Commit Graph

158 Commits

Author SHA1 Message Date
Ollo
2fad7ebbaf Change solar factor to dd3888ba52 2024-06-25 20:53:15 +02:00
Ollo
7d6c1c3daa Disable all outputs (power safing), float number cannot be compared 2024-05-19 21:36:10 +02:00
Ollo
aa7cb31302 Activate Sensors and Pumps if Lipo is charged 2024-05-11 15:22:49 +02:00
Ollo
cbde8ee11c Battery voltage below minimum should be treated as 0% 2024-04-20 13:39:16 +02:00
Ollo
dd3888ba52 Change Solar factor for Revision 0.10 2024-04-20 12:51:33 +02:00
Ollo
d2f1605b90 Sleep 2 hours on low battery 2024-04-07 12:50:12 +02:00
Ollo
cb37426fbb Deepsleep increased and Sensor-Enable for HW0.7 corrected 2024-04-01 13:03:04 +02:00
Ollo
3764183944 uniq message for ESP OTA state 2024-04-01 11:48:29 +02:00
Ollo
7494f9de51 Different factor to read solar voltage between HW0.7 and HW0.10 2024-03-28 20:37:19 +01:00
Ollo
9c4e747b50 Added Compatibilitymode for hardware revision 0.7 2024-03-10 16:53:54 +01:00
Ollo
97a88ebb91 Merge master 2024-03-08 20:39:49 +01:00
Ollo
4f7e57988b analog water measurement added 2024-02-18 15:07:06 +01:00
Empire
fbbbc5f5aa fix ota 2023-08-02 21:45:36 +02:00
Ollo
f65132652c Optional features can be controlled via platformio.ini and are mentioned in firmware name on MQTT 2023-06-20 17:53:19 +02:00
Ollo
2636e2defa Read more distances 2023-06-11 13:51:13 +02:00
Ollo
c6ddfea44b Handle unrealistic water values 2023-06-11 13:28:52 +02:00
Empire
cf7ff9b0d1 added ota state debugging 2023-05-17 18:24:27 +02:00
Ollo
2a2a36b267 sleep at least several minutes, so the solar panel can charge the battery 2023-04-06 17:56:17 +02:00
Ollo
9f2e21d94c Sleep 3 times longer, if the battery voltage is low 2023-03-25 14:21:33 +01:00
Empire
a84344f978 Merge branch 'ollo-dev' 2023-03-24 19:55:14 +01:00
Ollo
90f2d821a7 Swapped water sensor pins 2023-03-22 22:04:49 +01:00
Empire
e8759435e7 frequency resistive sensor adjustment 2023-03-22 21:43:52 +01:00
Ollo
ab480041b2 Removed timeout 2023-03-10 23:37:50 +01:00
Ollo
1fad63a84d Start I2C sensor after power was activated 2023-03-10 22:50:16 +01:00
Ollo
712ef73a30 Merged master into ollo-dev 2023-03-10 20:06:05 +01:00
Empire
3835bd96a1 Revert "Revert "add resistive frequency sensor, updated dependencies""
This reverts commit 42ce4cdda2.
2023-02-12 12:51:52 +01:00
Empire
42ce4cdda2 Revert "add resistive frequency sensor, updated dependencies"
This reverts commit 17d16a6eef.
2023-02-12 12:40:38 +01:00
Empire
2b6d766492 fix water error code 2023-02-10 22:23:04 +01:00
Empire
68386ce02f Merge branch 'master' of github.com:0110/PlantCtrl 2023-02-10 22:12:57 +01:00
Empire
17d16a6eef add resistive frequency sensor, updated dependencies 2023-02-10 22:08:29 +01:00
Your Name
2914a0c7a1 slightly adjust range for better precision 2022-12-20 00:07:25 +01:00
37a08dede6 add frozen water mode 2022-12-20 00:04:57 +01:00
Ollo
195d3d3c1b Ignore voltages above 100V 2022-08-25 18:40:41 +02:00
Ollo
e820301490 Tweak state numbers 2022-08-23 20:26:11 +02:00
Ollo
29e3aa08cb Fixed unit description for cooldown 2022-08-22 18:08:19 +02:00
Ollo
791d6f04b0 Tweaked number 2022-08-21 12:12:07 +02:00
Ollo
79ffd8acff Version increased 2022-08-21 12:07:43 +02:00
Ollo
c444117853 code refactoring: use the defined states of header file 2022-08-21 11:59:50 +02:00
Ollo
5d24a51bd9 Plant states defined in header 2022-08-21 11:52:15 +02:00
Ollo
71b9150279 Restore frequency boundaries (7a54065a5f) 2022-06-25 17:43:23 +02:00
662d7bc853 add timer only mode, more sane default config 2022-05-20 01:00:04 +02:00
4a86d8c41c fixed analog probe being backwards, extended range for frequency one 2022-04-29 10:14:50 +02:00
Empire
c43da98245 Merge branch 'hydro'
# Conflicts:
#	esp32/PlantControl.code-workspace
#	esp32/include/ControllerConfiguration.h
#	esp32/platformio.ini
#	esp32/src/main.cpp
2022-04-27 19:19:26 +00:00
Ollo
6c475a2ade Sensor types are defined in platformio.ini 2022-03-06 14:25:14 +01:00
Ollo
9a172c269e Swapped max and min for analog mapping 2022-03-06 14:05:54 +01:00
Ollo
868d3d912e Update the analog maximum according datasheet 2022-03-06 13:47:21 +01:00
Empire
defbcca8ae sht20 support 2022-03-05 09:31:43 +00:00
c3ma
a0f8df7016 fix for capacitive sensors not working, enum introduction for sensormode 2022-02-19 02:24:19 +01:00
c3ma
d0320beaa7 allow sensor type selection per plant, changed calculations to use PCT values, due to different raw value meaning 2022-02-12 05:26:54 +01:00
Ollo
7a54065a5f Reduced frequrency boundery 2022-01-25 22:11:38 +01:00