fixed wrong indes for pump determination

improved pump status output
fixed led blinking in  mode3 random
This commit is contained in:
Empire 2020-11-04 21:10:22 +01:00
parent 329a228b2d
commit fb907f9b12
2 changed files with 38 additions and 12 deletions

View File

@ -60,9 +60,24 @@ public:
* @return false
*/
bool isPumpRequired() {
return (this->mSetting->pSensorDry != NULL)
&& (this->moistureRaw.getMedian() > this->mSetting->pSensorDry->get())
&& (this->mSetting->pSensorDry->get() != DEACTIVATED_PLANT);
bool isDry = getCurrentMoisture() > getSettingsMoisture();
bool isActive = isPumpTriggerActive();
return isDry && isActive;
}
bool isPumpTriggerActive(){
return this->mSetting->pSensorDry->get() != DEACTIVATED_PLANT;
}
float getCurrentMoisture(){
return this->moistureRaw.getMedian();
}
long getSettingsMoisture(){
if(this->mSetting->pSensorDry != NULL){
return this->mSetting->pSensorDry->get();
} else {
return DEACTIVATED_PLANT;
}
}
HomieInternals::SendingPromise& setProperty(const String& property) const {

View File

@ -441,28 +441,36 @@ int determineNextPump(){
bool isLowLight =(solarValue > SOLAR_CHARGE_MIN_VOLTAGE || solarValue < SOLAR_CHARGE_MAX_VOLTAGE);
//FIXME instead of for, use sorted by last activation index to ensure equal runtime?
int pumpToUse = -1;
for(int i=0; i < MAX_PLANTS; i++) {
Plant plant = mPlants[i];
long lastActivation = getLastActivationForPump(i);
long sinceLastActivation = getCurrentTime()-lastActivation;
//this pump is in cooldown skip it and disable low power mode trigger for it
if(mPlants[i].isInCooldown(sinceLastActivation) ){
if(plant.isInCooldown(sinceLastActivation) ){
Serial.printf("%d Skipping due to cooldown\r\n", i);
setMoistureTrigger(i, DEACTIVATED_PLANT);
continue;
}
//skip as it is not low light
if(!isLowLight && mPlants[i].isAllowedOnlyAtLowLight()){
Serial.println("Skipping due to light");
if(!isLowLight && plant.isAllowedOnlyAtLowLight()){
Serial.printf("%d No pump required: due to light\r\n", i);
continue;
}
if(mPlants->isPumpRequired()){
if(plant.isPumpRequired()){
Serial.printf("%d Requested pumping\r\n", i);
return i;
pumpToUse = i;
}
Serial.printf("%d No pump required\r\n", i);
if(plant.isPumpTriggerActive()){
Serial.printf("%d No pump required: disabled trigger %f / %ld\r\n", i, plant.getCurrentMoisture(), plant.getSettingsMoisture());
}else {
Serial.printf("%d No pump required: disabled trigger\r\n", i);
}
}
return -1;
return pumpToUse;
}
/**
@ -658,7 +666,7 @@ void setup() {
* @brief Cyclic call
* Executs the Homie base functionallity or triggers sleeping, if requested.
*/
long nextBlink = 0;
void loop() {
if (!mDeepsleep || mode3Active) {
Homie.loop();
@ -675,7 +683,10 @@ void loop() {
}
/* Toggel Senor LED to visualize mode 3 */
if (mode3Active && (millis() % 100) == 0) {
if(mode3Active){
if (nextBlink < millis()) {
nextBlink = millis() + 500;
digitalWrite(OUTPUT_SENSOR, ! digitalRead(OUTPUT_SENSOR));
}
}
}