Merge branch 'master' of github.com:0110/PlantCtrl
This commit is contained in:
commit
68386ce02f
@ -94,7 +94,7 @@
|
||||
#define MOIST_SENSOR_MIN_FRQ 500 // 0.5kHz (500Hz margin)
|
||||
|
||||
#define ANALOG_SENSOR_MAX_MV 1300 //successive approximation of good range
|
||||
#define ANALOG_SENSOR_MIN_MV 300 //successive approximation of good range
|
||||
#define ANALOG_SENSOR_MIN_MV 100 //successive approximation of good range
|
||||
|
||||
#define SOLAR_VOLT_FACTOR 11
|
||||
#define BATTSENSOR_INDEX_SOLAR 0
|
||||
|
@ -45,6 +45,8 @@ static const char *SENSOR_STRING[] = {
|
||||
#define MISSING_SENSOR -2
|
||||
//plant uses only cooldown and duration, moisture is measured but ignored, allowedHours is ignored (eg. make a 30min on 30min off cycle)
|
||||
#define HYDROPONIC_MODE -3
|
||||
//plant uses cooldown and duration and workhours, moisture is measured but ignored
|
||||
#define TIMER_ONLY -4
|
||||
|
||||
typedef struct PlantSettings_t
|
||||
{
|
||||
|
@ -29,6 +29,9 @@
|
||||
#define LOG_PUMP_AND_DOWNLOADMODE "Download mode, ignoring pump request"
|
||||
#define LOG_PUMP_AND_DOWNLOADMODE_CODE 2
|
||||
|
||||
#define LOG_VERY_COLD_WATER "Water potentially frozen, ignoring pump request"
|
||||
#define LOG_VERY_COLD_WATER -7
|
||||
|
||||
//msg is dynamic defined
|
||||
#define LOG_PUMP_INEFFECTIVE -4
|
||||
#define LOG_PUMP_STARTED_CODE 10
|
||||
|
@ -73,6 +73,12 @@ public:
|
||||
return SENSOR_STRING[mode];
|
||||
}
|
||||
|
||||
bool isTimerOnly()
|
||||
{
|
||||
long current = this->mSetting->pSensorDry->get();
|
||||
return equalish(current, TIMER_ONLY);
|
||||
}
|
||||
|
||||
bool isHydroponic()
|
||||
{
|
||||
long current = this->mSetting->pSensorDry->get();
|
||||
@ -92,7 +98,7 @@ public:
|
||||
*/
|
||||
bool isPumpRequired()
|
||||
{
|
||||
if (isHydroponic())
|
||||
if (isHydroponic() || isTimerOnly())
|
||||
{
|
||||
// hydroponic only uses timer based controll
|
||||
return true;
|
||||
|
@ -30,7 +30,7 @@ void Plant::init(void)
|
||||
/* Initialize Home Settings validator */
|
||||
this->mSetting->pSensorDry->setDefaultValue(DEACTIVATED_PLANT);
|
||||
this->mSetting->pSensorDry->setValidator([](long candidate)
|
||||
{ return (((candidate >= 0.0) && (candidate <= 100.0)) || equalish(candidate, DEACTIVATED_PLANT) || equalish(candidate, HYDROPONIC_MODE)); });
|
||||
{ return (((candidate >= 0.0) && (candidate <= 100.0)) || equalish(candidate, DEACTIVATED_PLANT) || equalish(candidate, HYDROPONIC_MODE) || equalish(candidate, TIMER_ONLY)); });
|
||||
|
||||
this->mSetting->pPumpAllowedHourRangeStart->setDefaultValue(8); // start at 8:00
|
||||
this->mSetting->pPumpAllowedHourRangeStart->setValidator([](long candidate)
|
||||
@ -38,7 +38,7 @@ void Plant::init(void)
|
||||
this->mSetting->pPumpAllowedHourRangeEnd->setDefaultValue(20); // stop pumps at 20:00
|
||||
this->mSetting->pPumpAllowedHourRangeEnd->setValidator([](long candidate)
|
||||
{ return ((candidate >= 0) && (candidate <= 23)); });
|
||||
this->mSetting->pPumpOnlyWhenLowLight->setDefaultValue(true);
|
||||
this->mSetting->pPumpOnlyWhenLowLight->setDefaultValue(false);
|
||||
this->mSetting->pPumpCooldownInSeconds->setDefaultValue(60 * 60); // 1 hour
|
||||
this->mSetting->pPumpCooldownInSeconds->setValidator([](long candidate)
|
||||
{ return (candidate >= 0); });
|
||||
@ -263,9 +263,9 @@ void Plant::advertise(void)
|
||||
{
|
||||
// Advertise topics
