config reduced, config json parser memory adjusted
This commit is contained in:
@@ -78,7 +78,7 @@
|
||||
/** \addtogroup Configuration
|
||||
* @{
|
||||
*/
|
||||
#define FIRMWARE_VERSION "sw 1.2 hw 0.9"
|
||||
#define FIRMWARE_VERSION "sw 1.3 hw 0.10"
|
||||
|
||||
#define MOIST_SENSOR_MAX_ADC (85 * 4095 / 100)
|
||||
#define MOIST_SENSOR_MIN_ADC (25 * 4095 / 100)
|
||||
@@ -94,7 +94,8 @@
|
||||
#define SOLAR_CHARGE_MAX_VOLTAGE 9 /**< Sun is shining (noon) */
|
||||
#define VOLT_MAX_BATT 4.2f
|
||||
|
||||
#define MAX_CONFIG_SETTING_ITEMS 50 /**< Parameter, that can be configured in Homie */
|
||||
#define MAX_CONFIG_SETTING_ITEMS 100 /**< Parameter, that can be configured in Homie */
|
||||
#define MAX_JSON_CONFIG_FILE_SIZE_CUSTOM 2500
|
||||
|
||||
#define TEMPERATUR_TIMEOUT 3000 /**< 3 Seconds timeout for the temperatur sensors */
|
||||
#define DS18B20_RESOLUTION 9 /**< 9bit temperature resolution -> 0.5°C steps */
|
||||
|
@@ -65,16 +65,16 @@ HomieNode stayAlive("stay", "alive", "alive"); /**< Necessary for Mqtt Active C
|
||||
* General settings for the controller
|
||||
* @{
|
||||
*/
|
||||
HomieSetting<long> deepSleepTime("deepsleep", "time in seconds to sleep");
|
||||
HomieSetting<long> deepSleepTime("sleep", "time in seconds to sleep");
|
||||
HomieSetting<long> deepSleepNightTime("nightsleep", "time in seconds to sleep (0 uses same setting: deepsleep at night, too)");
|
||||
HomieSetting<long> wateringDeepSleep("pumpdeepsleep", "time seconds to sleep, while a pump is running");
|
||||
HomieSetting<long> wateringDeepSleep("pumpsleep", "time seconds to sleep, while a pump is running");
|
||||
|
||||
HomieSetting<long> waterLevelMax("watermaxlevel", "distance (mm) at maximum water level");
|
||||
HomieSetting<long> waterLevelMin("waterminlevel", "distance (mm) at minimum water level (pumps still covered)");
|
||||
HomieSetting<long> waterLevelWarn("waterlevelwarn", "warn (mm) if below this water level %");
|
||||
HomieSetting<long> waterLevelVol("waterVolume", "(ml) between minimum and maximum");
|
||||
HomieSetting<const char *> lipoSensorAddr("lipoTempAddr", "1wire address for lipo temperature sensor");
|
||||
HomieSetting<const char *> waterSensorAddr("waterTempIndex", "1wire address for water temperature sensor");
|
||||
HomieSetting<long> waterLevelMax("tankmax", "distance (mm) at maximum water level");
|
||||
HomieSetting<long> waterLevelMin("tankmin", "distance (mm) at minimum water level (pumps still covered)");
|
||||
HomieSetting<long> waterLevelWarn("tankwarn", "warn (mm) if below this water level %");
|
||||
HomieSetting<long> waterLevelVol("tankVolume", "(ml) between minimum and maximum");
|
||||
HomieSetting<const char *> lipoSensorAddr("lipoDSAddr", "1wire address for lipo temperature sensor");
|
||||
HomieSetting<const char *> waterSensorAddr("tankDSAddr", "1wire address for water temperature sensor");
|
||||
HomieSetting<const char *> ntpServer("ntpServer", "NTP server (pool.ntp.org as default)");
|
||||
|
||||
/**
|
||||
@@ -88,11 +88,11 @@ HomieSetting<const char *> ntpServer("ntpServer", "NTP server (pool.ntp.org as d
|
||||
**/
|
||||
|
||||
#define GENERATE_PLANT(plant, strplant) \
|
||||
HomieSetting<long> mSensorDry##plant = HomieSetting<long>("moistdry" strplant, "Plant " strplant "- Moist sensor dry threshold"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("rangehourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("rangehourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
|
||||
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("onlyWhenLowLightZ" strplant, "Plant" strplant " - Enable the Pump only, when there is no sunlight"); \
|
||||
HomieSetting<long> mPumpCooldownInHours##plant = HomieSetting<long>("cooldownpump" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
|
||||
HomieSetting<long> mSensorDry##plant = HomieSetting<long>("dry" strplant, "Plant " strplant "- Moist sensor dry threshold"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("hourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("hourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
|
||||
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("lowLight" strplant, "Plant" strplant " - Enable the Pump only, when there is no sunlight"); \
|
||||
HomieSetting<long> mPumpCooldownInHours##plant = HomieSetting<long>("delay" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
|
||||
PlantSettings_t mSetting##plant = {&mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInHours##plant}; \
|
||||
/**< Generate all settings for one plant \
|
||||
* \
|
||||
|
Reference in New Issue
Block a user