file write test
This commit is contained in:
		| @@ -1,5 +1,6 @@ | ||||
| nvs,      data, nvs,     0x9000,  0x4000, | ||||
| otadata,  data, ota,     0xd000,  0x2000, | ||||
| phy_init, data, phy,     0xf000,  0x1000, | ||||
| ota_0,    app,  ota_0,   0x10000, 0x180000, | ||||
| ota_1,    app,  ota_1,   0x190000, 0x180000, | ||||
| nvs,      data, nvs,     ,        16k, | ||||
| otadata,  data, ota,     ,        8k, | ||||
| phy_init, data, phy,     ,        4k, | ||||
| factory,  app,  ota_0,   ,        1792K, | ||||
| ota_1,    app,  ota_1,   ,        1792K, | ||||
| storage,  data, spiffs,  ,        400K,  | ||||
| 
 | 
							
								
								
									
										280
									
								
								rust/src/main.rs
									
									
									
									
									
								
							
							
						
						
									
										280
									
								
								rust/src/main.rs
									
									
									
									
									
								
							| @@ -1,20 +1,25 @@ | ||||
| use std::{fs::File, io::Write}; | ||||
| use std::{ | ||||
|     ffi::CString, | ||||
|     fs::File, | ||||
|     io::{Read, Write}, | ||||
|     str::from_utf8, | ||||
| }; | ||||
|  | ||||
| use chrono::{Datelike, Timelike, NaiveDateTime}; | ||||
| use chrono::{Datelike, NaiveDateTime, Timelike}; | ||||
|  | ||||
| use anyhow::{Context, Result}; | ||||
| use chrono_tz::Europe::Berlin; | ||||
| use esp_idf_hal::delay::Delay; | ||||
| use esp_idf_svc::http::server::EspHttpServer; | ||||
| use plant_hal::{PlantCtrlBoardInteraction, PlantHal, CreatePlantHal, PLANT_COUNT}; | ||||
| use anyhow::{Context, Result}; | ||||
| use plant_hal::{CreatePlantHal, PlantCtrlBoardInteraction, PlantHal, PLANT_COUNT}; | ||||
| use webserver::webserver::httpd; | ||||
| pub mod plant_hal; | ||||
| mod config; | ||||
| pub mod plant_hal; | ||||
| mod webserver { | ||||
|     pub mod webserver; | ||||
| } | ||||
|  | ||||
| fn main() -> Result<()>{ | ||||
| fn main() -> Result<()> { | ||||
|     // It is necessary to call this function once. Otherwise some patches to the runtime | ||||
|     // implemented by esp-idf-sys might not link properly. See https://github.com/esp-rs/esp-idf-template/issues/71 | ||||
|     esp_idf_svc::sys::link_patches(); | ||||
| @@ -26,102 +31,126 @@ fn main() -> Result<()>{ | ||||
|  | ||||
|     let git_hash = env!("VERGEN_GIT_DESCRIBE"); | ||||
|     println!("Version useing git has {}", git_hash); | ||||
|      | ||||
|  | ||||
|     let mut board = PlantHal::create()?;      | ||||
|      | ||||
|     println!("Board hal init"); | ||||
|       | ||||
|     let time = board.time(); | ||||
|     let mut cur = match time { | ||||
|         Ok(cur) => cur, | ||||
|         Err(err) => { | ||||
|             log::error!("time error {}", err); | ||||
|             NaiveDateTime::from_timestamp_millis(0).unwrap().and_utc() | ||||
|         let mut board = PlantHal::create()?; | ||||
|  | ||||
|         println!("Board hal init"); | ||||
|  | ||||
|         let time = board.time(); | ||||
|         let mut cur = match time { | ||||
|             Ok(cur) => cur, | ||||
|             Err(err) => { | ||||
|                 log::error!("time error {}", err); | ||||
|                 NaiveDateTime::from_timestamp_millis(0).unwrap().and_utc() | ||||
|             } | ||||
|         }; | ||||
|         //check if we know the time current > 2020 | ||||
|         if cur.year() < 2020 { | ||||
|             if board.is_day() { | ||||
|                 //assume TZ safe times ;) | ||||
|                 cur = *cur.with_hour(15).get_or_insert(cur); | ||||
|             } else { | ||||
|                 cur = *cur.with_hour(3).get_or_insert(cur); | ||||
|             } | ||||
|         } | ||||
|     }; | ||||
|     //check if we know the time current > 2020 | ||||
|     if cur.year() < 2020 { | ||||
|         if board.is_day() { | ||||
|             //assume TZ safe times ;) | ||||
|             cur = *cur.with_hour(15).get_or_insert(cur); | ||||
