Handle cooldown time for watering; add start and end time when pumping is allowed
This commit is contained in:
@@ -91,7 +91,7 @@ HomieSetting<const char *> ntpServer("ntpServer", "NTP server (pool.ntp.org as d
|
||||
HomieSetting<long> mSensorDry##plant = HomieSetting<long>("moistdry" strplant, "Plant " strplant "- Moist sensor dry threshold"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("rangehourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
|
||||
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("rangehourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
|
||||
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("onlyWhenLowLightZ" strplant, "Plant" strplant " - Enable the Pump only, when there is light but not enought to charge battery"); \
|
||||
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("onlyWhenLowLightZ" strplant, "Plant" strplant " - Enable the Pump only, when there is no sunlight"); \
|
||||
HomieSetting<long> mPumpCooldownInHours##plant = HomieSetting<long>("cooldownpump" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
|
||||
PlantSettings_t mSetting##plant = {&mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInHours##plant}; \
|
||||
/**< Generate all settings for one plant \
|
||||
|
@@ -98,23 +98,26 @@ public:
|
||||
|
||||
void init(void);
|
||||
|
||||
/** @fn bool isInCooldown(long sinceLastActivation)
|
||||
* @brief determine, if the plant was recently casted
|
||||
* @param sinceLastActivation timestamp of last time
|
||||
*/
|
||||
bool isInCooldown(long sinceLastActivation)
|
||||
{
|
||||
/* if the time difference is greater than one month, we know these are initial values */
|
||||
if (sinceLastActivation > (60 * 60 * 24 * 30))
|
||||
{
|
||||
return false;
|
||||
}
|
||||
|
||||
return (getCooldownInSeconds() > sinceLastActivation);
|
||||
long getCooldownInSeconds() {
|
||||
return this->mSetting->pPumpCooldownInHours->get()*60*60;
|
||||
}
|
||||
|
||||
long getCooldownInSeconds(){
|
||||
return this->mSetting->pPumpCooldownInHours->get()*60*60;
|
||||
/**
|
||||
* @brief Get the Hours when pumping should start
|
||||
*
|
||||
* @return hour
|
||||
*/
|
||||
int getHoursStart() {
|
||||
return this->mSetting->pPumpAllowedHourRangeStart->get();
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Get the Hours when pumping should end
|
||||
*
|
||||
* @return hour
|
||||
*/
|
||||
int getHoursEnd() {
|
||||
return this->mSetting->pPumpAllowedHourRangeEnd->get();
|
||||
}
|
||||
|
||||
bool isAllowedOnlyAtLowLight(void)
|
||||
|
Reference in New Issue