
|
||||
@ -876,3 +869,23 @@ void plantcontrol()
|
||||
}
|
||||
|
||||
/** @}*/
|
||||
|
||||
void log(int level, String message, int statusCode)
|
||||
{
|
||||
String buffer;
|
||||
StaticJsonDocument<200> doc;
|
||||
doc["level"] = level;
|
||||
doc["message"] = message;
|
||||
doc["statusCode"] = statusCode;
|
||||
serializeJson(doc, buffer);
|
||||
if (mAliveWasRead)
|
||||
{
|
||||
getTopic(LOG_TOPIC, logTopic)
|
||||
Homie.getMqttClient()
|
||||
.subscribe(logTopic, 2);
|
||||
|
||||
Homie.getMqttClient().publish(logTopic, 2, false, buffer.c_str());
|
||||
delete logTopic;
|
||||
}
|
||||
Serial << statusCode << "@" << level << " : " << message << endl;
|
||||
}
|
Loading…
Reference in New Issue
Block a user