add pump current configuration
This commit is contained in:
@@ -118,6 +118,9 @@ pub struct PlantConfig {
|
||||
pub max_consecutive_pump_count: u8,
|
||||
pub moisture_sensor_min_frequency: Option<f32>, // Optional min frequency
|
||||
pub moisture_sensor_max_frequency: Option<f32>, // Optional max frequency
|
||||
pub min_pump_current_ma: u16,
|
||||
pub max_pump_current_ma: u16,
|
||||
pub ignore_current_error: bool,
|
||||
}
|
||||
|
||||
impl Default for PlantConfig {
|
||||
@@ -134,6 +137,9 @@ impl Default for PlantConfig {
|
||||
max_consecutive_pump_count: 10,
|
||||
moisture_sensor_min_frequency: None, // No override by default
|
||||
moisture_sensor_max_frequency: None, // No override by default
|
||||
min_pump_current_ma: 10,
|
||||
max_pump_current_ma: 3000,
|
||||
ignore_current_error: true,
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user