fixed wrong indes for pump determination
improved pump status output fixed led blinking in mode3 random
This commit is contained in:
		| @@ -60,9 +60,24 @@ public: | ||||
|      * @return false  | ||||
|      */ | ||||
|     bool isPumpRequired() { | ||||
|          return (this->mSetting->pSensorDry != NULL)  | ||||
|             && (this->moistureRaw.getMedian() > this->mSetting->pSensorDry->get()) | ||||
|             && (this->mSetting->pSensorDry->get() != DEACTIVATED_PLANT);  | ||||
|         bool isDry = getCurrentMoisture() > getSettingsMoisture(); | ||||
|         bool isActive = isPumpTriggerActive(); | ||||
|         return isDry && isActive; | ||||
|     } | ||||
|  | ||||
|     bool isPumpTriggerActive(){ | ||||
|         return this->mSetting->pSensorDry->get() != DEACTIVATED_PLANT; | ||||
|     } | ||||
|  | ||||
|     float getCurrentMoisture(){ | ||||
|         return this->moistureRaw.getMedian(); | ||||
|     } | ||||
|     long getSettingsMoisture(){ | ||||
|         if(this->mSetting->pSensorDry != NULL){ | ||||
|             return this->mSetting->pSensorDry->get(); | ||||
|         } else { | ||||
|             return DEACTIVATED_PLANT; | ||||
|         } | ||||
|     } | ||||
|  | ||||
|     HomieInternals::SendingPromise& setProperty(const String& property) const { | ||||
|   | ||||
| @@ -441,28 +441,36 @@ int determineNextPump(){ | ||||
|   bool isLowLight =(solarValue > SOLAR_CHARGE_MIN_VOLTAGE || solarValue < SOLAR_CHARGE_MAX_VOLTAGE); | ||||
|  | ||||
|   //FIXME instead of for, use sorted by last activation index to ensure equal runtime? | ||||
|  | ||||
|   int pumpToUse = -1; | ||||
|   for(int i=0; i < MAX_PLANTS; i++) { | ||||
|     Plant plant = mPlants[i]; | ||||
|     long lastActivation = getLastActivationForPump(i); | ||||
|     long sinceLastActivation = getCurrentTime()-lastActivation; | ||||
|     //this pump is in cooldown skip it and disable low power mode trigger for it | ||||
|     if(mPlants[i].isInCooldown(sinceLastActivation) ){ | ||||
|     if(plant.isInCooldown(sinceLastActivation) ){ | ||||
|       Serial.printf("%d Skipping due to cooldown\r\n", i); | ||||
|       setMoistureTrigger(i, DEACTIVATED_PLANT); | ||||
|       continue; | ||||
|     } | ||||
|     //skip as it is not low light | ||||
|     if(!isLowLight && mPlants[i].isAllowedOnlyAtLowLight()){ | ||||
|       Serial.println("Skipping due to light"); | ||||
|     if(!isLowLight && plant.isAllowedOnlyAtLowLight()){ | ||||
|       Serial.printf("%d No pump required: due to light\r\n", i); | ||||
|       continue; | ||||
|     } | ||||
|  | ||||
|     if(mPlants->isPumpRequired()){ | ||||
|     if(plant.isPumpRequired()){ | ||||
|       Serial.printf("%d Requested pumping\r\n", i); | ||||
|       return i; | ||||
|       pumpToUse = i; | ||||
|     } | ||||
|     Serial.printf("%d No pump required\r\n", i); | ||||
|     if(plant.isPumpTriggerActive()){ | ||||
|       Serial.printf("%d No pump required: disabled trigger %f / %ld\r\n", i, plant.getCurrentMoisture(), plant.getSettingsMoisture()); | ||||
|     }else { | ||||
|       Serial.printf("%d No pump required: disabled trigger\r\n", i); | ||||
|     } | ||||
|      | ||||
|   } | ||||
|   return -1; | ||||
|   return pumpToUse; | ||||
| } | ||||
|  | ||||
| /** | ||||
| @@ -658,7 +666,7 @@ void setup() { | ||||
|  * @brief Cyclic call | ||||
|  * Executs the Homie base functionallity or triggers sleeping, if requested. | ||||
|  */ | ||||
|  | ||||
| long nextBlink = 0; | ||||
| void loop() { | ||||
|   if (!mDeepsleep || mode3Active) { | ||||
|     Homie.loop(); | ||||
| @@ -675,7 +683,10 @@ void loop() { | ||||
|   } | ||||
|  | ||||
|   /* Toggel Senor LED to visualize mode 3 */ | ||||
|   if (mode3Active && (millis() % 100) == 0) { | ||||
|   if(mode3Active){ | ||||
|     if (nextBlink < millis()) { | ||||
|       nextBlink = millis() + 500; | ||||
|       digitalWrite(OUTPUT_SENSOR, ! digitalRead(OUTPUT_SENSOR)); | ||||
|     } | ||||
|   } | ||||
| } | ||||
|   | ||||
		Reference in New Issue
	