2023-11-23 22:50:17 +01:00
|
|
|
use chrono::{Datelike, Timelike, NaiveDateTime};
|
|
|
|
use build_time::build_time_utc;
|
|
|
|
|
|
|
|
use chrono_tz::Europe::Berlin;
|
|
|
|
use esp_idf_hal::delay::Delay;
|
|
|
|
use plant_hal::{PlantCtrlBoardInteraction, PlantHal, CreatePlantHal, PLANT_COUNT};
|
|
|
|
use anyhow::{Context, Result};
|
|
|
|
use webserver::webserver::httpd;
|
2023-11-21 23:45:15 +01:00
|
|
|
pub mod plant_hal;
|
2023-11-23 22:50:17 +01:00
|
|
|
mod webserver {
|
|
|
|
pub mod webserver;
|
|
|
|
}
|
2023-11-20 01:46:19 +01:00
|
|
|
|
2023-11-23 22:50:17 +01:00
|
|
|
fn web_initial_mode() {
|
|
|
|
//expect running wifi access point!
|
|
|
|
let _httpd = httpd(true);
|
|
|
|
}
|
2023-11-20 01:46:19 +01:00
|
|
|
|
2023-11-23 22:50:17 +01:00
|
|
|
fn main() -> Result<()>{
|
2023-11-20 01:46:19 +01:00
|
|
|
// It is necessary to call this function once. Otherwise some patches to the runtime
|
|
|
|
// implemented by esp-idf-sys might not link properly. See https://github.com/esp-rs/esp-idf-template/issues/71
|
|
|
|
esp_idf_svc::sys::link_patches();
|
|
|
|
|
|
|
|
// Bind the log crate to the ESP Logging facilities
|
|
|
|
esp_idf_svc::log::EspLogger::initialize_default();
|
|
|
|
|
2023-11-23 22:50:17 +01:00
|
|
|
log::info!("Startup Rust");
|
2023-11-20 01:46:19 +01:00
|
|
|
|
2023-11-23 22:50:17 +01:00
|
|
|
let utc_build_time = build_time_utc!();
|
|
|
|
println!("Version was build {}", utc_build_time);
|
2023-11-21 23:45:15 +01:00
|
|
|
|
2023-11-23 22:50:17 +01:00
|
|
|
|
|
|
|
let mut board = PlantHal::create()?;
|
2023-11-21 23:45:15 +01:00
|
|
|
|
2023-11-23 22:50:17 +01:00
|
|
|
|
|
|
|
let time = board.time();
|
|
|
|
let mut cur = match time {
|
|
|
|
Ok(cur) => cur,
|
|
|
|
Err(err) => {
|
|
|
|
log::error!("sntp error {}", err);
|
|
|
|
NaiveDateTime::from_timestamp_millis(0).unwrap().and_utc()
|
|
|
|
}
|
|
|
|
};
|
2023-11-21 23:45:15 +01:00
|
|
|
//check if we know the time current > 2020
|
|
|
|
if cur.year() < 2020 {
|
|
|
|
if board.is_day() {
|
2023-11-23 22:50:17 +01:00
|
|
|
//assume TZ safe times ;)
|
|
|
|
cur = *cur.with_hour(15).get_or_insert(cur);
|
2023-11-21 23:45:15 +01:00
|
|
|
} else {
|
2023-11-23 22:50:17 +01:00
|
|
|
cur = *cur.with_hour(3).get_or_insert(cur);
|
2023-11-21 23:45:15 +01:00
|
|
|
}
|
|
|
|
}
|
2023-11-20 01:46:19 +01:00
|
|
|
|
2023-11-20 02:24:14 +01:00
|
|
|
|
2023-11-21 01:05:12 +01:00
|
|
|
|
|
|
|
//continous/interrupt?
|
|
|
|
//check if boot button is pressed, if longer than 5s delete config and reboot into config mode
|
|
|
|
|
2023-11-21 23:45:15 +01:00
|
|
|
|
2023-11-20 02:24:14 +01:00
|
|
|
//check if we have a config file
|
|
|
|
// if not found or parsing error -> error very fast blink general fault
|
|
|
|
//if this happens after a firmeware upgrade (check image state), mark as invalid
|
|
|
|
//blink general fault error_reading_config_after_upgrade, reboot after
|
|
|
|
// open accesspoint with webserver for wlan mqtt setup
|
|
|
|
//blink general fault error_no_config_after_upgrade
|
|
|
|
//once config is set store it and reboot
|
|
|
|
|
|
|
|
//is tank sensor enabled in config?
