fix cooldown memory without power, improved logging

This commit is contained in:
Your Name 2021-07-01 23:09:02 +02:00
parent 456f78042c
commit 12d4c9950d
2 changed files with 23 additions and 15 deletions

View File

@ -23,3 +23,4 @@
#define LOG_DEBUG_CODE 1001
#define LOG_NOPUMP_LOWLIGHT 100
#define LOG_NOPUMPS 101
#define LOG_MISSING_PUMP -4

View File

@ -65,10 +65,10 @@ void readPowerSwitchedSensors();
* NON VOLATILE VARIABLES in DEEP SLEEP
******************************************************************************/
RTC_SLOW_ATTR int lastPumpRunning = -1; /**< store last successfully waterd plant */
RTC_SLOW_ATTR long lastWaterValue = 0; /**< to calculate the used water per plant */
RTC_DATA_ATTR int lastPumpRunning = -1; /**< store last successfully waterd plant */
RTC_DATA_ATTR long lastWaterValue = 0; /**< to calculate the used water per plant */
RTC_SLOW_ATTR long rtcLastWateringPlant[MAX_PLANTS] = {0};
RTC_DATA_ATTR long rtcLastWateringPlant[MAX_PLANTS] = {0};
/******************************************************************************
* LOCAL VARIABLES
@ -105,7 +105,6 @@ Plant mPlants[MAX_PLANTS] = {
* LOCAL FUNCTIONS
******************************************************************************/
void espDeepSleepFor(long seconds, bool activatePump)
{
if (mDownloadMode)
@ -124,15 +123,18 @@ void espDeepSleepFor(long seconds, bool activatePump)
}
else
{
log(LOG_LEVEL_DEBUG, "NTP timeout before deepsleep", LOG_DEBUG_CODE);
break;
}
}
if (getCurrentTime() < 100000)
{
log(LOG_LEVEL_DEBUG, "NTP timeout before deepsleep", LOG_DEBUG_CODE);
}
}
esp_sleep_pd_config(ESP_PD_DOMAIN_RTC_PERIPH, ESP_PD_OPTION_OFF);
esp_sleep_pd_config(ESP_PD_DOMAIN_RTC_SLOW_MEM, ESP_PD_OPTION_ON);
esp_sleep_pd_config(ESP_PD_DOMAIN_RTC_FAST_MEM, ESP_PD_OPTION_OFF);
esp_sleep_pd_config(ESP_PD_DOMAIN_RTC_FAST_MEM, ESP_PD_OPTION_ON);
if (activatePump)
{
esp_sleep_pd_config(ESP_PD_DOMAIN_XTAL, ESP_PD_OPTION_ON);
@ -162,6 +164,7 @@ void espDeepSleepFor(long seconds, bool activatePump)
esp_sleep_enable_timer_wakeup((seconds * 1000U * 1000U));
if (mAliveWasRead)
{
delay(1000);
Homie.prepareToSleep();
}
else
@ -314,7 +317,7 @@ void readPowerSwitchedSensors()
}
else
{
log(LOG_LEVEL_WARN,LOG_TANKSENSOR_FAIL_DETECT,LOG_TANKSENSOR_FAIL_DETECT_CODE);
log(LOG_LEVEL_WARN, LOG_TANKSENSOR_FAIL_DETECT, LOG_TANKSENSOR_FAIL_DETECT_CODE);
}
/* deactivate the sensors */
@ -336,10 +339,13 @@ void onMessage(char *incoming, char *payload, AsyncMqttClientMessageProperties p
{
bool backupSucessful = copyFile(CONFIG_FILE, CONFIG_FILE_BACKUP);
printFile(CONFIG_FILE_BACKUP);
if(backupSucessful){
log(LOG_LEVEL_INFO,LOG_BACKUP_SUCCESSFUL, LOG_BACKUP_SUCCESSFUL_CODE);
}else {
log(LOG_LEVEL_INFO,LOG_BACKUP_FAILED, LOG_BACKUP_FAILED_CODE);
if (backupSucessful)
{
log(LOG_LEVEL_INFO, LOG_BACKUP_SUCCESSFUL, LOG_BACKUP_SUCCESSFUL_CODE);
}
else
{
log(LOG_LEVEL_INFO, LOG_BACKUP_FAILED, LOG_BACKUP_FAILED_CODE);
}
Homie.getMqttClient().publish(backupTopic, 2, true, "false");
}
@ -433,7 +439,7 @@ int determineNextPump()
if (plant.getCurrentMoisture() == MISSING_SENSOR)
{
plant.publishState("nosensor");
log(LOG_LEVEL_DEBUG, String(String(i) + " No pump possible: missing sensor"), LOG_DEBUG_CODE);
log(LOG_LEVEL_ERROR, String(String(i) + " No pump possible: missing sensor"), LOG_MISSING_PUMP);
continue;
}
if (plant.isPumpRequired())
@ -476,7 +482,8 @@ int determineNextPump()
*/
bool aliveHandler(const HomieRange &range, const String &value)
{
if (range.isRange) {
if (range.isRange)
{
return false; // only one controller is present
}