|         } else { | ||||
|             cur = *cur.with_hour(3).get_or_insert(cur); | ||||
|         } | ||||
|     } | ||||
|  | ||||
|     println!("cur is {}", cur); | ||||
|         println!("cur is {}", cur); | ||||
|  | ||||
|  | ||||
|      | ||||
|  | ||||
|     //continous/interrupt? | ||||
|         //check if boot button is pressed, if longer than 5s delete config and reboot into config mode | ||||
|  | ||||
|  | ||||
|     let config = board.get_config(); | ||||
|     match config { | ||||
|         Ok(conf) => { | ||||
|              | ||||
|         }, | ||||
|         Err(err) => { | ||||
|              | ||||
|         }, | ||||
|     } | ||||
|         //continous/interrupt? | ||||
|             //check if boot button is pressed, if longer than 5s delete config and reboot into config mode | ||||
|  | ||||
| //    let proceed = config.unwrap(); | ||||
|      | ||||
|     //check if we have a config file | ||||
|         // if not found or parsing error -> error very fast blink general fault | ||||
|             //if this happens after a firmeware upgrade (check image state), mark as invalid | ||||
|                 //blink general fault error_reading_config_after_upgrade, reboot after | ||||
|             // open accesspoint with webserver for wlan mqtt setup | ||||
|                 //blink general fault error_no_config_after_upgrade | ||||
|                     //once config is set store it and reboot | ||||
|  | ||||
|     //if proceed.tank_sensor_enabled() { | ||||
|          | ||||
|     //} | ||||
|     //is tank sensor enabled in config? | ||||
|         //measure tank level (without wifi due to interference) | ||||
|         //TODO this should be a result// detect invalid measurement value | ||||
|         let tank_value = board.tank_sensor_mv(); | ||||
|         match tank_value { | ||||
|             Ok(tank_raw) => { | ||||
|                 println!("Tank sensor returned {}", tank_raw); | ||||
|         let config = board.get_config(); | ||||
|         match config { | ||||
|             Ok(conf) => { | ||||
|  | ||||
|             }, | ||||
|             Err(_) => { | ||||
|                 //if not possible value, blink general fault error_tank_sensor_fault | ||||
|                 board.general_fault(true); | ||||
|                 //set general fault persistent | ||||
|                 //set tank sensor state to fault | ||||
|             Err(err) => { | ||||
|  | ||||
|             }, | ||||
|         } | ||||
|              | ||||
|  | ||||
|     //measure each plant moisture | ||||
|     let mut initial_measurements_a: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; | ||||
|     let mut initial_measurements_b: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; | ||||
|     let mut initial_measurements_p: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; | ||||
|     for plant in 0..PLANT_COUNT { | ||||
|         initial_measurements_a[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::A)?; | ||||
|         initial_measurements_b[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::B)?; | ||||
|         initial_measurements_p[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::PUMP)?; | ||||
|     //    let proceed = config.unwrap(); | ||||
|  | ||||
|         //check if we have a config file | ||||
|             // if not found or parsing error -> error very fast blink general fault | ||||
|                 //if this happens after a firmeware upgrade (check image state), mark as invalid | ||||
|                     //blink general fault error_reading_config_after_upgrade, reboot after | ||||
|                 // open accesspoint with webserver for wlan mqtt setup | ||||
|                     //blink general fault error_no_config_after_upgrade | ||||
|                         //once config is set store it and reboot | ||||
|  | ||||
|         //if proceed.tank_sensor_enabled() { | ||||
|  | ||||
|         //} | ||||
