use only seconds for time units, improve self test debug
This commit is contained in:
@@ -46,9 +46,9 @@ void Plant::init(void)
|
||||
return ((candidate >= 0) && (candidate <= 23));
|
||||
});
|
||||
this->mSetting->pPumpOnlyWhenLowLight->setDefaultValue(true);
|
||||
this->mSetting->pPumpCooldownInMinutes->setDefaultValue(20); // minutes
|
||||
this->mSetting->pPumpCooldownInMinutes->setValidator([](long candidate) {
|
||||
return ((candidate >= 0) && (candidate <= 60*24*7));
|
||||
this->mSetting->pPumpCooldownInSeconds->setDefaultValue(60*60); // 1 hour
|
||||
this->mSetting->pPumpCooldownInSeconds->setValidator([](long candidate) {
|
||||
return (candidate >= 0);
|
||||
});
|
||||
|
||||
this->mSetting->pPumpDuration->setDefaultValue(5);
|
||||
@@ -71,9 +71,7 @@ void Plant::init(void)
|
||||
Serial.println("Set GPIO mode " + String(mPinSensor) + "=" + String(ANALOG));
|
||||
Serial.flush();
|
||||
pinMode(this->mPinSensor, INPUT);
|
||||
Serial.println("Set GPIO " + String(mPinPump) + "=" + String(LOW));
|
||||
Serial.flush();
|
||||
digitalWrite(this->mPinPump, LOW);
|
||||
|
||||
pcnt_unit_t unit = (pcnt_unit_t) (PCNT_UNIT_0 + this->mPlantId);
|
||||
pcnt_config_t pcnt_config = { }; // Instancia PCNT config
|
||||
|
||||
|
||||
Reference in New Issue