|
||||
mPump = this->mPlant->advertise("switch").setName("Pump").setDatatype("Boolean");
|
||||
this->mPlant->advertise("lastPump").setName("lastPump").setDatatype("Integer").setUnit("unixtime");
|
||||
this->mPlant->advertise("moist").setName("Percent").setDatatype("Float").setUnit("%");
|
||||
this->mPlant->advertise("moistraw").setName("adc").setDatatype("Float").setUnit("3.3/4096V");
|
||||
this->mPlant->advertise("state").setName("state").setDatatype("String");
|
||||
this->mPlant->advertise("lastPump").setName("lastPump").setDatatype("Integer").setUnit("unixtime").setRetained(true);
|
||||
this->mPlant->advertise("moist").setName("Percent").setDatatype("Float").setUnit("%").setRetained(true);
|
||||
this->mPlant->advertise("moistraw").setName("adc").setDatatype("Float").setUnit("3.3/4096V").setRetained(true);
|
||||
this->mPlant->advertise("state").setName("state").setDatatype("String").setRetained(true);
|
||||
|
||||
}
|
||||
|
@ -40,7 +40,6 @@
|
||||
#include "ulp-pwm.h"
|
||||
#endif
|
||||
|
||||
|
||||
/******************************************************************************
|
||||
* DEFINES
|
||||
******************************************************************************/
|
||||
@ -56,6 +55,7 @@ int determineNextPump(bool lowLight);
|
||||
void plantcontrol();
|
||||
void readPowerSwitchedSensors();
|
||||
bool determineTimedLightState(bool lowLight);
|
||||
bool otaRunning = false;
|
||||
|
||||
/******************************************************************************
|
||||
* NON VOLATILE VARIABLES in DEEP SLEEP
|
||||
@ -90,6 +90,8 @@ long lastSendPumpUpdate = 0;
|
||||
long pumpTargetMl = -1;
|
||||
#endif
|
||||
|
||||
float waterTemp = 30;
|
||||
|
||||
/*************************** Hardware abstraction *****************************/
|
||||
|
||||
OneWire oneWire(SENSOR_ONEWIRE);
|
||||
@ -267,6 +269,7 @@ void readOneWireSensors()
|
||||
{
|
||||
mqttWrite(&sensorTemp, TEMPERATUR_SENSOR_WATER, String(temp));
|
||||
Serial << "Water Temperatur " << temp << " °C " << endl;
|
||||
waterTemp = temp;
|
||||
}
|
||||
/* Always send the sensor address with the temperatur value */
|
||||
mqttWrite(&sensorTemp, String(buf), String(temp));
|
||||
@ -401,10 +404,7 @@ void onHomieEvent(const HomieEvent &event)
|
||||
{
|
||||
mPlants[i].deactivatePump();
|
||||
}
|
||||
WRITE_PERI_REG(RTC_CNTL_BROWN_OUT_REG, 0);
|
||||
digitalWrite(OUTPUT_ENABLE_PUMP, HIGH);
|
||||
delay(100);
|
||||
WRITE_PERI_REG(RTC_CNTL_BROWN_OUT_REG, 1);
|
||||
otaRunning = true;
|
||||
mDownloadMode = true;
|
||||
break;
|
||||
case HomieEventType::OTA_SUCCESSFUL:
|
||||
@ -461,7 +461,7 @@ int determineNextPump(bool isLowLight)
|
||||
log(LOG_LEVEL_DEBUG, String(String(i) + " No pump required: due to light"), LOG_DEBUG_CODE);
|
||||
continue;
|
||||
}
|
||||
if (!plant.isHydroponic())
|
||||
if (! (plant.isHydroponic() || plant.isTimerOnly()))
|
||||
{
|
||||
if (equalish(plant.getCurrentMoistureRaw(), MISSING_SENSOR))
|
||||
{
|
||||
@ -493,10 +493,9 @@ int determineNextPump(bool isLowLight)
|
||||
}else {
|
||||
plant.publishState("active");
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
if (!plant.isHydroponic())
|
||||
if (! (plant.isHydroponic() || plant.isTimerOnly()))
|
||||
{
|
||||
consecutiveWateringPlant[i]++;
|
||||
}
|
||||
@ -676,7 +675,6 @@ long duration = millis() - pumpStartTime;
|
||||