|         //is tank sensor enabled in config? | ||||
|             //measure tank level (without wifi due to interference) | ||||
|             //TODO this should be a result// detect invalid measurement value | ||||
|             let tank_value = board.tank_sensor_mv(); | ||||
|             match tank_value { | ||||
|                 Ok(tank_raw) => { | ||||
|                     println!("Tank sensor returned {}", tank_raw); | ||||
|                 }, | ||||
|                 Err(_) => { | ||||
|                     //if not possible value, blink general fault error_tank_sensor_fault | ||||
|                     board.general_fault(true); | ||||
|                     //set general fault persistent | ||||
|                     //set tank sensor state to fault | ||||
|                 }, | ||||
|             } | ||||
|  | ||||
|  | ||||
|         //measure each plant moisture | ||||
|         let mut initial_measurements_a: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; | ||||
|         let mut initial_measurements_b: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; | ||||
|         let mut initial_measurements_p: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; | ||||
|         for plant in 0..PLANT_COUNT { | ||||
|             initial_measurements_a[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::A)?; | ||||
|             initial_measurements_b[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::B)?; | ||||
|             initial_measurements_p[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::PUMP)?; | ||||
|         } | ||||
|  | ||||
|         //match board.wifi("C3MA", Some("chaosimquadrat"), 10000) { | ||||
|         //    Ok(_) => println!("online mode"), | ||||
|         //    Err(_) => { | ||||
|  | ||||
|     //            println!("Offline mode"); | ||||
|             //}, | ||||
|         //} | ||||
|         //try connect wifi and do mqtt roundtrip | ||||
|             // if no wifi, set general fault persistent | ||||
|                 //if no mqtt, set general fault persistent | ||||
|                  | ||||
|     unsafe { | ||||
|         let base_path = CString::new("/spiffs").unwrap(); | ||||
|         let storage = CString::new("storage").unwrap(); | ||||
|  | ||||
|         let conf = esp_idf_sys::esp_vfs_spiffs_conf_t { | ||||
|             base_path: base_path.as_ptr(), | ||||
|             partition_label: storage.as_ptr(), | ||||
|             max_files: 5, | ||||
|             format_if_mount_failed: true, | ||||
|         }; | ||||
|  | ||||
|         let mount = esp_idf_sys::esp_vfs_spiffs_register(&conf); | ||||
|         println!("Mount returned {}", mount); | ||||
|     } | ||||
|     println!("writing"); | ||||
|     let mut config_file = File::create("/spiffs/config.cfg")?; | ||||
|     config_file.write_all("test stuff".as_bytes())?; | ||||
|     config_file.flush()?; | ||||
|     println!("Reading"); | ||||
|     let mut cfg = File::open("/spiffs/config.cfg")?; | ||||
|     let mut data: [u8; 512] = [0; 512]; | ||||
|     let read = cfg.read(&mut data)?; | ||||
|     println!("Read file {}", from_utf8(&data[0..read])?); | ||||
|  | ||||
|     match board.wifi("C3MA", Some("chaosimquadrat"), 10000) { | ||||
|         Ok(_) => println!("online mode"), | ||||
|         Err(_) => { | ||||
|  | ||||
|             println!("Offline mode"); | ||||
|         }, | ||||
|     } | ||||
|     //try connect wifi and do mqtt roundtrip | ||||
|         // if no wifi, set general fault persistent | ||||
|             //if no mqtt, set general fault persistent | ||||
|  | ||||
|      | ||||
|     match board.sntp(1000*120) { | ||||
|     /*  | ||||
|     match board.sntp(1000 * 120) { | ||||
|         Ok(new_time) => cur = new_time, | ||||
|         Err(err) => { | ||||
|             println!("sntp error: {}", err); | ||||
| @@ -131,62 +160,57 @@ fn main() -> Result<()>{ | ||||
|     let europe_time = cur.with_timezone(&Berlin); | ||||
