This commit is contained in:
Empire 2023-11-20 02:24:14 +01:00
parent 17db1b8a45
commit 825d389a8c

View File

@ -2,6 +2,7 @@ use chrono::Utc;
use embedded_hal::digital::v1_compat::OldOutputPin;
use esp_idf_hal::adc::config::Config;
use esp_idf_hal::adc::{AdcDriver, AdcChannelDriver, attenuation};
use esp_idf_hal::reset::ResetReason;
use shift_register_driver::sipo::{ShiftRegister24, ShiftRegisterPin};
use esp_idf_hal::gpio::PinDriver;
use esp_idf_hal::prelude::Peripherals;
@ -30,32 +31,32 @@ struct BatteryState {
state_health_percent: u8
}
trait PlantCtrlBoardInteraction{
fn battery_state() -> BatteryState;
fn battery_state(&self,) -> BatteryState;
fn is_day() -> bool;
fn water_temperature_c() -> u16;
fn tank_sensor_mv() -> u16;
fn set_low_voltage_in_cycle();
fn clear_low_voltage_in_cycle();
fn low_voltage_in_cycle(low_voltage:bool);
fn is_day(&self,) -> bool;
fn water_temperature_c(&self,) -> u16;
fn tank_sensor_mv(&self,) -> u16;
fn set_low_voltage_in_cycle(&self,);
fn clear_low_voltage_in_cycle(&self,);
fn low_voltage_in_cycle(&self) -> bool;
fn any_pump(&self, enabled:bool);
//keep state during deepsleep
fn light(enable:bool);
fn light(&self,enable:bool);
fn plant_count() -> i8;
fn measure_moisture_b_hz(plant:i8) -> i16;
fn measure_moisture_a_hz(plant:i8) -> i16;
fn measure_moisture_p_hz(plant:i8) -> i16;
fn pump(plant:i8, enable:bool);
fn last_pump_time(plant:i8) -> chrono::DateTime<Utc>;
fn store_last_pump_time(plant:i8, time: chrono::DateTime<Utc>);
fn store_consecutive_pump_count(plant:i8, count:i16);
fn consecutive_pump_count(plant:i8) -> i16;
fn plant_count(&self,) -> i8;
fn measure_moisture_b_hz(&self,plant:i8) -> i16;
fn measure_moisture_a_hz(&self,plant:i8) -> i16;
fn measure_moisture_p_hz(&self,plant:i8) -> i16;
fn pump(&self,plant:i8, enable:bool);
fn last_pump_time(&self,plant:i8) -> chrono::DateTime<Utc>;
fn store_last_pump_time(&self,plant:i8, time: chrono::DateTime<Utc>);
fn store_consecutive_pump_count(&self,plant:i8, count:i16);
fn consecutive_pump_count(&self,plant:i8) -> i16;
//keep state during deepsleep
fn fault(plant:i8, enable:bool);
fn fault(&self,plant:i8, enable:bool);
fn default() -> Self;
}
@ -95,53 +96,85 @@ impl PlantCtrlBoardInteraction for PlantCtrlBoard {
Self { dummy: 12 }
}
fn plant_count() -> i8 {
fn battery_state(&self,) -> BatteryState {
todo!()
}
fn fault(plant:i8, state:bool) {
fn is_day(&self,) -> bool {
todo!()
}
fn pump(plant:i8, state:bool) {
fn water_temperature_c(&self,) -> u16 {
todo!()
}
fn battery_state() -> BatteryState {
fn tank_sensor_mv(&self,) -> u16 {
todo!()
}
fn is_day() -> bool {
fn set_low_voltage_in_cycle(&self,) {
unsafe {
LOW_VOLTAGE_DETECTED = true;
}
}
fn clear_low_voltage_in_cycle(&self,) {
unsafe {
LOW_VOLTAGE_DETECTED = false;
}
}
fn light(&self,enable:bool) {
todo!()
}
fn water_temperature_c() -> u16 {
fn plant_count(&self,) -> i8 {
todo!()
}
fn tank_sensor_mv() -> u16 {
fn measure_moisture_b_hz(&self,plant:i8) -> i16 {
todo!()
}
fn light(enable:bool) {
fn measure_moisture_a_hz(&self,plant:i8) -> i16 {
todo!()
}
fn measure_moisture_b_hz(plant:i8) -> i16 {
fn measure_moisture_p_hz(&self,plant:i8) -> i16 {
todo!()
}
fn measure_moisture_a_hz(plant:i8) -> i16 {
fn pump(&self,plant:i8, enable:bool) {
todo!()
}
fn measure_moisture_p_hz(plant:i8) -> i16 {
fn last_pump_time(&self,plant:i8) -> chrono::DateTime<Utc> {
todo!()
}
fn last_watering_time(plant:i8) -> chrono::DateTime<Utc> {
fn store_last_pump_time(&self,plant:i8, time: chrono::DateTime<Utc>) {
todo!()
}
fn store_consecutive_pump_count(&self,plant:i8, count:i16) {
todo!()
}
fn consecutive_pump_count(&self,plant:i8) -> i16 {
todo!()
}
fn fault(&self,plant:i8, enable:bool) {
todo!()
}
fn low_voltage_in_cycle(&self) -> bool {
unsafe {
return LOW_VOLTAGE_DETECTED;
}
}
}
@ -161,6 +194,53 @@ fn main() {
log::info!("Hello, world!");
let reasons = ResetReason::get();
//init,reset rtc memory depending on cause
let board = PlantCtrlBoard::default();
//check if we know the time current > 2020
//if failed assume its 1.1.1970
//12:00 if solar reports day
//00:00 if solar repors night
//check if we have a config file
// if not found or parsing error -> error very fast blink general fault
//if this happens after a firmeware upgrade (check image state), mark as invalid
//blink general fault error_reading_config_after_upgrade, reboot after
// open accesspoint with webserver for wlan mqtt setup
//blink general fault error_no_config_after_upgrade
//once config is set store it and reboot
//is tank sensor enabled in config?
//measure tank level (without wifi due to interference)
//if not possible value, blink general fault error_tank_sensor_fault
//set general fault persistent
//set tank sensor state to fault
//try connect wifi and do mqtt roundtrip
// if no wifi, set general fault persistent
//if no mqtt, set general fault persistent
//measure each plant moisture
//check which plants need to be watered
//()
//if tank sensor is enabled
//if tank sensor fault abort if config require is set
//check if water is > minimum allowed || fault
//if not, set all plants requiring water to persistent fault
// pump water for first plant update last water timestamp
// wait for config time per plant
//
}
//error codes
//error_reading_config_after_upgrade
//error_no_config_after_upgrade
//error_tank_sensor_fault