adjust folder to be shorter
This commit is contained in:
parent
2092354bc9
commit
17db1b8a45
@ -1,79 +0,0 @@
|
||||
use embedded_hal::digital::v1_compat::OldOutputPin;
|
||||
use shift_register_driver::sipo::{ShiftRegister24, ShiftRegisterPin};
|
||||
use esp_idf_hal::gpio::{PinDriver};
|
||||
use esp_idf_hal::prelude::Peripherals;
|
||||
use dummy_pin::DummyPin;
|
||||
use embedded_hal::digital::v2::OutputPin;
|
||||
|
||||
#[macro_use]
|
||||
extern crate shift_register_driver;
|
||||
|
||||
trait PlantCtrlBoardInteraction{
|
||||
fn measure_moisture() -> i16;
|
||||
fn default() -> Self;
|
||||
}
|
||||
|
||||
trait Plant{
|
||||
fn setPump(pump:bool);
|
||||
|
||||
|
||||
}
|
||||
|
||||
struct PlantHal<'d>{
|
||||
pump:ShiftRegisterPin<'d>
|
||||
}
|
||||
|
||||
struct PlantCtrlBoard{
|
||||
dummy:i32
|
||||
}
|
||||
|
||||
impl PlantCtrlBoardInteraction for PlantCtrlBoard {
|
||||
fn measure_moisture() -> i16 {
|
||||
//pcnr here
|
||||
return 1_i16;
|
||||
}
|
||||
|
||||
|
||||
fn default() -> Self {
|
||||
let peripherals = Peripherals::take().unwrap();
|
||||
|
||||
let clock = OldOutputPin::from(PinDriver::output(peripherals.pins.gpio21).unwrap());
|
||||
let latch = OldOutputPin::from(PinDriver::output(peripherals.pins.gpio22).unwrap());
|
||||
let data = OldOutputPin::from(PinDriver::output(peripherals.pins.gpio19).unwrap());
|
||||
|
||||
|
||||
let shift_register = ShiftRegister24::new(clock, latch, data);
|
||||
let registerOutput = shift_register.decompose();
|
||||
|
||||
|
||||
|
||||
Self { dummy: 12 }
|
||||
}
|
||||
}
|
||||
|
||||
const PLANT_COUNT:usize = 8;
|
||||
#[link_section = ".rtc.data"]
|
||||
static mut LAST_WATERING_TIMESTAMP: [u64; PLANT_COUNT] = [0; PLANT_COUNT];
|
||||
#[link_section = ".rtc.data"]
|
||||
static mut CONSECUTIVE_WATERING_PLANT: [u64; PLANT_COUNT] = [0; PLANT_COUNT];
|
||||
#[link_section = ".rtc.data"]
|
||||
static mut LOW_VOLTAGE_DETECTED:bool = false;
|
||||
|
||||
|
||||
|
||||
|
||||
fn main() {
|
||||
|
||||
// It is necessary to call this function once. Otherwise some patches to the runtime
|
||||
// implemented by esp-idf-sys might not link properly. See https://github.com/esp-rs/esp-idf-template/issues/71
|
||||
esp_idf_svc::sys::link_patches();
|
||||
|
||||
// Bind the log crate to the ESP Logging facilities
|
||||
esp_idf_svc::log::EspLogger::initialize_default();
|
||||
|
||||
log::info!("Hello, world!");
|
||||
|
||||
|
||||
let board = PlantCtrlBoard::default();
|
||||
|
||||
}
|
166
rust/src/main.rs
Normal file
166
rust/src/main.rs
Normal file
@ -0,0 +1,166 @@
|
||||
use chrono::Utc;
|
||||
use embedded_hal::digital::v1_compat::OldOutputPin;
|
||||
use esp_idf_hal::adc::config::Config;
|
||||
use esp_idf_hal::adc::{AdcDriver, AdcChannelDriver, attenuation};
|
||||
use shift_register_driver::sipo::{ShiftRegister24, ShiftRegisterPin};
|
||||
use esp_idf_hal::gpio::PinDriver;
|
||||
use esp_idf_hal::prelude::Peripherals;
|
||||
|
||||
const PLANT_COUNT:usize = 8;
|
||||
#[link_section = ".rtc.data"]
|
||||
static mut LAST_WATERING_TIMESTAMP: [u64; PLANT_COUNT] = [0; PLANT_COUNT];
|
||||
#[link_section = ".rtc.data"]
|
||||
static mut CONSECUTIVE_WATERING_PLANT: [u64; PLANT_COUNT] = [0; PLANT_COUNT];
|
||||
#[link_section = ".rtc.data"]
|
||||
static mut LOW_VOLTAGE_DETECTED:bool = false;
|
||||
|
||||
struct BatteryState {
|
||||
state_charge_percent: u8,
|
||||
max_error_percent: u8,
|
||||
remaining_milli_ampere_hour: u32,
|
||||
max_milli_ampere_hour: u32,
|
||||
design_milli_ampere_hour:u32,
|
||||
voltage_milli_volt: u16,
|
||||
average_current_milli_ampere: u16,
|
||||
temperature_tenth_kelvin: u32,
|
||||
average_time_to_empty_minute: u16,
|
||||
average_time_to_full_minute: u16,
|
||||
average_discharge_power_cycle_milli_watt: u16,
|
||||
cycle_count: u16,
|
