Refactored code

This commit is contained in:
c3ma 2020-10-23 16:20:34 +02:00
parent f29a5e3d0b
commit 3e3eaa96e4
4 changed files with 100 additions and 156 deletions

View File

@ -1,4 +1,5 @@
(sym_lib_table
(lib (name LP38690DT-3.3)(type Legacy)(uri ${KIPRJMOD}/kicad-stuff/LP38690DT-3.3.lib)(options "")(descr ""))
(lib (name ESP32-DEVKITC-32D)(type Legacy)(uri ${KIPRJMOD}/kicad-stuff/ESP32/ESP32-DEVKITC-32D.lib)(options "")(descr ""))
(lib (name PlantCtrlESP32-rescue)(type Legacy)(uri ${KIPRJMOD}/PlantCtrlESP32-rescue.lib)(options "")(descr ""))
)

View File

@ -20,12 +20,12 @@ class Plant {
private:
RunningMedian moistureRaw = RunningMedian(5);
HomieNode* mPlant = NULL;
public:
//FIXME visibility
int mPinSensor=0; /**< Pin of the moist sensor */
int mPinPump=0; /**< Pin of the pump */
PlantSettings_t* mSetting;
bool mConnected = false;
public:
/**
* @brief Construct a new Plant object
*
@ -37,29 +37,22 @@ public:
HomieNode* plant,
PlantSettings_t* setting);
/**
* @brief Add a value, to be measured
*
* @param analogValue
*/
void addSenseValue(int analogValue);
void postMQTTconnection(void);
void advertise(void);
/**
* @brief Get the Sensor Pin of the analog measuring
* @brief Measure a new analog moister value
*
* @return int
*/
int getSensorPin() { return mPinSensor; }
/**
* @brief Get the Pump Pin object
*
* @return int
*/
int getPumpPin() { return mPinPump; }
void addSenseValue(void);
int getSensorValue() { return moistureRaw.getMedian(); }
void deactivatePump(void);
void activatePump(void);
/**
* @brief Check if a plant is too dry and needs some water.
*
@ -73,8 +66,17 @@ public:
HomieInternals::SendingPromise& setProperty(const String& property) const {
return mPlant->setProperty(property);
}
bool switchHandler(const HomieRange& range, const String& value);
void init(void);
bool isInCooldown(long sinceLastActivation) {
return (this->mSetting->pPumpCooldownInHours->get() > sinceLastActivation / 3600);
}
bool isAllowedOnlyAtLowLight(void) {
return this->mSetting->pPumpOnlyWhenLowLight->get();
}
};
#endif

View File

@ -20,6 +20,7 @@ Plant::Plant(int pinSensor, int pinPump,int plantId, HomieNode* plant, PlantSett
}
void Plant::init(void) {
/* Initialize Home Settings validator */
this->mSetting->pSensorDry->setDefaultValue(4095);
this->mSetting->pSensorDry->setValidator([] (long candidate) {
return (((candidate >= 0) && (candidate <= 4095) ) || candidate == DEACTIVATED_PLANT);
@ -38,8 +39,63 @@ void Plant::init(void) {
return ((candidate >= 0) && (candidate <= 1024) );
});
/* Initialize Hardware */
pinMode(this->mPinPump, OUTPUT);
pinMode(this->mPinSensor, ANALOG);
digitalWrite(this->mPinPump, LOW);
}
void Plant::addSenseValue(int analog) {
this->moistureRaw.add(analog);
void Plant::addSenseValue(void) {
this->moistureRaw.add( analogRead(this->mPinSensor) );
}
void Plant::postMQTTconnection(void) {
const String OFF = String("OFF");
this->mConnected=true;
this->mPlant->setProperty("switch").send(OFF);
}
void Plant::deactivatePump(void) {
digitalWrite(this->mPinPump, LOW);
if (this->mConnected) {
const String OFF = String("OFF");
this->mPlant->setProperty("switch").send(OFF);
}
}
void Plant::activatePump(void) {
digitalWrite(this->mPinPump, HIGH);
if (this->mConnected) {
const String OFF = String("ON");
this->mPlant->setProperty("switch").send(OFF);
}
}
void Plant::advertise(void) {
// Advertise topics
this->mPlant->advertise("switch").setName("Pump 1")
.setDatatype("boolean");
//FIXME add .settable(this->switchHandler)
this->mPlant->advertise("moist").setName("Percent")
.setDatatype("number")
.setUnit("%");
}
/* FIXME
bool Plant::switchHandler(const HomieRange& range, const String& value) {
if (range.isRange) return false; // only one switch is present
if ((value.equals("ON")) || (value.equals("On")) || (value.equals("on")) || (value.equals("true"))) {
this->activatePump();
return true;
} else if ((value.equals("OFF")) || (value.equals("Off")) || (value.equals("off")) || (value.equals("false")) ) {
this->deactivatePump();
return true;
} else {
return false;
}
}
}
*/

