3 Commits

Author SHA1 Message Date
55ab8bcccf refctor: TankInfo structure (consistent layout)
- fix: use tagged enum serialization for TankError
- fix: rename TankInfo fields for consistent naming (volume_ml, pct, water_temp_c)
2026-05-10 12:49:52 +02:00
8700512aa4 refactor: PlantInfo structure (consistent layout)
- fix: use tagged enum serialization for MoistureSensorError and PumpError
- fix: flatten PlantInfo sensors to SensorTelemetry with top-level moisture_pct
2026-05-10 12:49:16 +02:00
849a2b78ae refactor: BatteryInfo structure (consistent layout)
- use tagged enum serialization for BatteryError
- flatten BatteryInfo telemetry with consistent field names and typed error
2026-05-10 12:47:58 +02:00
4 changed files with 116 additions and 56 deletions

View File

@@ -27,20 +27,22 @@ pub trait BatteryInteraction {
#[derive(Debug, Serialize)]
pub struct BatteryInfo {
pub voltage_milli_volt: u16,
pub average_current_milli_ampere: i16,
pub cycle_count: u16,
pub design_milli_ampere_hour: u16,
pub remaining_milli_ampere_hour: u16,
pub state_of_charge: f32,
pub state_of_health: u16,
pub temperature: u16,
pub voltage_mv: Option<u16>,
pub current_ma: Option<i16>,
pub soc_pct: Option<f32>,
pub soh_pct: Option<u16>,
pub temperature_c: Option<u16>,
pub cycle_count: Option<u16>,
pub remaining_mah: Option<u16>,
pub design_mah: Option<u16>,
pub error: Option<BatteryError>,
}
#[derive(Debug, Serialize)]
#[serde(tag = "kind")]
pub enum BatteryError {
NoBatteryMonitor,
CommunicationError(String),
CommunicationError { message: String },
}
#[derive(Debug, Serialize)]
@@ -180,14 +182,15 @@ impl BatteryInteraction for BQ34Z100G1 {
async fn get_battery_state(&mut self) -> FatResult<BatteryState> {
Ok(BatteryState::Info(BatteryInfo {
voltage_milli_volt: self.voltage_milli_volt().await?,
average_current_milli_ampere: self.average_current_milli_ampere().await?,
cycle_count: self.cycle_count().await?,
design_milli_ampere_hour: self.design_milli_ampere_hour().await?,
remaining_milli_ampere_hour: self.remaining_milli_ampere_hour().await?,
state_of_charge: self.state_charge_percent().await?,
state_of_health: self.state_health_percent().await?,
temperature: self.bat_temperature().await?,
voltage_mv: Some(self.voltage_milli_volt().await?),
current_ma: Some(self.average_current_milli_ampere().await?),
soc_pct: Some(self.state_charge_percent().await?),
soh_pct: Some(self.state_health_percent().await?),
temperature_c: Some(self.bat_temperature().await?),
cycle_count: Some(self.cycle_count().await?),
remaining_mah: Some(self.remaining_milli_ampere_hour().await?),
design_mah: Some(self.design_milli_ampere_hour().await?),
error: None,
}))
}
}