||||
state_health_percent: u8
|
||||
}
|
||||
trait PlantCtrlBoardInteraction{
|
||||
fn battery_state() -> BatteryState;
|
||||
|
||||
fn is_day() -> bool;
|
||||
fn water_temperature_c() -> u16;
|
||||
fn tank_sensor_mv() -> u16;
|
||||
|
||||
fn set_low_voltage_in_cycle();
|
||||
fn clear_low_voltage_in_cycle();
|
||||
fn low_voltage_in_cycle(low_voltage:bool);
|
||||
|
||||
|
||||
//keep state during deepsleep
|
||||
fn light(enable:bool);
|
||||
|
||||
fn plant_count() -> i8;
|
||||
fn measure_moisture_b_hz(plant:i8) -> i16;
|
||||
fn measure_moisture_a_hz(plant:i8) -> i16;
|
||||
fn measure_moisture_p_hz(plant:i8) -> i16;
|
||||
fn pump(plant:i8, enable:bool);
|
||||
fn last_pump_time(plant:i8) -> chrono::DateTime<Utc>;
|
||||
fn store_last_pump_time(plant:i8, time: chrono::DateTime<Utc>);
|
||||
fn store_consecutive_pump_count(plant:i8, count:i16);
|
||||
fn consecutive_pump_count(plant:i8) -> i16;
|
||||
|
||||
//keep state during deepsleep
|
||||
fn fault(plant:i8, enable:bool);
|
||||
|
||||
fn default() -> Self;
|
||||
}
|
||||
|
||||
trait Plant{
|
||||
fn setPump(pump:bool);
|
||||
|
||||
|
||||
}
|
||||
|
||||
struct PlantHal<'d>{
|
||||
pump:ShiftRegisterPin<'d>
|
||||
}
|
||||
|
||||
struct PlantCtrlBoard{
|
||||
dummy:i32
|
||||
}
|
||||
|
||||
impl PlantCtrlBoardInteraction for PlantCtrlBoard {
|
||||
fn default() -> Self {
|
||||
let peripherals = Peripherals::take().unwrap();
|
||||
|
||||
let mut adc = AdcDriver::new(peripherals.adc1, &Config::new().calibration(true)).unwrap();
|
||||
let mut adc_pin: esp_idf_hal::adc::AdcChannelDriver<{ attenuation::DB_11 }, _> = AdcChannelDriver::new(peripherals.pins.gpio39).unwrap();
|
||||
let analog_value = adc.read(&mut adc_pin);
|
||||
|
||||
let clock = OldOutputPin::from(PinDriver::output(peripherals.pins.gpio21).unwrap());
|
||||
let latch = OldOutputPin::from(PinDriver::output(peripherals.pins.gpio22).unwrap());
|
||||
let data = OldOutputPin::from(PinDriver::output(peripherals.pins.gpio19).unwrap());
|
||||
|
||||
|
||||
let shift_register = ShiftRegister24::new(clock, latch, data);
|
||||
let registerOutput = shift_register.decompose();
|
||||
|
||||
|
||||
|
||||
Self { dummy: 12 }
|
||||
}
|
||||
|
||||
fn plant_count() -> i8 {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn fault(plant:i8, state:bool) {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn pump(plant:i8, state:bool) {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn battery_state() -> BatteryState {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn is_day() -> bool {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn water_temperature_c() -> u16 {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn tank_sensor_mv() -> u16 {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn light(enable:bool) {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn measure_moisture_b_hz(plant:i8) -> i16 {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn measure_moisture_a_hz(plant:i8) -> i16 {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn measure_moisture_p_hz(plant:i8) -> i16 {
|
||||
todo!()
|
||||
}
|
||||
|
||||
fn last_watering_time(plant:i8) -> chrono::DateTime<Utc> {
|
||||
todo!()
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
fn main() {
|
||||
|
||||
// It is necessary to call this function once. Otherwise some patches to the runtime
|
||||
// implemented by esp-idf-sys might not link properly. See https://github.com/esp-rs/esp-idf-template/issues/71
|
||||
esp_idf_svc::sys::link_patches();
|
||||
|
||||
// Bind the log crate to the ESP Logging facilities
|
||||
esp_idf_svc::log::EspLogger::initialize_default();
|
||||
|
||||
log::info!("Hello, world!");
|
||||
|
||||
|
||||
let board = PlantCtrlBoard::default();
|
||||
|
||||
}
|
Loading…
Reference in New Issue