formating only
This commit is contained in:
parent
15e96a4990
commit
5dedc76727
@ -12,7 +12,7 @@
|
||||
|
||||
/******************************************************************************
|
||||
* INCLUDES
|
||||
******************************************************************************/
|
||||
******************************************************************************/
|
||||
#include "LogDefines.h"
|
||||
#include "FileUtils.h"
|
||||
#include "TimeUtils.h"
|
||||
@ -37,20 +37,19 @@
|
||||
#include "MQTTUtils.h"
|
||||
#include "esp_ota_ops.h"
|
||||
#if defined(TIMED_LIGHT_PIN)
|
||||
#include "ulp-pwm.h"
|
||||
#include "ulp-pwm.h"
|
||||
#endif
|
||||
|
||||
|
||||
/******************************************************************************
|
||||
* DEFINES
|
||||
******************************************************************************/
|
||||
******************************************************************************/
|
||||
#define AMOUNT_SENOR_QUERYS 8
|
||||
#define MAX_TANK_DEPTH 2000
|
||||
#define REBOOT_LOOP_DETECTION_ERROR 5
|
||||
|
||||
/******************************************************************************
|
||||
* FUNCTION PROTOTYPES
|
||||
******************************************************************************/
|
||||
******************************************************************************/
|
||||
|
||||
int determineNextPump(bool lowLight);
|
||||
void plantcontrol();
|
||||
@ -60,7 +59,7 @@ bool otaRunning = false;
|
||||
|
||||
/******************************************************************************
|
||||
* NON VOLATILE VARIABLES in DEEP SLEEP
|
||||
******************************************************************************/
|
||||
******************************************************************************/
|
||||
#if defined(TIMED_LIGHT_PIN)
|
||||
RTC_DATA_ATTR bool timedLightLowVoltageTriggered = false; /**remember if it was shut down due to voltage level */
|
||||
#endif // TIMED_LIGHT_PIN
|
||||
@ -70,7 +69,7 @@ RTC_DATA_ATTR long consecutiveWateringPlant[MAX_PLANTS] = {0};
|
||||
|
||||
/******************************************************************************
|
||||
* LOCAL VARIABLES
|
||||
******************************************************************************/
|
||||
******************************************************************************/
|
||||
bool volatile mDownloadMode = false; /**< Controller must not sleep */
|
||||
bool volatile mSensorsRead = false; /**< Sensors are read without Wifi or MQTT */
|
||||
int volatile pumpToRun = -1; /** pump to run at the end of the cycle */
|
||||
@ -131,7 +130,7 @@ Plant mPlants[MAX_PLANTS] = {
|
||||
|
||||
/******************************************************************************
|
||||
* LOCAL FUNCTIONS
|
||||
******************************************************************************/
|
||||
******************************************************************************/
|
||||
|
||||
void finsihedCycleSucessfully()
|
||||
{
|
||||