View File

@@ -43,7 +43,7 @@ use embassy_time::{Duration, Instant, Timer};
use esp_hal::rom::ets_delay_us;
use esp_hal::system::software_reset;
use esp_println::{logger, println};
use hal::battery::BatteryState;
use hal::battery::{BatteryError, BatteryInfo, BatteryState};
use log::LogMessage;
use option_lock::OptionLock;
use plant_state::PlantState;
@@ -307,7 +307,7 @@ async fn safe_main(spawner: Spawner) -> FatResult<()> {
if let Some(err) = tank_state.got_error(&board.board_hal.get_config().tank) {
match err {
TankError::SensorDisabled => { /* unreachable */ }
TankError::SensorMissing(raw_value_mv) => log(
TankError::SensorMissing { raw_mv: raw_value_mv } => log(
LogMessage::TankSensorMissing,
raw_value_mv as u32,
0,
@@ -321,8 +321,8 @@ async fn safe_main(spawner: Spawner) -> FatResult<()> {
&format!("{value}"),
"",
),
TankError::BoardError(err) => {
log(LogMessage::TankSensorBoardError, 0, 0, "", &err.to_string())
TankError::BoardError { message: err } => {
log(LogMessage::TankSensorBoardError, 0, 0, "", &err)
}
}
// disabled cannot trigger this because of wrapping if is_enabled
@@ -857,20 +857,40 @@ async fn publish_mppt_state(
async fn publish_battery_state(
board: &mut MutexGuard<'_, CriticalSectionRawMutex, HAL<'static>>,
) -> () {
let state = board
let telemetry = match board
.board_hal
.get_battery_monitor()
.get_battery_state()
.await;
let value = match state {
Ok(state) => {
let json = serde_json::to_string(&state).unwrap().to_owned();
json.to_owned()
}
Err(_) => "error".to_owned(),
};
.await
{
let _ = mqtt::publish("/battery", &*value).await;
Ok(BatteryState::Info(info)) => info,
Ok(BatteryState::Unknown) => BatteryInfo {
voltage_mv: None,
current_ma: None,
soc_pct: None,
soh_pct: None,
temperature_c: None,
cycle_count: None,
remaining_mah: None,
design_mah: None,
error: Some(BatteryError::NoBatteryMonitor),
},
Err(e) => BatteryInfo {
voltage_mv: None,
current_ma: None,
soc_pct: None,
soh_pct: None,
temperature_c: None,
cycle_count: None,
remaining_mah: None,
design_mah: None,
error: Some(BatteryError::CommunicationError {
message: alloc::format!("{:?}", e),
}),
},
};
if let Ok(json) = serde_json::to_string(&telemetry) {
let _ = mqtt::publish("/battery", &json).await;
}
}

View File

@@ -11,11 +11,12 @@ use serde::{Deserialize, Serialize};
const MOIST_SENSOR_MAX_FREQUENCY: f32 = 7500.; // 60kHz (500Hz margin)
const MOIST_SENSOR_MIN_FREQUENCY: f32 = 150.; // this is really, really dry, think like cactus levels
#[derive(Debug, PartialEq, Serialize)]
#[derive(Debug, PartialEq, Clone, Serialize)]
#[serde(tag = "kind")]
pub enum MoistureSensorError {
ShortCircuit { hz: f32, max: f32 },
OpenLoop { hz: f32, min: f32 },
BoardError(String),
BoardError { message: String },
}
#[derive(Debug, PartialEq, Serialize)]
@@ -49,6 +50,14 @@ impl MoistureSensorState {
impl MoistureSensorState {}
#[derive(Debug, PartialEq, Serialize)]
pub struct SensorTelemetry {
pub moisture_pct: Option<f32>,
pub raw_hz: Option<f32>,
pub error: Option<MoistureSensorError>,
}
#[derive(Debug, PartialEq, Serialize)]
#[serde(tag = "kind")]
pub enum PumpError {
PumpNotWorking {
failed_attempts: usize,
@@ -134,9 +143,9 @@ impl PlantState {
},
Err(err) => MoistureSensorState::SensorError(err),
},
Err(err) => MoistureSensorState::SensorError(MoistureSensorError::BoardError(
err.to_string(),
)),
Err(err) => MoistureSensorState::SensorError(MoistureSensorError::BoardError {
message: err.to_string(),
})
}
} else {
MoistureSensorState::Disabled
@@ -159,9 +168,9 @@ impl PlantState {
},
Err(err) => MoistureSensorState::SensorError(err),
},
Err(err) => MoistureSensorState::SensorError(MoistureSensorError::BoardError(
err.to_string(),
)),
Err(err) => MoistureSensorState::SensorError(MoistureSensorError::BoardError {
message: err.to_string(),
})
}
} else {
MoistureSensorState::Disabled
@@ -277,13 +286,15 @@ impl PlantState {
&self,
plant_conf: &PlantConfig,
current_time: &DateTime<Tz>,
) -> PlantInfo<'_> {
) -> PlantInfo {
let (moisture_pct, _) = self.plant_moisture();
PlantInfo {
sensor_a: &self.sensor_a,
sensor_b: &self.sensor_b,
moisture_pct,
sensor_a: Self::sensor_to_telemetry(&self.sensor_a),
sensor_b: Self::sensor_to_telemetry(&self.sensor_b),
mode: plant_conf.mode,
do_water: self.needs_to_be_watered(plant_conf, current_time),
dry: if let Some(moisture_percent) = self.plant_moisture().0 {
dry: if let Some(moisture_percent) = moisture_pct {
moisture_percent < plant_conf.target_moisture
} else {
false
@@ -316,15 +327,40 @@ impl PlantState {
},
}
}
fn sensor_to_telemetry(sensor: &MoistureSensorState) -> SensorTelemetry {
match sensor {
MoistureSensorState::Disabled => SensorTelemetry {
moisture_pct: None,
raw_hz: None,
error: None,
},
MoistureSensorState::MoistureValue {
raw_hz,
moisture_percent,
} => SensorTelemetry {
moisture_pct: Some(*moisture_percent),
raw_hz: Some(*raw_hz),
error: None,
},
MoistureSensorState::SensorError(err) => SensorTelemetry {
moisture_pct: None,
raw_hz: None,
error: Some(err.clone()),
},
}
}
}
#[derive(Debug, PartialEq, Serialize)]
/// State of a single plant to be tracked
pub struct PlantInfo<'a> {
pub struct PlantInfo {
/// combined plant moisture from available sensors
moisture_pct: Option<f32>,
/// state of humidity sensor on bank a
sensor_a: &'a MoistureSensorState,
sensor_a: SensorTelemetry,
/// state of humidity sensor on bank b
sensor_b: &'a MoistureSensorState,
sensor_b: SensorTelemetry,
/// configured plant watering mode
mode: PlantWateringMode,
/// the plant needs to be watered

