Publish only temperatur values, if a sensor was found
This commit is contained in:
parent
6ba2f92fa7
commit
e094221298
@ -26,7 +26,7 @@ const unsigned long TEMPREADCYCLE = 30000; /**< Check temperature all half minut
|
||||
#define SOLAR4SENSORS 6.0f
|
||||
#define TEMP_INIT_VALUE -999.0f
|
||||
#define TEMP_MAX_VALUE 85.0f
|
||||
#define HalfHour 60
|
||||
#define HalfHour 60
|
||||
|
||||
/********************* non volatile enable after deepsleep *******************************/
|
||||
|
||||
@ -208,10 +208,15 @@ void mode2MQTT(){
|
||||
sensorSolar.setProperty("percent").send(String((100 * solarRawSensor.getAverage() ) / 4095));
|
||||
sensorSolar.setProperty("volt").send( String(getSolarVoltage()) );
|
||||
|
||||
|
||||
float t1 = temp1.getMedian();
|
||||
if (t1 != NAN) {
|
||||
sensorTemp.setProperty("control").send( String(t1));
|
||||
}
|
||||
float t2 = temp2.getMedian();
|
||||
sensorTemp.setProperty("control").send( String(t1));
|
||||
sensorTemp.setProperty("temp").send( String(t2));
|
||||
if (t2 != NAN) {
|
||||
sensorTemp.setProperty("temp").send( String(t2));
|
||||
}
|
||||
|
||||
//give mqtt time, use via publish callback instead?
|
||||
delay(100);
|
||||
@ -364,14 +369,18 @@ void readSensors() {
|
||||
|
||||
|
||||
/* Required to read the temperature once */
|
||||
float temp[2] = {0, 0};
|
||||
float temp[2] = {TEMP_MAX_VALUE, TEMP_MAX_VALUE};
|
||||
float* pFloat = temp;
|
||||
if (dallas.readAllTemperatures(pFloat, 2) > 0) {
|
||||
int sensors = dallas.readAllTemperatures(pFloat, 2);
|
||||
if (sensors > 0) {
|
||||
Serial << "t1: " << String(temp[0]) << endl;
|
||||
Serial << "t2: " << String(temp[1]) << endl;
|
||||
temp1.add(temp[0]);
|
||||
}
|
||||
temp1.add(temp[0]);
|
||||
temp2.add(temp[1]);
|
||||
if (sensors > 1) {
|
||||
Serial << "t2: " << String(temp[1]) << endl;
|
||||
temp2.add(temp[1]);
|
||||
}
|
||||
|
||||
|
||||
/* Use the Ultrasonic sensor to measure waterLevel */
|
||||
|
||||
@ -408,8 +417,9 @@ void onHomieEvent(const HomieEvent& event) {
|
||||
esp_deep_sleep_start();
|
||||
break;
|
||||
case HomieEventType::OTA_STARTED:
|
||||
Homie.getLogger() << "OTA started" << endl;
|
||||
digitalWrite(OUTPUT_SENSOR, HIGH);
|
||||
digitalWrite(OUTPUT_PUMP, LOW);
|
||||
digitalWrite(OUTPUT_PUMP, HIGH);
|
||||
gpio_hold_dis(GPIO_NUM_13); //pump pwr
|
||||
gpio_deep_sleep_hold_dis();
|
||||
for (int i=0; i < MAX_PLANTS; i++) {
|
||||
@ -418,6 +428,7 @@ void onHomieEvent(const HomieEvent& event) {
|
||||
mode3Active=true;
|
||||
break;
|
||||
case HomieEventType::OTA_SUCCESSFUL:
|
||||
Homie.getLogger() << "OTA successfull" << endl;
|
||||
digitalWrite(OUTPUT_SENSOR, LOW);
|
||||
digitalWrite(OUTPUT_PUMP, LOW);
|
||||
ESP.restart();
|
||||
@ -588,7 +599,7 @@ void mode2(){
|
||||
|
||||
/* Jump into Mode 3, if not configured */
|
||||
if (!mConfigured) {
|
||||
Serial.println("m3");
|
||||
Serial.println("==== Mode 3 ====");
|
||||
mode3Active = true;
|
||||
}
|
||||
}
|
||||
|
Loading…