View File

@ -144,7 +144,7 @@ void mode2MQTT(){
digitalWrite(OUTPUT_PUMP, LOW);
for(int i=0; i < MAX_PLANTS; i++) {
digitalWrite(mPlants[i].mPinPump, LOW);
mPlants[i].deactivatePump();
}
if (deepSleepTime.get()) {
@ -200,7 +200,7 @@ void mode2MQTT(){
if(lastPumpRunning != -1 && hasWater){
digitalWrite(OUTPUT_PUMP, HIGH);
setLastActivationForPump(lastPumpRunning, getCurrentTime());
digitalWrite(mPlants[lastPumpRunning].mPinPump, HIGH);
mPlants[lastPumpRunning].activatePump();
}
if(lastPumpRunning == -1 || !hasWater){
if(getSolarVoltage() < SOLAR_CHARGE_MIN_VOLTAGE){
@ -311,7 +311,7 @@ void readSensors() {
/* wait before reading something */
for (int readCnt=0;readCnt < AMOUNT_SENOR_QUERYS; readCnt++) {
for(int i=0; i < MAX_PLANTS; i++) {
mPlants[i].addSenseValue(analogRead(mPlants[i].getSensorPin()));
mPlants[i].addSenseValue();
}
}
@ -354,7 +354,6 @@ void readSensors() {
//Homie.getMqttClient().disconnect();
void onHomieEvent(const HomieEvent& event) {
const String OFF = String("OFF");
switch(event.type) {
case HomieEventType::SENDING_STATISTICS:
mode2MQTT();
@ -370,15 +369,9 @@ void onHomieEvent(const HomieEvent& event) {
mode2MQTT();
Homie.getLogger() << "MQTT 1" << endl;
plant0.setProperty("switch").send(OFF);
plant1.setProperty("switch").send(OFF);
plant2.setProperty("switch").send(OFF);
plant3.setProperty("switch").send(OFF);
plant4.setProperty("switch").send(OFF);
plant5.setProperty("switch").send(OFF);
plant6.setProperty("switch").send(OFF);
for(int i=0; i < MAX_PLANTS; i++) {
mPlants[i].postMQTTconnection();
}
break;
case HomieEventType::READY_TO_SLEEP:
Homie.getLogger() << "rtsleep" << endl;
@ -405,13 +398,13 @@ int determineNextPump(){
long lastActivation = getLastActivationForPump(i);
long sinceLastActivation = getCurrentTime()-lastActivation;
//this pump is in cooldown skip it and disable low power mode trigger for it
if(mPlants[i].mSetting->pPumpCooldownInHours->get() > sinceLastActivation / 3600){
if(mPlants[i].isInCooldown(sinceLastActivation) ){
Serial.println("Skipping due to cooldown");
//setMoistureTrigger(i, DEACTIVATED_PLANT);
//continue;
}
//skip as it is not low light
if(!isLowLight && mPlants[i].mSetting->pPumpOnlyWhenLowLight->get()){
if(!isLowLight && mPlants[i].isAllowedOnlyAtLowLight()){
Serial.println("Skipping due to light");
continue;
}
@ -425,45 +418,6 @@ int determineNextPump(){
return -1;
}
bool switchGeneralPumpHandler(const int pump, const HomieRange& range, const String& value) {
if (range.isRange) return false; // only one switch is present
switch (pump)
{
#if MAX_PLANTS >= 1
case 0:
#endif
#if MAX_PLANTS >= 2
case 1:
#endif
#if MAX_PLANTS >= 3
#endif
case 2:
#if MAX_PLANTS >= 4
case 3:
#endif
#if MAX_PLANTS >= 5
case 4:
#endif
#if MAX_PLANTS >= 6
case 5:
#endif
if ((value.equals("ON")) || (value.equals("On")) || (value.equals("on")) || (value.equals("true"))) {
digitalWrite(mPlants[pump].getPumpPin(), HIGH);
return true;
} else if ((value.equals("OFF")) || (value.equals("Off")) || (value.equals("off")) || (value.equals("false")) ) {
digitalWrite(mPlants[pump].getPumpPin(), LOW);
