fixed wrong indes for pump determination

improved pump status output
fixed led blinking in  mode3 random
This commit is contained in:
Empire 2020-11-04 21:10:22 +01:00
parent 329a228b2d
commit fb907f9b12
2 changed files with 38 additions and 12 deletions

View File

@ -60,9 +60,24 @@ public:
* @return false * @return false
*/ */
bool isPumpRequired() { bool isPumpRequired() {
return (this->mSetting->pSensorDry != NULL) bool isDry = getCurrentMoisture() > getSettingsMoisture();
&& (this->moistureRaw.getMedian() > this->mSetting->pSensorDry->get()) bool isActive = isPumpTriggerActive();
&& (this->mSetting->pSensorDry->get() != DEACTIVATED_PLANT); return isDry && isActive;
}
bool isPumpTriggerActive(){
return this->mSetting->pSensorDry->get() != DEACTIVATED_PLANT;
}
float getCurrentMoisture(){
return this->moistureRaw.getMedian();
}
long getSettingsMoisture(){
if(this->mSetting->pSensorDry != NULL){
return this->mSetting->pSensorDry->get();
} else {
return DEACTIVATED_PLANT;
}
} }
HomieInternals::SendingPromise& setProperty(const String& property) const { HomieInternals::SendingPromise& setProperty(const String& property) const {

View File

@ -441,28 +441,36 @@ int determineNextPump(){
bool isLowLight =(solarValue > SOLAR_CHARGE_MIN_VOLTAGE || solarValue < SOLAR_CHARGE_MAX_VOLTAGE); bool isLowLight =(solarValue > SOLAR_CHARGE_MIN_VOLTAGE || solarValue < SOLAR_CHARGE_MAX_VOLTAGE);
//FIXME instead of for, use sorted by last activation index to ensure equal runtime? //FIXME instead of for, use sorted by last activation index to ensure equal runtime?
int pumpToUse = -1;
for(int i=0; i < MAX_PLANTS; i++) { for(int i=0; i < MAX_PLANTS; i++) {
Plant plant = mPlants[i];
long lastActivation = getLastActivationForPump(i); long lastActivation = getLastActivationForPump(i);
long sinceLastActivation = getCurrentTime()-lastActivation; long sinceLastActivation = getCurrentTime()-lastActivation;
//this pump is in cooldown skip it and disable low power mode trigger for it //this pump is in cooldown skip it and disable low power mode trigger for it
if(mPlants[i].isInCooldown(sinceLastActivation) ){ if(plant.isInCooldown(sinceLastActivation) ){
Serial.printf("%d Skipping due to cooldown\r\n", i); Serial.printf("%d Skipping due to cooldown\r\n", i);
setMoistureTrigger(i, DEACTIVATED_PLANT); setMoistureTrigger(i, DEACTIVATED_PLANT);
continue; continue;
} }
//skip as it is not low light //skip as it is not low light
if(!isLowLight && mPlants[i].isAllowedOnlyAtLowLight()){ if(!isLowLight && plant.isAllowedOnlyAtLowLight()){
Serial.println("Skipping due to light"); Serial.printf("%d No pump required: due to light\r\n", i);
continue; continue;
} }
if(mPlants->isPumpRequired()){ if(plant.isPumpRequired()){
Serial.printf("%d Requested pumping\r\n", i); Serial.printf("%d Requested pumping\r\n", i);
return i; pumpToUse = i;
} }
Serial.printf("%d No pump required\r\n", i); if(plant.isPumpTriggerActive()){
Serial.printf("%d No pump required: disabled trigger %f / %ld\r\n", i, plant.getCurrentMoisture(), plant.getSettingsMoisture());
}else {
Serial.printf("%d No pump required: disabled trigger\r\n", i);
} }
return -1;
}
return pumpToUse;
} }
/** /**
@ -658,7 +666,7 @@ void setup() {
* @brief Cyclic call * @brief Cyclic call
* Executs the Homie base functionallity or triggers sleeping, if requested. * Executs the Homie base functionallity or triggers sleeping, if requested.
*/ */
long nextBlink = 0;
void loop() { void loop() {
if (!mDeepsleep || mode3Active) { if (!mDeepsleep || mode3Active) {
Homie.loop(); Homie.loop();
@ -675,7 +683,10 @@ void loop() {
} }
/* Toggel Senor LED to visualize mode 3 */ /* Toggel Senor LED to visualize mode 3 */
if (mode3Active && (millis() % 100) == 0) { if(mode3Active){
if (nextBlink < millis()) {
nextBlink = millis() + 500;
digitalWrite(OUTPUT_SENSOR, ! digitalRead(OUTPUT_SENSOR)); digitalWrite(OUTPUT_SENSOR, ! digitalRead(OUTPUT_SENSOR));
} }
}
} }