View File

@@ -10,11 +10,12 @@ const OPEN_TANK_VOLTAGE: f32 = 3.0;
pub const WATER_FROZEN_THRESH: f32 = 4.0;
#[derive(Debug, Clone, Serialize)]
#[serde(tag = "kind")]
pub enum TankError {
SensorDisabled,
SensorMissing(f32),
SensorMissing { raw_mv: f32 },
SensorValueError { value: f32, min: f32, max: f32 },
BoardError(String),
BoardError { message: String },
}
pub enum TankState {
@@ -25,7 +26,7 @@ pub enum TankState {
fn raw_voltage_to_divider_percent(raw_value_mv: f32) -> Result<f32, TankError> {
if raw_value_mv > OPEN_TANK_VOLTAGE {
return Err(TankError::SensorMissing(raw_value_mv));
return Err(TankError::SensorMissing { raw_mv: raw_value_mv });
}
let r2 = raw_value_mv * 50.0 / (3.3 - raw_value_mv);
@@ -141,15 +142,15 @@ impl TankState {
TankInfo {
enough_water,
warn_level,
left_ml,
volume_ml: left_ml,
sensor_error: tank_err,
raw,
water_frozen: water_temp
.as_ref()
.is_ok_and(|temp| *temp < WATER_FROZEN_THRESH),
water_temp: water_temp.as_ref().copied().ok(),
water_temp_c: water_temp.as_ref().copied().ok(),
temp_sensor_error: water_temp.as_ref().err().map(|err| err.to_string()),
percent,
pct: percent,
}
}
}
@@ -164,7 +165,7 @@ pub async fn determine_tank_state(
.and_then(|f| core::prelude::v1::Ok(f.tank_sensor_voltage()))
{
Ok(raw_sensor_value_mv) => TankState::Present(raw_sensor_value_mv.await.unwrap()),
Err(err) => TankState::Error(TankError::BoardError(err.to_string())),
Err(err) => TankState::Error(TankError::BoardError { message: err.to_string() }),
}
} else {
TankState::Disabled
@@ -179,16 +180,16 @@ pub struct TankInfo {
/// warning that water needs to be refilled soon
pub(crate) warn_level: bool,
/// estimation how many ml are still in the tank
pub(crate) left_ml: Option<f32>,
pub(crate) volume_ml: Option<f32>,
/// if there is an issue with the water level sensor
pub(crate) sensor_error: Option<TankError>,
/// raw water sensor value
pub(crate) raw: Option<f32>,
/// percent value
pub(crate) percent: Option<f32>,
pub(crate) pct: Option<f32>,
/// water in the tank might be frozen
pub(crate) water_frozen: bool,
/// water temperature
pub(crate) water_temp: Option<f32>,
pub(crate) water_temp_c: Option<f32>,
pub(crate) temp_sensor_error: Option<String>,
}