PlantCtrl/esp32/include/HomieConfiguration.h

134 lines
6.5 KiB
C

/** \addtogroup Homie
* @{
*
* @file HomieConfiguration.h
* @author your name (you@domain.com)
* @brief
* @version 0.1
* @date 2020-10-16
*
* @copyright Copyright (c) 2020
* All Settings, configurable in Homie
*
*/
#ifndef HOMIE_PLANT_CONFIG_H
#define HOMIE_PLANT_CONFIG_H
#include "HomieTypes.h"
#define MAX_PLANTS 7
/**
* @name Homie Attributes
* generated Information
* @{
**/
#define NUMBER_TYPE "Float" /**< numberic information, published or read in Homie */
/**
* @name Temperatur Node
* @{
**/
#define TEMPERATURE_NAME "Temperature"
#define TEMPERATURE_UNIT "°C"
#define TEMPERATUR_SENSOR_LIPO "lipo" /**< Homie node: temperatur, setting: lipo temperatur (or close to it) */
#define TEMPERATUR_SENSOR_CHIP "chip" /**< Homie node: temperatur, setting: battery chip */
#define TEMPERATUR_SENSOR_WATER "water" /**< Homie node: temperatur, setting: water temperatur */
/** @}
*
* @name Plant Nodes
* @{
*/
HomieNode plant0("plant0", "Plant 0", "Plant"); /**< dynamic Homie information for first plant */
HomieNode plant1("plant1", "Plant 1", "Plant"); /**< dynamic Homie information for second plant */
HomieNode plant2("plant2", "Plant 2", "Plant"); /**< dynamic Homie information for third plant */
HomieNode plant3("plant3", "Plant 3", "Plant"); /**< dynamic Homie information for fourth plant */
HomieNode plant4("plant4", "Plant 4", "Plant"); /**< dynamic Homie information for fivth plant */
HomieNode plant5("plant5", "Plant 5", "Plant"); /**< dynamic Homie information for sixth plant */
HomieNode plant6("plant6", "Plant 6", "Plant"); /**< dynamic Homie information for seventh plant */
#if defined(TIMED_LIGHT_PIN)
HomieNode timedLightNode("timedLight", "TimedLight", "Status");
#endif // TIMED_LIGHT_PIN
HomieNode sensorLipo("lipo", "Battery Status", "Lipo");
HomieNode sensorSolar("solar", "Solar Status", "Solarpanel");
HomieNode sensorWater("water", "WaterSensor", "Water");
HomieNode sensorTemp("temperature", "Temperature", "temperature");
HomieNode stayAlive("stay", "alive", "alive"); /**< Necessary for Mqtt Active Command */
/**
* @}
*/
/**
* @name Settings
* General settings for the controller
* @{
*/
HomieSetting<long> deepSleepTime("sleep", "time in seconds to sleep");
HomieSetting<long> deepSleepNightTime("nightsleep", "time in seconds to sleep (0 uses same setting: deepsleep at night, too)");
HomieSetting<long> pumpIneffectiveWarning("pumpConsecutiveWarn", "if the pump was triggered this amount directly after each cooldown, without resolving dryness, warn");
HomieSetting<long> waterLevelMax("tankmax", "distance (mm) at maximum water level");
HomieSetting<long> waterLevelMin("tankmin", "distance (mm) at minimum water level (pumps still covered)");
HomieSetting<long> waterLevelWarn("tankwarn", "warn (mm) if below this water level %");
HomieSetting<long> waterLevelVol("tankVolume", "(ml) between minimum and maximum");
HomieSetting<const char *> lipoSensorAddr("lipoDSAddr", "1wire address for lipo temperature sensor");
HomieSetting<const char *> waterSensorAddr("tankDSAddr", "1wire address for water temperature sensor");
HomieSetting<const char *> ntpServer("ntpServer", "NTP server (pool.ntp.org as default)");
#if defined(TIMED_LIGHT_PIN)
HomieSetting<double> timedLightVoltageCutoff("LightVoltageCutoff", "voltage at wich to disable light");
HomieSetting<long> timedLightStart("LightStart", "hour to start light");
HomieSetting<long> timedLightEnd("LightEnd", "hour to end light");
HomieSetting<bool> timedLightOnlyWhenDark("LightOnlyDark", "only enable light, if solar is low");
#endif // TIMED_LIGHT_PIN
/**
* @}
*/
/**
* @name Plant specific ones
* Setting for one plant
* @{
**/
#define GENERATE_PLANT(plant, strplant) \
HomieSetting<double> mSensorDry##plant = HomieSetting<double>("dry" strplant, "Plant " strplant "- Moist sensor dry %"); \
HomieSetting<long> pSensorType##plant = HomieSetting<long>("sensoryType" strplant, "sensor" strplant " - sensortype"); \
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("hourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("hourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("lowLight" strplant, "Plant" strplant " - Enable the Pump only, when there is no sunlight"); \
HomieSetting<long> mPumpCooldownInMinutes##plant = HomieSetting<long>("delay" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
HomieSetting<long> pPumpDuration##plant = HomieSetting<long>("pumpDuration" strplant, "Plant" strplant " - time seconds to water when pump is active"); \
HomieSetting<long> pPumpMl##plant = HomieSetting<long>("pumpAmount" strplant, "Plant" strplant " - ml (if using flowmeter) to water when pump is active"); \
HomieSetting<long> pPowerLevel##plant = HomieSetting<long>("powerLevel" strplant, "Plant" strplant " - pwm duty cycle in percent"); \
PlantSettings_t mSetting##plant = {&mSensorDry##plant, &pSensorType##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInMinutes##plant, &pPumpDuration##plant, &pPowerLevel##plant, &pPumpMl##plant}; \
/**< Generate all settings for one plant \
* \
* Feature to start pumping only at morning: @link{SOLAR_CHARGE_MIN_VOLTAGE} and @link{SOLAR_CHARGE_MAX_VOLTAGE} \
*/
/**
* @}
*/
GENERATE_PLANT(0, "0"); /**< Homie settings for first plant */
GENERATE_PLANT(1, "1"); /**< Homie settings for second Plant */
GENERATE_PLANT(2, "2"); /**< Homie settings for third plant */
GENERATE_PLANT(3, "3"); /**< Homie settings for fourth plant */
GENERATE_PLANT(4, "4"); /**< Homie settings for fifth plant */
GENERATE_PLANT(5, "5"); /**< Homie settings for sixth plant */
GENERATE_PLANT(6, "6"); /**< Homie settings for seventh plant */
#endif /* HOMIE_PLANT_CONFIG_H @} */