@@ -12,8 +12,7 @@
|
||||
#ifndef PLANT_CTRL_H
|
||||
#define PLANT_CTRL_H
|
||||
|
||||
#include <HomieSetting.hpp>
|
||||
#include <SendingPromise.hpp>
|
||||
#include "HomieTypes.h"
|
||||
|
||||
class Plant {
|
||||
|
||||
@@ -25,12 +24,7 @@ private:
|
||||
|
||||
int mAnalogValue=0; /**< moist sensor values, used for a calculation */
|
||||
HomieNode *mPlant = NULL;
|
||||
HomieSetting<long> *mSensorDry;
|
||||
HomieSetting<long> *mSensorWet;
|
||||
HomieSetting<long> *mPumpAllowedHourRangeStart;
|
||||
HomieSetting<long> *mPumpAllowedHourRangeEnd;
|
||||
HomieSetting<bool> *mPumpOnlyWhenLowLight;
|
||||
HomieSetting<long> *mPumpCooldownInHours;
|
||||
PlantSettings_t mSetting;
|
||||
|
||||
public:
|
||||
|
||||
@@ -41,7 +35,9 @@ public:
|
||||
* @param pinPump Pin of the Pump to use
|
||||
*/
|
||||
Plant(int pinSensor, int pinPump,
|
||||
int plantId);
|
||||
int plantId,
|
||||
HomieNode* plant,
|
||||
PlantSettings_t* setting);
|
||||
|
||||
/**
|
||||
* @brief Add a value, to be measured
|
||||
@@ -81,7 +77,7 @@ public:
|
||||
* @return false
|
||||
*/
|
||||
bool isPumpRequired() {
|
||||
return (this->mSensorWet != NULL) && (this->mValue < this->mSensorWet->get());
|
||||
return (this->mSetting.pSensorWet != NULL) && (this->mValue < this->mSetting.pSensorWet->get());
|
||||
}
|
||||
|
||||
HomieInternals::SendingPromise& setProperty(const String& property) const {
|
||||
|
||||