Merge branch 'master' of github.com:0110/PlantCtrl
This commit is contained in:
commit
703553beb4
@ -80,7 +80,7 @@
|
||||
/** \addtogroup Configuration
|
||||
* @{
|
||||
*/
|
||||
#define FIRMWARE_VERSION "2.7 HW0.10b"
|
||||
#define FIRMWARE_VERSION "2.71 HW0.10b"
|
||||
|
||||
#define TIMED_LIGHT_PIN CUSTOM1_PIN5
|
||||
#define FLOWMETER_PIN CUSTOM1_PIN1
|
||||
@ -115,7 +115,7 @@
|
||||
|
||||
#define TEMPERATUR_TIMEOUT 3000 /**< 3 Seconds timeout for the temperatures sensors */
|
||||
#define WATERSENSOR_TIMEOUT 3000 /**< 3 Seconds timeout for the water distance sensor */
|
||||
#define WATERSENSOR_CYCLE 5 /**< 5 sensor measurement are performed */
|
||||
#define WATERSENSOR_CYCLE 10 /**< 5 sensor measurement are performed */
|
||||
#define DS18B20_RESOLUTION 9 /**< 9bit temperature resolution -> 0.5°C steps */
|
||||
|
||||
#define UTC_OFFSET_DE 3600 /* UTC offset in seconds for Germany */
|
||||
|
@ -33,6 +33,9 @@
|
||||
#define LOG_VERY_COLD_WATER "Water potentially frozen, ignoring pump request"
|
||||
#define LOG_VERY_COLD_WATER_CODE -7
|
||||
|
||||
#define LOG_PUMP_FULLTANK_MESSAGE "Water Sensor distance unrealistic"
|
||||
#define LOG_PUMP_FULLTANK_CODE 3
|
||||
|
||||
//msg is dynamic defined
|
||||
#define LOG_PUMP_INEFFECTIVE -4
|
||||
#define LOG_PUMP_STARTED_CODE 10
|
||||
|
@ -51,7 +51,7 @@ extern "C" bool verifyRollbackLater(){
|
||||
* DEFINES
|
||||
******************************************************************************/
|
||||
#define AMOUNT_SENOR_QUERYS 8
|
||||
#define MAX_TANK_DEPTH 2000
|
||||
#define MAX_TANK_DEPTH 5000
|
||||
#define REBOOT_LOOP_DETECTION_ERROR 5
|
||||
|
||||
/******************************************************************************
|
||||
@ -85,7 +85,7 @@ int volatile selfTestPumpRun = -1; /** pump to run at the end of the cycle */
|
||||
bool mConfigured = false;
|
||||
long nextBlink = 0; /**< Time needed in main loop to support expected blink code */
|
||||
|
||||
RunningMedian waterRawSensor = RunningMedian(5);
|
||||
RunningMedian waterRawSensor = RunningMedian(WATERSENSOR_CYCLE);
|
||||
float mSolarVoltage = 0.0f; /**< Voltage from solar panels */
|
||||
float mBatteryVoltage = 0.0f; /**< Voltage from lipo */
|
||||
unsigned long setupFinishedTimestamp;
|
||||
@ -1146,6 +1146,10 @@ bool isLowLight = (mSolarVoltage <= SOLAR_CHARGE_MAX_VOLTAGE);
|
||||
{
|
||||
//surface of water is still nearer the sensor than required to cover the pumps
|
||||
hasWater = waterRawSensor.getAverage() < waterLevelMin.get();
|
||||
if (waterRawSensor.getAverage() > waterLevelMax.get()) {
|
||||
log(LOG_LEVEL_ERROR, LOG_PUMP_FULLTANK_MESSAGE, LOG_PUMP_FULLTANK_CODE);
|
||||
hasWater = true;
|
||||
}
|
||||
}
|
||||
|
||||
// FIXME no water warning message
|
||||
|