added initial support for hydroponic systems, changed cooldown to use minutes
This commit is contained in:
@@ -104,9 +104,9 @@ HomieSetting<const char *> ntpServer("ntpServer", "NTP server (pool.ntp.org as d
|
||||
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("hourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("hourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
|
||||
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("lowLight" strplant, "Plant" strplant " - Enable the Pump only, when there is no sunlight"); \
|
||||
HomieSetting<long> mPumpCooldownInHours##plant = HomieSetting<long>("delay" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
|
||||
HomieSetting<long> mPumpCooldownInMinutes##plant = HomieSetting<long>("delay" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
|
||||
HomieSetting<long> pPumpDuration##plant = HomieSetting<long>("pumpDuration" strplant, "Plant" strplant " - time seconds or ml (if using flowmeter) to water when pump is active"); \
|
||||
PlantSettings_t mSetting##plant = {&mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInHours##plant, &pPumpDuration##plant}; \
|
||||
PlantSettings_t mSetting##plant = {&mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInMinutes##plant, &pPumpDuration##plant}; \
|
||||
/**< Generate all settings for one plant \
|
||||
* \
|
||||
* Feature to start pumping only at morning: @link{SOLAR_CHARGE_MIN_VOLTAGE} and @link{SOLAR_CHARGE_MAX_VOLTAGE} \
|
||||
|
@@ -13,8 +13,12 @@
|
||||
|
||||
#include <Homie.h>
|
||||
|
||||
//plant pump is deactivated, but sensor values are still recorded and published
|
||||
#define DEACTIVATED_PLANT -1
|
||||
//special value to indicate a missing sensor when the plant is not deactivated but no valid sensor value was read
|
||||
#define MISSING_SENSOR -2
|
||||
//plant uses only cooldown and duration, moisture is measured but ignored, allowedHours is ignored (eg. make a 30min on 30min off cycle)
|
||||
#define HYDROPONIC_MODE -3
|
||||
|
||||
typedef struct PlantSettings_t
|
||||
{
|
||||
@@ -22,7 +26,7 @@ typedef struct PlantSettings_t
|
||||
HomieSetting<long> *pPumpAllowedHourRangeStart;
|
||||
HomieSetting<long> *pPumpAllowedHourRangeEnd;
|
||||
HomieSetting<bool> *pPumpOnlyWhenLowLight;
|
||||
HomieSetting<long> *pPumpCooldownInHours;
|
||||
HomieSetting<long> *pPumpCooldownInMinutes;
|
||||
HomieSetting<long> *pPumpDuration;
|
||||
} PlantSettings_t;
|
||||
|
||||
|
@@ -61,6 +61,12 @@ public:
|
||||
|
||||
void activatePump(void);
|
||||
|
||||
|
||||
bool isHydroponic(){
|
||||
long current = this->mSetting->pSensorDry->get();
|
||||
return !equalish(current,HYDROPONIC_MODE);
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Check if a plant is too dry and needs some water.
|
||||
*
|
||||
@@ -69,11 +75,17 @@ public:
|
||||
*/
|
||||
bool isPumpRequired()
|
||||
{
|
||||
if(isHydroponic()){
|
||||
//hydroponic only uses timer based controll
|
||||
return true;
|
||||
}
|
||||
bool isDry = getCurrentMoisture() > getSetting2Moisture();
|
||||
bool isActive = isPumpTriggerActive();
|
||||
return isDry && isActive;
|
||||
}
|
||||
|
||||
|
||||
|
||||
bool isPumpTriggerActive()
|
||||
{
|
||||
long current = this->mSetting->pSensorDry->get();
|
||||
@@ -110,7 +122,7 @@ public:
|
||||
void init(void);
|
||||
|
||||
long getCooldownInSeconds() {
|
||||
return this->mSetting->pPumpCooldownInHours->get()*60*60;
|
||||
return this->mSetting->pPumpCooldownInMinutes->get()*60;
|
||||
}
|
||||
|
||||
/**
|
||||
|
Reference in New Issue