design
This commit is contained in:
parent
17db1b8a45
commit
825d389a8c
142
rust/src/main.rs
142
rust/src/main.rs
@ -2,6 +2,7 @@ use chrono::Utc;
|
|||||||
use embedded_hal::digital::v1_compat::OldOutputPin;
|
use embedded_hal::digital::v1_compat::OldOutputPin;
|
||||||
use esp_idf_hal::adc::config::Config;
|
use esp_idf_hal::adc::config::Config;
|
||||||
use esp_idf_hal::adc::{AdcDriver, AdcChannelDriver, attenuation};
|
use esp_idf_hal::adc::{AdcDriver, AdcChannelDriver, attenuation};
|
||||||
|
use esp_idf_hal::reset::ResetReason;
|
||||||
use shift_register_driver::sipo::{ShiftRegister24, ShiftRegisterPin};
|
use shift_register_driver::sipo::{ShiftRegister24, ShiftRegisterPin};
|
||||||
use esp_idf_hal::gpio::PinDriver;
|
use esp_idf_hal::gpio::PinDriver;
|
||||||
use esp_idf_hal::prelude::Peripherals;
|
use esp_idf_hal::prelude::Peripherals;
|
||||||
@ -30,32 +31,32 @@ struct BatteryState {
|
|||||||
state_health_percent: u8
|
state_health_percent: u8
|
||||||
}
|
}
|
||||||
trait PlantCtrlBoardInteraction{
|
trait PlantCtrlBoardInteraction{
|
||||||
fn battery_state() -> BatteryState;
|
fn battery_state(&self,) -> BatteryState;
|
||||||
|
|
||||||
fn is_day() -> bool;
|
fn is_day(&self,) -> bool;
|
||||||
fn water_temperature_c() -> u16;
|
fn water_temperature_c(&self,) -> u16;
|
||||||
fn tank_sensor_mv() -> u16;
|
fn tank_sensor_mv(&self,) -> u16;
|
||||||
|
|
||||||
fn set_low_voltage_in_cycle();
|
|
||||||
fn clear_low_voltage_in_cycle();
|
|
||||||
fn low_voltage_in_cycle(low_voltage:bool);
|
|
||||||
|
|
||||||
|
fn set_low_voltage_in_cycle(&self,);
|
||||||
|
fn clear_low_voltage_in_cycle(&self,);
|
||||||
|
fn low_voltage_in_cycle(&self) -> bool;
|
||||||
|
fn any_pump(&self, enabled:bool);
|
||||||
|
|
||||||
//keep state during deepsleep
|
//keep state during deepsleep
|
||||||
fn light(enable:bool);
|
fn light(&self,enable:bool);
|
||||||
|
|
||||||
fn plant_count() -> i8;
|
fn plant_count(&self,) -> i8;
|
||||||
fn measure_moisture_b_hz(plant:i8) -> i16;
|
fn measure_moisture_b_hz(&self,plant:i8) -> i16;
|
||||||
fn measure_moisture_a_hz(plant:i8) -> i16;
|
fn measure_moisture_a_hz(&self,plant:i8) -> i16;
|
||||||
fn measure_moisture_p_hz(plant:i8) -> i16;
|
fn measure_moisture_p_hz(&self,plant:i8) -> i16;
|
||||||
fn pump(plant:i8, enable:bool);
|
fn pump(&self,plant:i8, enable:bool);
|
||||||
fn last_pump_time(plant:i8) -> chrono::DateTime<Utc>;
|
fn last_pump_time(&self,plant:i8) -> chrono::DateTime<Utc>;
|
||||||
fn store_last_pump_time(plant:i8, time: chrono::DateTime<Utc>);
|
fn store_last_pump_time(&self,plant:i8, time: chrono::DateTime<Utc>);
|
||||||
fn store_consecutive_pump_count(plant:i8, count:i16);
|
fn store_consecutive_pump_count(&self,plant:i8, count:i16);
|
||||||
fn consecutive_pump_count(plant:i8) -> i16;
|
fn consecutive_pump_count(&self,plant:i8) -> i16;
|
||||||
|
|
||||||
//keep state during deepsleep
|
//keep state during deepsleep
|
||||||
fn fault(plant:i8, enable:bool);
|
fn fault(&self,plant:i8, enable:bool);
|
||||||
|
|
||||||
fn default() -> Self;
|
fn default() -> Self;
|
||||||
}
|
}
|
||||||
@ -95,53 +96,85 @@ impl PlantCtrlBoardInteraction for PlantCtrlBoard {
|
|||||||
Self { dummy: 12 }
|
Self { dummy: 12 }
|
||||||
}
|
}
|
||||||
|
|
||||||
fn plant_count() -> i8 {
|
fn battery_state(&self,) -> BatteryState {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn fault(plant:i8, state:bool) {
|
fn is_day(&self,) -> bool {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn pump(plant:i8, state:bool) {
|
fn water_temperature_c(&self,) -> u16 {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn battery_state() -> BatteryState {
|
fn tank_sensor_mv(&self,) -> u16 {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn is_day() -> bool {
|
fn set_low_voltage_in_cycle(&self,) {
|
||||||
|
unsafe {
|
||||||
|
LOW_VOLTAGE_DETECTED = true;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