@ -153,7 +152,7 @@ void espDeepSleep(bool afterPump = false)
|
||||
if (mDownloadMode)
|
||||
{
|
||||
log(LOG_LEVEL_DEBUG, "abort deepsleep, DownloadMode active", LOG_DEBUG_CODE);
|
||||
//if we manage to get to the download mode, the device can be restored
|
||||
// if we manage to get to the download mode, the device can be restored
|
||||
finsihedCycleSucessfully();
|
||||
return;
|
||||
}
|
||||
@ -213,7 +212,7 @@ void espDeepSleep(bool afterPump = false)
|
||||
}
|
||||
}
|
||||
|
||||
//requires homie being started
|
||||
// requires homie being started
|
||||
void readOneWireSensors()
|
||||
{
|
||||
for (uint8_t i = 0; i < sensors.getDeviceCount(); i++)
|
||||
@ -241,7 +240,7 @@ void readOneWireSensors()
|
||||
|
||||
if (!valid)
|
||||
{
|
||||
//wrong family or crc errors on each retry
|
||||
// wrong family or crc errors on each retry
|
||||
continue;
|
||||
}
|
||||
|
||||
@ -316,16 +315,18 @@ void readPowerSwitchedSensors()
|
||||
Plant plant = mPlants[i];
|
||||
switch (plant.getSensorMode())
|
||||
{
|
||||
case CAPACITIVE_FREQUENCY: {
|
||||
case CAPACITIVE_FREQUENCY:
|
||||
{
|
||||
Serial << "Plant " << i << " measurement: " << mPlants[i].getCurrentMoistureRaw() << " hz " << mPlants[i].getCurrentMoisturePCT() << "%" << endl;
|
||||
break;
|
||||
}
|
||||
case ANALOG_RESISTANCE_PROBE : {
|
||||
case ANALOG_RESISTANCE_PROBE:
|
||||
{
|
||||
Serial << "Plant " << i << " measurement: " << mPlants[i].getCurrentMoistureRaw() << " mV " << mPlants[i].getCurrentMoisturePCT() << "%" << endl;
|
||||
break;
|
||||
}
|
||||
case NONE : {
|
||||
|
||||
case NONE:
|
||||
{
|
||||
}
|
||||
}
|
||||
}
|
||||
@ -486,12 +487,14 @@ int determineNextPump(bool isLowLight)
|
||||
}
|
||||
else
|
||||
{
|
||||
if(mDownloadMode){
|
||||
if (mDownloadMode)
|
||||
{
|
||||
plant.publishState("active+supressed");
|
||||
}else {
|
||||
}
|
||||
else
|
||||
{
|
||||
plant.publishState("active");
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
if (!plant.isHydroponic())
|
||||
@ -520,7 +523,7 @@ int determineNextPump(bool isLowLight)
|
||||
else
|
||||
{
|
||||
plant.publishState("wet");
|
||||
//plant was detected as wet, remove consecutive count
|
||||
// plant was detected as wet, remove consecutive count
|
||||
consecutiveWateringPlant[i] = 0;
|
||||
}
|
||||
}
|
||||
@ -606,12 +609,12 @@ bool switch7(const HomieRange &range, const String &value)
|
||||
|
||||
void initPumpLogic()
|
||||
{
|
||||
//set targets
|
||||
// set targets
|
||||
|
||||
#ifdef FLOWMETER_PIN
|
||||
pumpTargetMl = mPlants[pumpToRun].getPumpMl();
|
||||
|
||||
//0-6 are used for moisture measurment
|
||||
// 0-6 are used for moisture measurment
|
||||
pcnt_unit_t unit = (pcnt_unit_t)(PCNT_UNIT_7);
|
||||
pcnt_config_t pcnt_config = {}; // Instancia PCNT config
|
||||
pcnt_config.pulse_gpio_num = FLOWMETER_PIN; // Configura GPIO para entrada dos pulsos
|
||||
@ -630,14 +633,13 @@ void initPumpLogic()
|
||||
#endif
|
||||
pumpStartTime = millis();
|
||||
pumpTarget = millis() + (mPlants[pumpToRun].getPumpDuration() * 1000);
|
||||
