added raw moisture, improved pct calc , formating
This commit is contained in:
@@ -45,18 +45,18 @@ HomieSetting<long> waterLevelMax("watermaxlevel", "distance (mm) at maximum wate
|
||||
HomieSetting<long> waterLevelMin("waterminlevel", "distance (mm) at minimum water level (pumps still covered)");
|
||||
HomieSetting<long> waterLevelWarn("waterlevelwarn", "warn (mm) if below this water level %");
|
||||
HomieSetting<long> waterLevelVol("waterVolume", "(ml) between minimum and maximum");
|
||||
HomieSetting<const char *>ntpServer("ntpServer", "NTP server (pool.ntp.org as default)");
|
||||
HomieSetting<const char *> ntpServer("ntpServer", "NTP server (pool.ntp.org as default)");
|
||||
|
||||
/** Plant specific ones */
|
||||
|
||||
#define GENERATE_PLANT(plant, strplant) \
|
||||
HomieSetting<long> mSensorDry##plant = HomieSetting<long>("moistdry" strplant, "Plant " strplant "- Moist sensor dry threshold"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("rangehourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("rangehourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
|
||||
#define GENERATE_PLANT(plant, strplant) \
|
||||
HomieSetting<long> mSensorDry##plant = HomieSetting<long>("moistdry" strplant, "Plant " strplant "- Moist sensor dry threshold"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("rangehourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("rangehourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
|
||||
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("onlyWhenLowLightZ" strplant, "Plant" strplant " - Enable the Pump only, when there is light but not enought to charge battery"); \
|
||||
HomieSetting<long> mPumpCooldownInHours##plant = HomieSetting<long>("cooldownpump" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
|
||||
PlantSettings_t mSetting##plant = { &mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInHours##plant };
|
||||
|
||||
HomieSetting<long> mPumpCooldownInHours##plant = HomieSetting<long>("cooldownpump" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
|
||||
PlantSettings_t mSetting##plant = {&mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInHours##plant};
|
||||
|
||||
GENERATE_PLANT(0, "0");
|
||||
GENERATE_PLANT(1, "1");
|
||||
GENERATE_PLANT(2, "2");
|
||||
@@ -65,6 +65,4 @@ GENERATE_PLANT(4, "4");
|
||||
GENERATE_PLANT(5, "5");
|
||||
GENERATE_PLANT(6, "6");
|
||||
|
||||
|
||||
|
||||
#endif /* HOMIE_PLANT_CONFIG_H */
|
||||
Reference in New Issue