Commit Graph

220 Commits

Author SHA1 Message Date
c3ma
1161c62a90 print into mqtt the sensor mode 2022-02-19 02:51:36 +01:00
c3ma
a0f8df7016 fix for capacitive sensors not working, enum introduction for sensormode 2022-02-19 02:24:19 +01:00
c3ma
d0320beaa7 allow sensor type selection per plant, changed calculations to use PCT values, due to different raw value meaning 2022-02-12 05:26:54 +01:00
Ollo
7a54065a5f Reduced frequrency boundery 2022-01-25 22:11:38 +01:00
Empire
b9d8831dea Merge branch 'master' of github.com:0110/PlantCtrl
# Conflicts:
#	esp32/src/main.cpp
2021-12-03 18:42:37 +00:00
Empire
d69feb4143 basic pump ml calculation 2021-12-03 18:36:10 +00:00
Ollo
16a722816c Use only Homie compliant datatypes: https://homieiot.github.io/specification/spec-core-v3_0_1/# 2021-11-29 17:25:08 +01:00
Ollo
9ff546b7b7 Remove Exception stuff 2021-11-28 16:02:08 +01:00
Empire
61fad8e14c Merge branch 'master' of https://github.com/0110/PlantCtrl 2021-11-19 18:58:26 +00:00
Empire
af618e73f3 pump refactor round 1 2021-11-19 18:48:14 +00:00
Ollo
c5bce25afe Added time into logs 2021-11-14 19:49:40 +01:00
Ollo
a457db4447 Fixed memory leak 2021-11-14 13:51:52 +01:00
c3ma
66d69eab6b Exceptions added 2021-11-13 17:26:39 +01:00
c3ma
f727971138 increased ota flash sizes 2021-10-27 22:04:44 +02:00
Your Name
2ad351c41b remove selfTest causing sideeffects for pumploop trigger 2021-10-27 02:05:48 +02:00
Your Name
7d80d444cf use only seconds for time units, improve self test debug 2021-10-27 01:42:01 +02:00
Your Name
e70e467e9b properly set last run time, as it apparently was missing 2021-10-27 00:40:46 +02:00
Your Name
6a97215a04 fix for hydroponic not working at night 2021-10-27 00:40:26 +02:00
Your Name
2c8645121e added pump specific power level (requires controller that supports this or dc motor) 2021-10-26 21:50:55 +02:00
Your Name
dba39869d1 use shorter valid firmeware name 2021-10-26 21:12:00 +02:00
Your Name
9170a1fe05 some fixes for hydroponics mode 2021-10-26 20:46:40 +02:00
Empire
49664ba6f7 added initial support for hydroponic systems, changed cooldown to use minutes 2021-10-22 17:39:42 +00:00
Your Name
0bcef25528 Merge branch 'master' of https://github.com/0110/PlantCtrl 2021-10-22 15:53:58 +02:00
Your Name
f30a0a0c78 smooth battery sensor 2021-10-22 15:52:19 +02:00
Ollo
d819f7df4e Update documentation 2021-10-15 21:59:47 +02:00
c3ma
ecc03e9cb4 mqtt extraction 2021-10-06 22:00:17 +02:00
c3ma
2cd0a0f48b initial flowmeter logic and calculation 2021-10-06 21:24:34 +02:00
c3ma
b5569aa8ab Cleanup of last changes 2021-10-06 20:05:09 +02:00
Your Name
244dfb9b27 Merge branch 'master' of https://github.com/0110/PlantCtrl
# Conflicts:
#	esp32/src/main.cpp
2021-10-01 23:51:29 +02:00
Your Name
f4e13454e3 wip new pump system 2021-10-01 23:46:37 +02:00
Ollo
1619b93fa1 Updated ini.example 2021-10-01 23:00:24 +02:00
Ollo
58cb523e1b added determineTimeLightState in TIMED_LIGHT_PIN define 2021-10-01 22:53:40 +02:00
Your Name
f13a25b34d prevent light from being reenabled untill next day after low voltage trigger 2021-09-14 18:54:14 +02:00
Empire
88e4ceea8b fix for wrong validator 2021-08-30 08:02:12 +00:00
Your Name
f99f72b65a added timed light function 2021-08-29 20:45:50 +02:00
Your Name
e927fc8c70 add alarm if pumps did not change state to wet after X consecutive tries 2021-08-23 00:58:37 +02:00
Your Name
61098724b6 fixed wrong percent calculation, emit trigger value to mqtt 2021-08-17 16:55:57 +02:00
c3ma
2e052710e2 missing sensor error 2021-07-21 21:34:14 +02:00
c3ma
d043d873cc Reading sensors by frequency 2021-07-21 21:23:58 +02:00
Ollo
2d167c7393 adapted datatype 2021-07-14 21:43:03 +02:00
Ollo
f6c51f6d05 Updated example, more debug output in script 2021-07-14 21:33:47 +02:00
Ollo
02a882ebde Seperate setting itself into a local file 2021-07-14 21:21:49 +02:00
Ollo
697d470d29 Renamed file 2021-07-14 21:15:04 +02:00
Ollo
c448960415 Check values before publishing water stuff 2021-07-14 21:14:03 +02:00
c3ma
2d91f91290 react on switch from Mqtt 2021-07-09 22:51:50 +02:00
c3ma
df39c09c50 code cleanups 2021-07-09 21:50:51 +02:00
c3ma
99703e5ad1 Adjust moister sensor boundaries 2021-07-09 19:40:51 +02:00
Your Name
12d4c9950d fix cooldown memory without power, improved logging 2021-07-01 23:09:02 +02:00
Ollo
456f78042c Fixed concatination of strings in logging 2021-07-01 22:15:55 +02:00
Ollo
57d18af76d converted serial prints into MQTT status log messages 2021-07-01 22:06:50 +02:00