DD3 HIL test matrix

Area Stimulus Required evidence Expected result
Boot Flash/start both boards boot, role, periodic health from each Exactly one sender and receiver; no reset loop; bounded heap/stack
Time Sender receive window and receiver time-sync sender request/completion, receiver transmit Valid UTC completion; misses remain visible
Meter baseline Real optical meter meter_frame, meter_sample Frame classification and seconds index when present; no secrets/values logged
Batch Normal 30 s batching create, encode, every TX/RX chunk, complete, decode, ACK TX/RX One batch ID correlates end to end
Meter timeout Partial start then >1.5 s pause classification=timeout, health No reset; next valid fixture recovers
Meter malformed Each parser fixture then valid failure/partial classification, then valid No reset; failure is not treated as valid evidence
Meter time rollback/jump seconds fixtures meter_time rollback/jump Diagnostic classification; subsequent valid frame recovers
Oversize/slow >512-byte or slow fixture oversized or valid event, health Bounded buffers and continued operation
Drop chunk drop_chunk once incomplete transfer, retry, later complete/ACK Incomplete batch is not decoded; retry recovers
Duplicate chunk duplicate_chunk once duplicate/incomplete diagnostic, retry, later ACK No double publication; transfer recovers
Corrupt chunk post-CRC byte flip once lora_reject=crc_fail, retry, later ACK CRC rejects frame; incomplete batch not decoded
Suppress ACK suppress one ACK response receiver suppression, sender timeout/retry, later ACK Retry count increments and recovers
Delay ACK delay one ACK response delay event and ACK/retry timing No crash/deadlock; transfer recovers
Wrong ACK ID altered batch ID once sender rejected ack_rx, retry, correct ACK Incorrect ACK cannot complete inflight batch

For every fault case, compare health events before and after injection, require a later successful ACK, and inspect raw logs for resets. MQTT duplicate-publication evidence may require a separately approved broker observer; without it, report that assertion as blocked rather than inferring success solely from radio logs.