|
|
|
|
//measure tank level (without wifi due to interference)
|
2023-11-21 23:45:15 +01:00
|
|
|
//TODO this should be a result// detect invalid measurement value
|
|
|
|
let tank_value = board.tank_sensor_mv();
|
2023-11-23 22:50:17 +01:00
|
|
|
match tank_value {
|
|
|
|
Ok(_) => todo!(),
|
|
|
|
Err(_) => {
|
|
|
|
//if not possible value, blink general fault error_tank_sensor_fault
|
2023-11-21 23:45:15 +01:00
|
|
|
board.general_fault(true);
|
2023-11-20 02:24:14 +01:00
|
|
|
//set general fault persistent
|
|
|
|
//set tank sensor state to fault
|
2023-11-23 22:50:17 +01:00
|
|
|
},
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
|
|
//measure each plant moisture
|
|
|
|
let mut initial_measurements_a: [i32;PLANT_COUNT] = [0;PLANT_COUNT];
|
|
|
|
let mut initial_measurements_b: [i32;PLANT_COUNT] = [0;PLANT_COUNT];
|
|
|
|
let mut initial_measurements_p: [i32;PLANT_COUNT] = [0;PLANT_COUNT];
|
|
|
|
for plant in 0..PLANT_COUNT {
|
|
|
|
initial_measurements_a[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::A)?;
|
|
|
|
initial_measurements_b[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::B)?;
|
|
|
|
initial_measurements_p[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::PUMP)?;
|
|
|
|
}
|
2023-11-21 23:45:15 +01:00
|
|
|
|
2023-11-20 02:24:14 +01:00
|
|
|
|
|
|
|
//try connect wifi and do mqtt roundtrip
|
|
|
|
// if no wifi, set general fault persistent
|
|
|
|
//if no mqtt, set general fault persistent
|
|
|
|
|
2023-11-21 23:45:15 +01:00
|
|
|
|
|
|
|
match board.sntp(1000*120) {
|
|
|
|
Ok(new_time) => cur = new_time,
|
2023-11-23 22:50:17 +01:00
|
|
|
Err(err) => {
|
|
|
|
println!("sntp error: {}", err);
|
|
|
|
}
|
2023-11-21 23:45:15 +01:00
|
|
|
}
|
2023-11-23 22:50:17 +01:00
|
|
|
println!("Running logic at utc {}", cur);
|
|
|
|
let europe_time = cur.with_timezone(&Berlin);
|
|
|
|
println!("Running logic at europe/berlin {}", europe_time);
|
|
|
|
|
2023-11-21 23:45:15 +01:00
|
|
|
|
2023-11-21 01:05:12 +01:00
|
|
|
|
|
|
|
//if config battery mode
|
|
|
|
//read battery level
|
|
|
|
//if not possible set general fault persistent, but do continue
|
|
|
|
//else
|
|
|
|
//assume 12v and max capacity
|
2023-11-20 02:24:14 +01:00
|
|
|
|
|
|
|
//if tank sensor is enabled
|
|
|
|
//if tank sensor fault abort if config require is set
|
|
|
|
//check if water is > minimum allowed || fault
|
|
|
|
//if not, set all plants requiring water to persistent fault
|
2023-11-21 01:05:12 +01:00
|
|
|
|
|
|
|
//for each plant
|
|
|
|
//check if moisture is < target
|
|
|
|
//state += dry
|
|
|
|
//check if in cooldown
|
|
|
|
//state += cooldown
|
|
|
|
//check if consecutive pumps > limit
|
|
|
|
//state += notworking
|
|
|
|
//set plant fault persistent
|
|
|
|
|
|
|
|
//pump one cycle
|
|
|
|
// set last pump time to now
|
|
|
|
//during pump state += active
|
|
|
|
//after pump check if Pump moisture value is increased by config delta x
|
|
|
|
// state -= active
|
|
|
|
// state += cooldown
|
|
|
|
// if not set plant error persistent fault
|
|
|
|
// state += notworking
|
|
|
|
//set consecutive pumps+=1
|
|
|
|
|
|
|
|
|
|
|
|
//check if during light time
|
|
|
|
//lightstate += out of worktime
|
|
|
|
//check battery level
|
|
|
|
//lightstate += battery empty
|
|
|
|
//check solar level if config requires
|
|
|
|
//lightstate += stillday
|
|
|
|
//if no preventing lightstate, enable light
|
|
|
|
//lightstate = active
|
|
|
|
|
2023-11-20 02:24:14 +01:00
|
|
|
|
2023-11-23 22:50:17 +01:00
|
|
|
web_initial_mode();
|
|
|
|
let delay = Delay::new_default();
|
|
|
|
loop {
|
|
|
|
//let freertos do shit
|
|
|
|
delay.delay_ms(1001);
|
|
|
|
}
|
2023-11-20 02:24:14 +01:00
|
|
|
|
2023-11-23 22:50:17 +01:00
|
|
|
return Ok(())
|
2023-11-20 02:24:14 +01:00
|
|
|
|
2023-11-20 01:46:19 +01:00
|
|
|
}
|
2023-11-20 02:24:14 +01:00
|
|
|
|
|
|
|
//error codes
|
|
|
|
//error_reading_config_after_upgrade
|
|
|
|
//error_no_config_after_upgrade
|
|
|
|
//error_tank_sensor_fault
|