|     println!("Running logic at europe/berlin {}", europe_time); | ||||
|  | ||||
|  | ||||
|  | ||||
|     //if config battery mode | ||||
|         //read battery level | ||||
|             //if not possible set general fault persistent, but do continue | ||||
|     //read battery level | ||||
|     //if not possible set general fault persistent, but do continue | ||||
|     //else | ||||
|         //assume 12v and max capacity | ||||
|     //assume 12v and max capacity | ||||
|  | ||||
|     //if tank sensor is enabled | ||||
|         //if tank sensor fault abort if config require is set | ||||
|         //check if water is > minimum allowed || fault | ||||
|             //if not, set all plants requiring water to persistent fault | ||||
|     //if tank sensor fault abort if config require is set | ||||
|     //check if water is > minimum allowed || fault | ||||
|     //if not, set all plants requiring water to persistent fault | ||||
|  | ||||
|     //for each plant | ||||
|         //check if moisture is < target | ||||
|             //state  += dry | ||||
|             //check if in cooldown | ||||
|                 //state += cooldown | ||||
|                 //check if consecutive pumps > limit | ||||
|                     //state += notworking | ||||
|                     //set plant fault persistent | ||||
|              | ||||
|             //pump one cycle | ||||
|             // set last pump time to now | ||||
|                 //during pump state += active | ||||
|             //after pump check if Pump moisture value is increased by config delta x | ||||
|                 // state -= active | ||||
|                 // state += cooldown | ||||
|                 // if not set plant error persistent fault     | ||||
|                 // state += notworking | ||||
|             //set consecutive pumps+=1 | ||||
|      | ||||
|     //check if moisture is < target | ||||
|     //state  += dry | ||||
|     //check if in cooldown | ||||
|     //state += cooldown | ||||
|     //check if consecutive pumps > limit | ||||
|     //state += notworking | ||||
|     //set plant fault persistent | ||||
|  | ||||
|     //pump one cycle | ||||
|     // set last pump time to now | ||||
|     //during pump state += active | ||||
|     //after pump check if Pump moisture value is increased by config delta x | ||||
|     // state -= active | ||||
|     // state += cooldown | ||||
|     // if not set plant error persistent fault | ||||
|     // state += notworking | ||||
|     //set consecutive pumps+=1 | ||||
|  | ||||
|     //check if during light time | ||||
|         //lightstate += out of worktime | ||||
|     //lightstate += out of worktime | ||||
|     //check battery level | ||||
|         //lightstate += battery empty | ||||
|     //lightstate += battery empty | ||||
|     //check solar level if config requires | ||||
|         //lightstate += stillday | ||||
|     //lightstate += stillday | ||||
|     //if no preventing lightstate, enable light | ||||
|         //lightstate = active | ||||
|      | ||||
|  | ||||
|         //keep webserver in scope | ||||
|         let webserver = httpd(true); | ||||
|         let delay = Delay::new_default(); | ||||
|         loop { | ||||
|             //let freertos do shit | ||||
|             delay.delay_ms(1001); | ||||
|         } | ||||
|          | ||||
|         return Ok(()) | ||||
|     //lightstate = active | ||||
|  | ||||
|     //keep webserver in scope | ||||
|     let webserver = httpd(true); | ||||
|     let delay = Delay::new_default(); | ||||
|     loop { | ||||
|         //let freertos do shit | ||||
|         delay.delay_ms(1001); | ||||
|     } | ||||
| */ | ||||
|     return Ok(()); | ||||
| } | ||||
|  | ||||
| //error codes | ||||
| //error_reading_config_after_upgrade | ||||
| //error_no_config_after_upgrade | ||||
| //error_tank_sensor_fault | ||||
| //error_tank_sensor_fault | ||||
|   | ||||
		Reference in New Issue
	