fn clear_low_voltage_in_cycle(&self,) {
|
||||||
|
unsafe {
|
||||||
|
LOW_VOLTAGE_DETECTED = false;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
fn light(&self,enable:bool) {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn water_temperature_c() -> u16 {
|
fn plant_count(&self,) -> i8 {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn tank_sensor_mv() -> u16 {
|
fn measure_moisture_b_hz(&self,plant:i8) -> i16 {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn light(enable:bool) {
|
fn measure_moisture_a_hz(&self,plant:i8) -> i16 {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn measure_moisture_b_hz(plant:i8) -> i16 {
|
fn measure_moisture_p_hz(&self,plant:i8) -> i16 {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn measure_moisture_a_hz(plant:i8) -> i16 {
|
fn pump(&self,plant:i8, enable:bool) {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn measure_moisture_p_hz(plant:i8) -> i16 {
|
fn last_pump_time(&self,plant:i8) -> chrono::DateTime<Utc> {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
fn last_watering_time(plant:i8) -> chrono::DateTime<Utc> {
|
fn store_last_pump_time(&self,plant:i8, time: chrono::DateTime<Utc>) {
|
||||||
todo!()
|
todo!()
|
||||||
}
|
}
|
||||||
|
|
||||||
|
fn store_consecutive_pump_count(&self,plant:i8, count:i16) {
|
||||||
|
todo!()
|
||||||
|
}
|
||||||
|
|
||||||
|
fn consecutive_pump_count(&self,plant:i8) -> i16 {
|
||||||
|
todo!()
|
||||||
|
}
|
||||||
|
|
||||||
|
fn fault(&self,plant:i8, enable:bool) {
|
||||||
|
todo!()
|
||||||
|
}
|
||||||
|
|
||||||
|
fn low_voltage_in_cycle(&self) -> bool {
|
||||||
|
unsafe {
|
||||||
|
return LOW_VOLTAGE_DETECTED;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@ -161,6 +194,53 @@ fn main() {
|
|||||||
log::info!("Hello, world!");
|
log::info!("Hello, world!");
|
||||||
|
|
||||||
|
|
||||||
|
let reasons = ResetReason::get();
|
||||||
|
//init,reset rtc memory depending on cause
|
||||||
|
|
||||||
let board = PlantCtrlBoard::default();
|
let board = PlantCtrlBoard::default();
|
||||||
|
|
||||||
|
//check if we know the time current > 2020
|
||||||
|
//if failed assume its 1.1.1970
|
||||||
|
//12:00 if solar reports day
|
||||||
|
//00:00 if solar repors night
|
||||||
|
|
||||||
|
//check if we have a config file
|
||||||
|
// if not found or parsing error -> error very fast blink general fault
|
||||||
|
//if this happens after a firmeware upgrade (check image state), mark as invalid
|
||||||
|
//blink general fault error_reading_config_after_upgrade, reboot after
|
||||||
|
// open accesspoint with webserver for wlan mqtt setup
|
||||||
|
//blink general fault error_no_config_after_upgrade
|
||||||
|
//once config is set store it and reboot
|
||||||
|
|
||||||
|
//is tank sensor enabled in config?
|
||||||
|
//measure tank level (without wifi due to interference)
|
||||||
|
//if not possible value, blink general fault error_tank_sensor_fault
|
||||||
|
//set general fault persistent
|
||||||
|
//set tank sensor state to fault
|
||||||
|
|
||||||
|
|
||||||
|
//try connect wifi and do mqtt roundtrip
|
||||||
|
// if no wifi, set general fault persistent
|
||||||
|
//if no mqtt, set general fault persistent
|
||||||
|
|
||||||
|
//measure each plant moisture
|
||||||
|
//check which plants need to be watered
|
||||||
|
//()
|
||||||
|
|
||||||
|
//if tank sensor is enabled
|
||||||
|
//if tank sensor fault abort if config require is set
|
||||||
|
//check if water is > minimum allowed || fault
|
||||||
|
//if not, set all plants requiring water to persistent fault
|
||||||
|
// pump water for first plant update last water timestamp
|
||||||
|
// wait for config time per plant
|
||||||
|
//
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
//error codes
|
||||||
|
//error_reading_config_after_upgrade
|
||||||
|
//error_no_config_after_upgrade
|
||||||
|
//error_tank_sensor_fault
|
Loading…
Reference in New Issue