use chrono::{Datelike, Timelike, NaiveDateTime};
use build_time::build_time_utc;
use chrono_tz::Europe::Berlin;
use esp_idf_hal::delay::Delay;
use plant_hal::{PlantCtrlBoardInteraction, PlantHal, CreatePlantHal, PLANT_COUNT};
use anyhow::{Context, Result};
use webserver::webserver::httpd;
2023-11-21 23:45:15 +01:00
pub mod plant_hal;
2023-11-23 22:50:17 +01:00
mod webserver {
pub mod webserver;
}
2023-11-20 01:46:19 +01:00
2023-11-23 22:50:17 +01:00
fn web_initial_mode() {
//expect running wifi access point!
let _httpd = httpd(true);
}
2023-11-20 01:46:19 +01:00
2023-11-23 22:50:17 +01:00
fn main() -> Result<()>{
2023-11-20 01:46:19 +01:00
// It is necessary to call this function once. Otherwise some patches to the runtime
// implemented by esp-idf-sys might not link properly. See https://github.com/esp-rs/esp-idf-template/issues/71
esp_idf_svc::sys::link_patches();
// Bind the log crate to the ESP Logging facilities
esp_idf_svc::log::EspLogger::initialize_default();
2023-11-23 22:50:17 +01:00
log::info!("Startup Rust");
2023-11-20 01:46:19 +01:00
2023-11-23 22:50:17 +01:00
let utc_build_time = build_time_utc!();
println!("Version was build {}", utc_build_time);
2023-11-21 23:45:15 +01:00
2023-11-23 22:50:17 +01:00
let mut board = PlantHal::create()?;
2023-11-21 23:45:15 +01:00
2023-11-23 22:50:17 +01:00
let time = board.time();
let mut cur = match time {
Ok(cur) => cur,
Err(err) => {
log::error!("sntp error {}", err);
NaiveDateTime::from_timestamp_millis(0).unwrap().and_utc()
}
};
2023-11-21 23:45:15 +01:00
//check if we know the time current > 2020
if cur.year() < 2020 {
if board.is_day() {
2023-11-23 22:50:17 +01:00
//assume TZ safe times ;)
cur = *cur.with_hour(15).get_or_insert(cur);
2023-11-21 23:45:15 +01:00
} else {
2023-11-23 22:50:17 +01:00
cur = *cur.with_hour(3).get_or_insert(cur);
2023-11-21 23:45:15 +01:00
}
}
2023-11-20 01:46:19 +01:00
2023-11-20 02:24:14 +01:00
2023-11-21 01:05:12 +01:00
//continous/interrupt?
//check if boot button is pressed, if longer than 5s delete config and reboot into config mode
2023-11-21 23:45:15 +01:00
2023-11-20 02:24:14 +01:00
//check if we have a config file
// if not found or parsing error -> error very fast blink general fault
//if this happens after a firmeware upgrade (check image state), mark as invalid
//blink general fault error_reading_config_after_upgrade, reboot after
// open accesspoint with webserver for wlan mqtt setup
//blink general fault error_no_config_after_upgrade
//once config is set store it and reboot
//is tank sensor enabled in config?
//measure tank level (without wifi due to interference)
2023-11-21 23:45:15 +01:00
//TODO this should be a result// detect invalid measurement value
let tank_value = board.tank_sensor_mv();
2023-11-23 22:50:17 +01:00
match tank_value {
Ok(_) => todo!(),
Err(_) => {
//if not possible value, blink general fault error_tank_sensor_fault
2023-11-21 23:45:15 +01:00
board.general_fault(true);
2023-11-20 02:24:14 +01:00
//set general fault persistent
//set tank sensor state to fault
2023-11-23 22:50:17 +01:00
},
}
//measure each plant moisture
let mut initial_measurements_a: [i32;PLANT_COUNT] = [0;PLANT_COUNT];
let mut initial_measurements_b: [i32;PLANT_COUNT] = [0;PLANT_COUNT];
let mut initial_measurements_p: [i32;PLANT_COUNT] = [0;PLANT_COUNT];
for plant in 0..PLANT_COUNT {
initial_measurements_a[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::A)?;
initial_measurements_b[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::B)?;
initial_measurements_p[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::PUMP)?;
}
2023-11-21 23:45:15 +01:00
2023-11-20 02:24:14 +01:00
//try connect wifi and do mqtt roundtrip
// if no wifi, set general fault persistent
//if no mqtt, set general fault persistent
2023-11-21 23:45:15 +01:00
match board.sntp(1000*120) {
Ok(new_time) => cur = new_time,
2023-11-23 22:50:17 +01:00
Err(err) => {
println!("sntp error: {}", err);
}
2023-11-21 23:45:15 +01:00
}
2023-11-23 22:50:17 +01:00
println!("Running logic at utc {}", cur);
let europe_time = cur.with_timezone(&Berlin);
println!("Running logic at europe/berlin {}", europe_time);
2023-11-21 23:45:15 +01:00
2023-11-21 01:05:12 +01:00
//if config battery mode
//read battery level
//if not possible set general fault persistent, but do continue
//else
//assume 12v and max capacity
2023-11-20 02:24:14 +01:00
//if tank sensor is enabled
//if tank sensor fault abort if config require is set
//check if water is > minimum allowed || fault
//if not, set all plants requiring water to persistent fault
2023-11-21 01:05:12 +01:00
//for each plant
//check if moisture is < target
//state += dry
//check if in cooldown
//state += cooldown
//check if consecutive pumps > limit
//state += notworking
//set plant fault persistent
//pump one cycle
// set last pump time to now
//during pump state += active
//after pump check if Pump moisture value is increased by config delta x
// state -= active
// state += cooldown
// if not set plant error persistent fault
// state += notworking
//set consecutive pumps+=1
//check if during light time
//lightstate += out of worktime
//check battery level
//lightstate += battery empty
//check solar level if config requires
//lightstate += stillday
//if no preventing lightstate, enable light
//lightstate = active
2023-11-20 02:24:14 +01:00
2023-11-23 22:50:17 +01:00
web_initial_mode();
let delay = Delay::new_default();
loop {
//let freertos do shit
delay.delay_ms(1001);
}
2023-11-20 02:24:14 +01:00
2023-11-23 22:50:17 +01:00
return Ok(())
2023-11-20 02:24:14 +01:00
2023-11-20 01:46:19 +01:00
}
2023-11-20 02:24:14 +01:00
//error codes
//error_reading_config_after_upgrade
//error_no_config_after_upgrade
//error_tank_sensor_fault