#ifdef FLOWMETER_PIN
|
||||
#ifdef FLOWMETER_PIN
|
||||
log(LOG_LEVEL_INFO, "Starting pump " + String(pumpToRun) + " for " + String(mPlants[pumpToRun].getPumpDuration()) + "s or " + String(pumpTargetMl) + "ml", LOG_PUMP_STARTED_CODE);
|
||||
#else
|
||||
#else
|
||||
log(LOG_LEVEL_INFO, "Starting pump " + String(pumpToRun) + " for " + String(mPlants[pumpToRun].getPumpDuration()) + "s", LOG_PUMP_STARTED_CODE);
|
||||
#endif
|
||||
#endif
|
||||
|
||||
|
||||
//enable power
|
||||
// enable power
|
||||
WRITE_PERI_REG(RTC_CNTL_BROWN_OUT_REG, 0);
|
||||
digitalWrite(OUTPUT_ENABLE_PUMP, HIGH);
|
||||
delay(100);
|
||||
@ -664,7 +666,7 @@ void pumpActiveLoop()
|
||||
mqttUpdateTick = true;
|
||||
}
|
||||
|
||||
long duration = millis() - pumpStartTime;
|
||||
long duration = millis() - pumpStartTime;
|
||||
#ifdef FLOWMETER_PIN
|
||||
int16_t pulses;
|
||||
pcnt_unit_t unit = (pcnt_unit_t)(PCNT_UNIT_7);
|
||||
@ -674,11 +676,10 @@ long duration = millis() - pumpStartTime;
|
||||
log(LOG_LEVEL_ERROR, LOG_HARDWARECOUNTER_ERROR_MESSAGE, LOG_HARDWARECOUNTER_ERROR_CODE);
|
||||
targetReached = true;
|
||||
log(LOG_LEVEL_INFO, "Reached pump target ml " + String(pumpToRun), LOG_PUMP_STARTED_CODE);
|
||||
|
||||
}
|
||||
else
|
||||
{
|
||||
float mLPumped = pulses/FLOWMETER_PULSES_PER_ML; //mLperMs*duration;
|
||||
float mLPumped = pulses / FLOWMETER_PULSES_PER_ML; // mLperMs*duration;
|
||||
if (mLPumped >= pumpTargetMl)
|
||||
{
|
||||
targetReached = true;
|
||||
@ -695,7 +696,6 @@ long duration = millis() - pumpStartTime;
|
||||
}
|
||||
#endif
|
||||
|
||||
|
||||
if (millis() > pumpTarget)
|
||||
{
|
||||
mPlants[pumpToRun].setProperty("watertime").send(String(duration));
|
||||
@ -709,12 +709,12 @@ long duration = millis() - pumpStartTime;
|
||||
if (targetReached)
|
||||
{
|
||||
|
||||
//disable all
|
||||
// disable all
|
||||
digitalWrite(OUTPUT_ENABLE_PUMP, LOW);
|
||||
mPlants[pumpToRun].deactivatePump();
|
||||
//disable loop, to prevent multi processing
|
||||
// disable loop, to prevent multi processing
|
||||
pumpStarted = false;
|
||||
//if runtime is larger than cooldown, else it would run continously
|
||||
// if runtime is larger than cooldown, else it would run continously
|
||||
rtcLastWateringPlant[pumpToRun] = getCurrentTime();
|
||||
espDeepSleep(true);
|
||||
}
|
||||
@ -731,7 +731,7 @@ void safeSetup()
|
||||
WiFi.mode(WIFI_OFF);
|
||||
Serial.flush();
|
||||
|
||||
//restore state before releasing pin, to prevent flickering
|
||||
// restore state before releasing pin, to prevent flickering
|
||||
#if defined(TIMED_LIGHT_PIN)
|
||||
ulp_pwm_init();
|
||||
#endif // TIMED_LIGHT_PIN
|
||||
@ -754,14 +754,14 @@ void safeSetup()
|
||||
static_assert(HomieInternals::MAX_CONFIG_SETTING_SIZE >= MAX_CONFIG_SETTING_ITEMS, "Limits.hpp not adjusted MAX_CONFIG_SETTING_ITEMS");
|
||||
if (HomieInternals::MAX_CONFIG_SETTING_SIZE < MAX_CONFIG_SETTING_ITEMS)
|
||||
{
|
||||
//increase the config settings
|
||||
// increase the config settings
|
||||
Serial << "Limits.hpp is not adjusted, please search for this string and increase" << endl;
