allow sensor type selection per plant, changed calculations to use PCT values, due to different raw value meaning
This commit is contained in:
+52
-31
@@ -209,7 +209,7 @@ void readOneWireSensors()
|
||||
continue;
|
||||
}
|
||||
|
||||
char buf[(sizeof(ds18b20Address) * 2)+1]; /* additional byte for trailing terminator */
|
||||
char buf[(sizeof(ds18b20Address) * 2) + 1]; /* additional byte for trailing terminator */
|
||||
snprintf(buf, sizeof(buf), "%.2X%.2X%.2X%.2X%.2X%.2X%.2X%.2X",
|
||||
ds18b20Address[0],
|
||||
ds18b20Address[1],
|
||||
@@ -269,7 +269,27 @@ void readPowerSwitchedSensors()
|
||||
|
||||
for (int i = 0; i < MAX_PLANTS; i++)
|
||||
{
|
||||
Serial << "Plant " << i << " measurement: " << mPlants[i].getCurrentMoisture() << " hz" << endl;
|
||||
mPlants[i].blockingMoistureMeasurement();
|
||||
}
|
||||
|
||||
for (int i = 0; i < MAX_PLANTS; i++)
|
||||
{
|
||||
if (mPlants[i].isSensorMode(SENSOR_CAPACITIVE_FREQUENCY_MOD))
|
||||
{
|
||||
Serial << "Plant " << i << " measurement: " << mPlants[i].getCurrentMoistureRaw() << " hz" << endl;
|
||||
}
|
||||
else if (mPlants[i].isSensorMode(SENSOR_ANALOG_RESISTANCE_PROBE))
|
||||
{
|
||||
Serial << "Plant " << i << " measurement: " << mPlants[i].getCurrentMoistureRaw() << " mV" << endl;
|
||||
}
|
||||
else if (mPlants[i].isSensorMode(SENSOR_NONE))
|
||||
{
|
||||
Serial << "Plant " << i << " measurement: no sensor configured" << endl;
|
||||
}
|
||||
else
|
||||
{
|
||||
log(LOG_LEVEL_ERROR, LOG_SENSORMODE_UNKNOWN, LOG_SENSORMODE_UNKNOWN_CODE);
|
||||
}
|
||||
}
|
||||
|
||||
waterRawSensor.clear();
|
||||
@@ -408,7 +428,7 @@ int determineNextPump(bool isLowLight)
|
||||
}
|
||||
if (!plant.isHydroponic())
|
||||
{
|
||||
if (equalish(plant.getCurrentMoisture(), MISSING_SENSOR))
|
||||
if (equalish(plant.getCurrentMoistureRaw(), MISSING_SENSOR))
|
||||
{
|
||||
plant.publishState("nosensor");
|
||||
log(LOG_LEVEL_ERROR, String(String(i) + " No pump possible: missing sensor"), LOG_MISSING_PUMP);
|
||||
@@ -631,7 +651,7 @@ void pumpActiveLoop()
|
||||
#endif
|
||||
|
||||
long pumpStarted = pumpTarget - (mPlants[pumpToRun].getPumpDuration() * 1000);
|
||||
long duration = millis()-pumpStarted;
|
||||
long duration = millis() - pumpStarted;
|
||||
if (millis() > pumpTarget)
|
||||
{
|
||||
mPlants[pumpToRun].setProperty("watertime").send(String(duration));
|
||||
@@ -704,33 +724,7 @@ void safeSetup()
|
||||
return;
|
||||
}
|
||||
|
||||
/************************* Start One-Wire bus ***************/
|
||||
int tempInitStartTime = millis();
|
||||
uint8_t sensorCount = 0U;
|
||||
|
||||
/* Required to read the temperature at least once */
|
||||
while ((sensorCount == 0 || !battery.isFound()) && millis() < tempInitStartTime + TEMPERATUR_TIMEOUT)
|
||||
{
|
||||
sensors.begin();
|
||||
battery.begin();
|
||||
sensorCount = sensors.getDS18Count();
|
||||
delay(50);
|
||||
}
|
||||
|
||||
Serial << "DS18S20 count: " << sensorCount << " found in " << (millis() - tempInitStartTime) << " ms" << endl;
|
||||
Serial.flush();
|
||||
/* Measure temperature TODO idea: move this into setup */
|
||||
if (sensorCount > 0)
|
||||
{
|
||||
//sensors.setResolution(DS18B20_RESOLUTION);
|
||||
sensors.requestTemperatures();
|
||||
}
|
||||
Serial << "Reading sensors start" << endl;
|
||||
Serial.flush();
|
||||
readPowerSwitchedSensors();
|
||||
Serial << "Reading sensors end" << endl;
|
||||
Serial.flush();
|
||||
/************************* Start Homie Framework ***************/
|
||||
/************************* Start Homie Framework ***************/
|
||||
Homie_setFirmware("PlantControl", FIRMWARE_VERSION);
|
||||
Homie.disableLedFeedback();
|
||||
Homie_setBrand("PlantControl");
|
||||
@@ -766,9 +760,36 @@ void safeSetup()
|
||||
|
||||
Homie.setup();
|
||||
|
||||
/************************* Start One-Wire bus ***************/
|
||||
int tempInitStartTime = millis();
|
||||
uint8_t sensorCount = 0U;
|
||||
|
||||
/* Required to read the temperature at least once */
|
||||
while ((sensorCount == 0 || !battery.isFound()) && millis() < tempInitStartTime + TEMPERATUR_TIMEOUT)
|
||||
{
|
||||
sensors.begin();
|
||||
battery.begin();
|
||||
sensorCount = sensors.getDS18Count();
|
||||
delay(50);
|
||||
}
|
||||
|
||||
Serial << "DS18S20 count: " << sensorCount << " found in " << (millis() - tempInitStartTime) << " ms" << endl;
|
||||
Serial.flush();
|
||||
/* Measure temperature TODO idea: move this into setup */
|
||||
if (sensorCount > 0)
|
||||
{
|
||||
//sensors.setResolution(DS18B20_RESOLUTION);
|
||||
sensors.requestTemperatures();
|
||||
}
|
||||
|
||||
mConfigured = Homie.isConfigured();
|
||||
if (mConfigured)
|
||||
{
|
||||
Serial << "Reading sensors start" << endl;
|
||||
Serial.flush();
|
||||
readPowerSwitchedSensors();
|
||||
Serial << "Reading sensors end" << endl;
|
||||
Serial.flush();
|
||||
for (int i = 0; i < MAX_PLANTS; i++)
|
||||
{
|
||||
mPlants[i].advertise();
|
||||
|
||||
Reference in New Issue