Stop pumps due to water sensor
This commit is contained in:
parent
704684d437
commit
5df69f20a8
@ -1095,7 +1095,12 @@ bool isLowLight = mSolarVoltage <= 9;
|
|||||||
#endif // TIMED_LIGHT_PIN
|
#endif // TIMED_LIGHT_PIN
|
||||||
|
|
||||||
bool isLiquid = waterTemp > 5;
|
bool isLiquid = waterTemp > 5;
|
||||||
bool hasWater = true; // FIXME remaining > waterLevelMin.get();
|
bool hasWater = true; // By default activate the pump
|
||||||
|
if (waterRawSensor.getCount() > 0)
|
||||||
|
{
|
||||||
|
hasWater = ( (waterLevelMax.get() - waterRawSensor.getAverage()) > waterLevelMin.get() );
|
||||||
|
}
|
||||||
|
|
||||||
// FIXME no water warning message
|
// FIXME no water warning message
|
||||||
pumpToRun = determineNextPump(isLowLight);
|
pumpToRun = determineNextPump(isLowLight);
|
||||||
// early aborts
|
// early aborts
|
||||||
@ -1108,6 +1113,8 @@ bool isLowLight = mSolarVoltage <= 9;
|
|||||||
{
|
{
|
||||||
log(LOG_LEVEL_INFO, LOG_PUMP_AND_DOWNLOADMODE, LOG_PUMP_AND_DOWNLOADMODE_CODE);
|
log(LOG_LEVEL_INFO, LOG_PUMP_AND_DOWNLOADMODE, LOG_PUMP_AND_DOWNLOADMODE_CODE);
|
||||||
pumpToRun = -1;
|
pumpToRun = -1;
|
||||||
|
} else {
|
||||||
|
/* Pump can be used :) */
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
else
|
else
|
||||||
@ -1116,8 +1123,9 @@ bool isLowLight = mSolarVoltage <= 9;
|
|||||||
pumpToRun = -1;
|
pumpToRun = -1;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
else{
|
else
|
||||||
log(LOG_LEVEL_ERROR, LOG_VERY_COLD_WATER, LOG_VERY_COLD_WATER_CODE);
|
{
|
||||||
|
log(LOG_LEVEL_ERROR, LOG_VERY_COLD_WATER, LOG_VERY_COLD_WATER_CODE);
|
||||||
pumpToRun = -1;
|