|
||||
return;
|
||||
}
|
||||
static_assert(HomieInternals::MAX_JSON_CONFIG_FILE_SIZE >= MAX_JSON_CONFIG_FILE_SIZE_CUSTOM, "Limits.hpp not adjusted MAX_JSON_CONFIG_FILE_SIZE");
|
||||
if (HomieInternals::MAX_JSON_CONFIG_FILE_SIZE < MAX_JSON_CONFIG_FILE_SIZE_CUSTOM)
|
||||
{
|
||||
//increase the config settings
|
||||
// increase the config settings
|
||||
Serial << "Limits.hpp is not adjusted, please search for this string and increase" << endl;
|
||||
return;
|
||||
}
|
||||
@ -772,7 +772,7 @@ void safeSetup()
|
||||
Homie_setBrand("PlantControl");
|
||||
// Set default values
|
||||
|
||||
//in seconds
|
||||
// in seconds
|
||||
deepSleepTime.setDefaultValue(600).setValidator([](long candidate)
|
||||
{ return (candidate > 0) && (candidate < (60 * 60 * 2) /** 2h max sleep */); });
|
||||
deepSleepNightTime.setDefaultValue(600);
|
||||
@ -809,14 +809,12 @@ void safeSetup()
|
||||
}
|
||||
readPowerSwitchedSensors();
|
||||
|
||||
|
||||
Homie.setup();
|
||||
|
||||
Wire = TwoWire(0);
|
||||
Wire.setPins(SENSOR_TANK_SDA, SENSOR_TANK_SCL);
|
||||
Wire.begin();
|
||||
|
||||
|
||||
/************************* Start One-Wire bus ***************/
|
||||
int tempInitStartTime = millis();
|
||||
uint8_t sensorCount = 0U;
|
||||
@ -835,7 +833,7 @@ void safeSetup()
|
||||
/* Measure temperature TODO idea: move this into setup */
|
||||
if (sensorCount > 0)
|
||||
{
|
||||
//sensors.setResolution(DS18B20_RESOLUTION);
|
||||
// sensors.setResolution(DS18B20_RESOLUTION);
|
||||
sensors.requestTemperatures();
|
||||
}
|
||||
|
||||
@ -905,7 +903,7 @@ void safeSetup()
|
||||
}
|
||||
|
||||
readOneWireSensors();
|
||||
//prevent BOD to be paranoid
|
||||
// prevent BOD to be paranoid
|
||||
WRITE_PERI_REG(RTC_CNTL_BROWN_OUT_REG, 0);
|
||||
digitalWrite(OUTPUT_ENABLE_PUMP, HIGH);
|
||||
delay(100);
|
||||
@ -1077,18 +1075,21 @@ void plantcontrol()
|
||||
#if defined(TIMED_LIGHT_PIN)
|
||||
bool isLowLight = mSolarVoltage <= 9;
|
||||
bool shouldLight = determineTimedLightState(isLowLight);
|
||||
if(shouldLight){
|
||||
if (shouldLight)
|
||||
{
|
||||
ulp_pwm_set_level(timedLightPowerLevel.get());
|
||||
}else {
|
||||
}
|
||||
else
|
||||
{
|
||||
ulp_pwm_set_level(0);
|
||||
}
|
||||
|
||||
#endif // TIMED_LIGHT_PIN
|
||||
|
||||
bool hasWater = true; //FIXME remaining > waterLevelMin.get();
|
||||
//FIXME no water warning message
|
||||
bool hasWater = true; // FIXME remaining > waterLevelMin.get();
|
||||
// FIXME no water warning message
|
||||
pumpToRun = determineNextPump(isLowLight);
|
||||
//early aborts
|
||||
// early aborts
|
||||
if (pumpToRun != -1)
|
||||
{
|
||||
if (hasWater)
|
||||
@ -1122,7 +1123,7 @@ bool determineTimedLightState(bool lowLight)
|
||||
long hoursStart = timedLightStart.get();
|
||||
long hoursEnd = timedLightEnd.get();
|
||||
|
||||
//ntp missing
|
||||
// ntp missing
|
||||
if (getCurrentTime() < 10000)
|
||||
{
|
||||
timedLightNode.setProperty("state").send(String("Off, missing ntp"));
|
||||
|
Loading…
Reference in New Issue
Block a user