Stop pumps due to water sensor

This commit is contained in:
Ollo 2023-03-24 18:40:57 +01:00
parent 704684d437
commit 5df69f20a8

View File

@ -1095,7 +1095,12 @@ bool isLowLight = mSolarVoltage <= 9;
#endif // TIMED_LIGHT_PIN #endif // TIMED_LIGHT_PIN
bool isLiquid = waterTemp > 5; bool isLiquid = waterTemp > 5;
bool hasWater = true; // FIXME remaining > waterLevelMin.get(); bool hasWater = true; // By default activate the pump
if (waterRawSensor.getCount() > 0)
{
hasWater = ( (waterLevelMax.get() - waterRawSensor.getAverage()) > waterLevelMin.get() );
}
// FIXME no water warning message // FIXME no water warning message
pumpToRun = determineNextPump(isLowLight); pumpToRun = determineNextPump(isLowLight);
// early aborts // early aborts
@ -1108,6 +1113,8 @@ bool isLowLight = mSolarVoltage <= 9;
{ {
log(LOG_LEVEL_INFO, LOG_PUMP_AND_DOWNLOADMODE, LOG_PUMP_AND_DOWNLOADMODE_CODE); log(LOG_LEVEL_INFO, LOG_PUMP_AND_DOWNLOADMODE, LOG_PUMP_AND_DOWNLOADMODE_CODE);
pumpToRun = -1; pumpToRun = -1;
} else {
/* Pump can be used :) */
} }
} }
else else
@ -1116,8 +1123,9 @@ bool isLowLight = mSolarVoltage <= 9;
pumpToRun = -1; pumpToRun = -1;
} }
} }
else{ else
log(LOG_LEVEL_ERROR, LOG_VERY_COLD_WATER, LOG_VERY_COLD_WATER_CODE); {
log(LOG_LEVEL_ERROR, LOG_VERY_COLD_WATER, LOG_VERY_COLD_WATER_CODE);
pumpToRun = -1; pumpToRun = -1;
} }
} }