log(LOG_LEVEL_ERROR, LOG_HARDWARECOUNTER_ERROR_MESSAGE, LOG_HARDWARECOUNTER_ERROR_CODE);
|
||||
targetReached = true;
|
||||
log(LOG_LEVEL_INFO, "Reached pump target ml " + String(pumpToRun), LOG_PUMP_STARTED_CODE);
|
||||
|
||||
}
|
||||
else
|
||||
{
|
||||
@ -697,7 +695,6 @@ long duration = millis() - pumpStartTime;
|
||||
}
|
||||
#endif
|
||||
|
||||
|
||||
if (millis() > pumpTarget)
|
||||
{
|
||||
mPlants[pumpToRun].setProperty("watertime").send(String(duration));
|
||||
@ -753,12 +750,14 @@ void safeSetup()
|
||||
|
||||
pinMode(OUTPUT_ENABLE_SENSOR, OUTPUT);
|
||||
|
||||
static_assert(HomieInternals::MAX_CONFIG_SETTING_SIZE >= MAX_CONFIG_SETTING_ITEMS, "Limits.hpp not adjusted MAX_CONFIG_SETTING_ITEMS");
|
||||
if (HomieInternals::MAX_CONFIG_SETTING_SIZE < MAX_CONFIG_SETTING_ITEMS)
|
||||
{
|
||||
// increase the config settings
|
||||
Serial << "Limits.hpp is not adjusted, please search for this string and increase" << endl;
|
||||
return;
|
||||
}
|
||||
static_assert(HomieInternals::MAX_JSON_CONFIG_FILE_SIZE >= MAX_JSON_CONFIG_FILE_SIZE_CUSTOM, "Limits.hpp not adjusted MAX_JSON_CONFIG_FILE_SIZE");
|
||||
if (HomieInternals::MAX_JSON_CONFIG_FILE_SIZE < MAX_JSON_CONFIG_FILE_SIZE_CUSTOM)
|
||||
{
|
||||
// increase the config settings
|
||||
@ -809,14 +808,12 @@ void safeSetup()
|
||||
}
|
||||
readPowerSwitchedSensors();
|
||||
|
||||
|
||||
Homie.setup();
|
||||
|
||||
Wire = TwoWire(0);
|
||||
Wire.setPins(SENSOR_TANK_SDA, SENSOR_TANK_SCL);
|
||||
Wire.begin();
|
||||
|
||||
|
||||
/************************* Start One-Wire bus ***************/
|
||||
int tempInitStartTime = millis();
|
||||
uint8_t sensorCount = 0U;
|
||||
@ -981,7 +978,14 @@ void loop()
|
||||
digitalWrite(OUTPUT_ENABLE_SENSOR, !digitalRead(OUTPUT_ENABLE_SENSOR));
|
||||
if (mConfigured)
|
||||
{
|
||||
nextBlink = millis() + 500;
|
||||
if (otaRunning)
|
||||
{
|
||||
nextBlink = millis() + 100;
|
||||
}
|
||||
else
|
||||
{
|
||||
nextBlink = millis() + 501;
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
@ -1078,12 +1082,14 @@ void plantcontrol()
|
||||
|
||||
#endif // TIMED_LIGHT_PIN
|
||||
|
||||
bool isLiquid = waterTemp > 5;
|
||||
bool hasWater = true; // FIXME remaining > waterLevelMin.get();
|
||||
// FIXME no water warning message
|
||||
pumpToRun = determineNextPump(isLowLight);
|
||||
// early aborts
|
||||
if (pumpToRun != -1)
|
||||
{
|
||||
if(isLiquid){
|
||||
if (hasWater)
|
||||
{
|
||||
if (mDownloadMode)
|
||||
@ -1098,6 +1104,11 @@ void plantcontrol()
|
||||
pumpToRun = -1;
|
||||
}
|
||||
}
|
||||
else{
|
||||
log(LOG_LEVEL_ERROR, LOG_PUMP_BUTNOTANK_MESSAGE, LOG_PUMP_BUTNOTANK_CODE);
|
||||
pumpToRun = -1;
|
||||
}
|
||||
}
|
||||
|
||||
// go directly to sleep, skipping the pump loop
|
||||
if (pumpToRun == -1)
|
||||
@ -1129,9 +1140,11 @@ bool determineTimedLightState(bool lowLight)
|
||||
}
|
||||
|
||||
int curHour = getCurrentHour();
|
||||
|
||||
bool condition1 = ((hoursStart > hoursEnd) &&
|
||||
(curHour >= hoursStart || curHour <= hoursEnd));
|
||||
bool condition2 = /* Handle e.g. start = 8, end = 21 */
|
||||
|
||||
((hoursStart < hoursEnd) &&
|
||||
(curHour >= hoursStart && curHour <= hoursEnd));
|
||||
timedLightNode.setProperty("debug").send(String(curHour) + " " + String(hoursStart) + " " + String(hoursEnd) + " " + String(condition1) + " " + String(condition2));
|
||||
|
Loading…
Reference in New Issue