PlantCtrl/esp32/include/HomieConfiguration.h

69 lines
3.1 KiB
C
Raw Normal View History

/**
* @file HomieConfiguration.h
* @author your name (you@domain.com)
* @brief
* @version 0.1
* @date 2020-10-16
*
* @copyright Copyright (c) 2020
* All Settings, configurable in Homie
*/
#ifndef HOMIE_PLANT_CONFIG_H
#define HOMIE_PLANT_CONFIG_H
2020-10-16 16:22:48 +02:00
#include "HomieTypes.h"
#define MAX_PLANTS 7
/**
*********************************** Attributes *******************************
*/
HomieNode plant0("plant0", "Plant 0", "Plant");
HomieNode plant1("plant1", "Plant 1", "Plant");
HomieNode plant2("plant2", "Plant 2", "Plant");
HomieNode plant3("plant3", "Plant 3", "Plant");
HomieNode plant4("plant4", "Plant 4", "Plant");
HomieNode plant5("plant5", "Plant 5", "Plant");
HomieNode plant6("plant6", "Plant 6", "Plant");
HomieNode sensorLipo("lipo", "Battery Status", "Lipo");
HomieNode sensorSolar("solar", "Solar Status", "Solarpanel");
HomieNode sensorWater("water", "WaterSensor", "Water");
HomieNode sensorTemp("temperature", "Temperature", "temperature");
HomieNode stayAlive("stay", "alive", "alive");
/**
*********************************** Settings *******************************
*/
2020-10-31 12:44:32 +01:00
HomieSetting<long> deepSleepTime("deepsleep", "time in seconds to sleep (0 deactivats it)");
HomieSetting<long> deepSleepNightTime("nightsleep", "time in seconds to sleep (0 uses same setting: deepsleep at night, too)");
HomieSetting<long> wateringDeepSleep("pumpdeepsleep", "time seconds to sleep, while a pump is running");
HomieSetting<long> waterLevelMax("watermaxlevel", "distance (mm) at maximum water level");
HomieSetting<long> waterLevelMin("waterminlevel", "distance (mm) at minimum water level (pumps still covered)");
HomieSetting<long> waterLevelWarn("waterlevelwarn", "warn (mm) if below this water level %");
HomieSetting<long> waterLevelVol("waterVolume", "(ml) between minimum and maximum");
/** Plant specific ones */
2020-10-16 16:47:36 +02:00
#define GENERATE_PLANT(plant, strplant) \
HomieSetting<long> mSensorDry##plant = HomieSetting<long>("moistdry" strplant, "Plant " strplant "- Moist sensor dry threshold"); \
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("rangehourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("rangehourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
2020-10-16 16:47:36 +02:00
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("onlyWhenLowLightZ" strplant, "Plant" strplant " - Enable the Pump only, when there is light but not enought to charge battery"); \
HomieSetting<long> mPumpCooldownInHours##plant = HomieSetting<long>("cooldownpump" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
2020-10-20 22:52:03 +02:00
PlantSettings_t mSetting##plant = { &mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInHours##plant };
2020-10-16 16:47:36 +02:00
GENERATE_PLANT(0, "0");
GENERATE_PLANT(1, "1");
GENERATE_PLANT(2, "2");
GENERATE_PLANT(3, "3");
GENERATE_PLANT(4, "4");
GENERATE_PLANT(5, "5");
GENERATE_PLANT(6, "6");
2020-10-16 16:22:48 +02:00
#endif /* HOMIE_PLANT_CONFIG_H */