Commit Graph

220 Commits

Author SHA1 Message Date
Ollo
aa7cb31302 Activate Sensors and Pumps if Lipo is charged 2024-05-11 15:22:49 +02:00
Ollo
cbde8ee11c Battery voltage below minimum should be treated as 0% 2024-04-20 13:39:16 +02:00
Ollo
d2f1605b90 Sleep 2 hours on low battery 2024-04-07 12:50:12 +02:00
Ollo
48e5383106 Print Moisture measurement debugging in MQTT 2024-04-01 13:02:26 +02:00
Ollo
ff081a8d44 Increase deepsleep time 2024-04-01 12:10:22 +02:00
Ollo
3764183944 uniq message for ESP OTA state 2024-04-01 11:48:29 +02:00
Ollo
c85f69c545 Fixed low light information, by comparing it with minimum value 2024-03-28 20:39:43 +01:00
Ollo
97a88ebb91 Merge master 2024-03-08 20:39:49 +01:00
Ollo
f8629586f8 Calculate water percentage below 30 percent 2024-02-24 16:21:39 +01:00
Ollo
4f7e57988b analog water measurement added 2024-02-18 15:07:06 +01:00
Empire
fbbbc5f5aa fix ota 2023-08-02 21:45:36 +02:00
Empire
6d5f68fab5 Merge branch 'master' of github.com:0110/PlantCtrl 2023-07-20 20:11:58 +02:00
Ollo
9167da5a82 Refactoring 2023-06-20 18:06:29 +02:00
Ollo
f65132652c Optional features can be controlled via platformio.ini and are mentioned in firmware name on MQTT 2023-06-20 17:53:19 +02:00
Empire
703553beb4 Merge branch 'master' of github.com:0110/PlantCtrl 2023-06-15 21:44:00 +02:00
Ollo
2636e2defa Read more distances 2023-06-11 13:51:13 +02:00
Ollo
c6ddfea44b Handle unrealistic water values 2023-06-11 13:28:52 +02:00
Empire
85bcbd166c Fix remaining mqtt calculation 2023-06-04 19:21:53 +02:00
Ollo
6cb446735d Adapted default work time, as internal time is UTC 2023-05-28 10:53:43 +02:00
Ollo
ab17709435 More serial debuging (parsing 1WIRE Addresses failed) 2023-05-27 09:12:55 +02:00
Empire
cf7ff9b0d1 added ota state debugging 2023-05-17 18:24:27 +02:00
Your Name
1cc46a360b fixed not watering when water is left 2023-04-26 08:33:12 +02:00
Ollo
2a2a36b267 sleep at least several minutes, so the solar panel can charge the battery 2023-04-06 17:56:17 +02:00
Ollo
9f2e21d94c Sleep 3 times longer, if the battery voltage is low 2023-03-25 14:21:33 +01:00
Ollo
5df69f20a8 Stop pumps due to water sensor 2023-03-24 18:40:57 +01:00
Ollo
704684d437 Fixed water distance and publish percentage 2023-03-24 18:06:21 +01:00
Ollo
ab480041b2 Removed timeout 2023-03-10 23:37:50 +01:00
Ollo
1fad63a84d Start I2C sensor after power was activated 2023-03-10 22:50:16 +01:00
Ollo
712ef73a30 Merged master into ollo-dev 2023-03-10 20:06:05 +01:00
Empire
63ed9afabc stuff changed 2023-03-03 19:58:55 +01:00
Empire
3835bd96a1 Revert "Revert "add resistive frequency sensor, updated dependencies""
This reverts commit 42ce4cdda2.
2023-02-12 12:51:52 +01:00
Empire
42ce4cdda2 Revert "add resistive frequency sensor, updated dependencies"
This reverts commit 17d16a6eef.
2023-02-12 12:40:38 +01:00
Empire
2b6d766492 fix water error code 2023-02-10 22:23:04 +01:00
Empire
68386ce02f Merge branch 'master' of github.com:0110/PlantCtrl 2023-02-10 22:12:57 +01:00
Empire
17d16a6eef add resistive frequency sensor, updated dependencies 2023-02-10 22:08:29 +01:00
Your Name
43e638a587 set more state retained 2022-12-20 00:07:25 +01:00
37a08dede6 add frozen water mode 2022-12-20 00:04:57 +01:00
Ollo
195d3d3c1b Ignore voltages above 100V 2022-08-25 18:40:41 +02:00
Ollo
18b927bd59 Publish state as number and string 2022-08-21 12:05:43 +02:00
Ollo
c444117853 code refactoring: use the defined states of header file 2022-08-21 11:59:50 +02:00
662d7bc853 add timer only mode, more sane default config 2022-05-20 01:00:04 +02:00
5dedc76727 formating only 2022-04-29 10:47:54 +02:00
15e96a4990 ensure compilation with bricking limits is not possible 2022-04-29 10:47:46 +02:00
0dd4553999 do not use pump for download indication anymore 2022-04-29 10:47:16 +02:00
7a841d423b use more sane default (pump always not only at night) 2022-04-29 10:45:59 +02:00
Empire
c43da98245 Merge branch 'hydro'
# Conflicts:
#	esp32/PlantControl.code-workspace
#	esp32/include/ControllerConfiguration.h
#	esp32/platformio.ini
#	esp32/src/main.cpp
2022-04-27 19:19:26 +00:00
Ollo
6c475a2ade Sensor types are defined in platformio.ini 2022-03-06 14:25:14 +01:00
Empire
defbcca8ae sht20 support 2022-03-05 09:31:43 +00:00
c3ma
1161c62a90 print into mqtt the sensor mode 2022-02-19 02:51:36 +01:00
c3ma
a0f8df7016 fix for capacitive sensors not working, enum introduction for sensormode 2022-02-19 02:24:19 +01:00