return true;
} else {
return false;
}
break;
default:
return false;
}
}
/**
* @brief Handle Mqtt commands to keep controller alive
*
@ -484,43 +438,6 @@ bool aliveHandler(const HomieRange& range, const String& value) {
return true;
}
/**
* @brief Handle Mqtt commands for the pumpe, responsible for the first plant
*
* @param range multiple transmitted values (not used for this function)
* @param value single value
* @return true when the command was parsed and executed succuessfully
* @return false on errors when parsing the request
*/
bool switch1Handler(const HomieRange& range, const String& value) {
return switchGeneralPumpHandler(0, range, value);
}
/**
* @brief Handle Mqtt commands for the pumpe, responsible for the second plant
*
* @param range multiple transmitted values (not used for this function)
* @param value single value
* @return true when the command was parsed and executed succuessfully
* @return false on errors when parsing the request
*/
bool switch2Handler(const HomieRange& range, const String& value) {
return switchGeneralPumpHandler(1, range, value);
}
/**
* @brief Handle Mqtt commands for the pumpe, responsible for the third plant
*
* @param range multiple transmitted values (not used for this function)
* @param value single value
* @return true when the command was parsed and executed succuessfully
* @return false on errors when parsing the request
*/
bool switch3Handler(const HomieRange& range, const String& value) {
return switchGeneralPumpHandler(2, range, value);
}
void homieLoop(){
}
@ -548,38 +465,9 @@ void systemInit(){
mConfigured = Homie.isConfigured();
if (mConfigured) {
// Advertise topics
plant1.advertise("switch").setName("Pump 1")
.setDatatype("boolean")
.settable(switch1Handler);
plant1.advertise("moist").setName("Percent")
.setDatatype("number")
.setUnit("%");
plant2.advertise("switch").setName("Pump 2")
.setDatatype("boolean")
.settable(switch2Handler);
plant2.advertise("moist").setName("Percent")
.setDatatype("number")
.setUnit("%");
plant3.advertise("switch").setName("Pump 3")
.setDatatype("boolean")
.settable(switch3Handler);
plant3.advertise("moist").setName("Percent")
.setDatatype("number")
.setUnit("%");
plant4.advertise("moist").setName("Percent")
.setDatatype("number")
.setUnit("%");
plant5.advertise("moist").setName("Percent")
.setDatatype("number")
.setUnit("%");
plant6.advertise("moist").setName("Percent")
.setDatatype("number")
.setUnit("%");
plant0.advertise("moist").setName("Percent")
.setDatatype("number")
.setUnit("%");
for(int i=0; i < MAX_PLANTS; i++) {
mPlants[i].advertise();
}
sensorTemp.advertise("control")
.setName("Temperature")
.setDatatype("number")
@ -707,13 +595,10 @@ void setup() {
/* Intialize inputs and outputs */
pinMode(SENSOR_LIPO, ANALOG);
pinMode(SENSOR_SOLAR, ANALOG);
for(int i=0; i < MAX_PLANTS; i++) {
pinMode(mPlants[i].getPumpPin(), OUTPUT);
pinMode(mPlants[i].getSensorPin(), ANALOG);
digitalWrite(mPlants[i].getPumpPin(), LOW);
}
/* read button */
pinMode(BUTTON, INPUT);
/* Power pins */
pinMode(OUTPUT_PUMP, OUTPUT);
/* Disable Wifi and bluetooth */