# DD3-LoRa-Bridge-MultiSender
|
|
|
|
Firmware for LilyGO T3 v1.6.1 (`ESP32 + SX1276 + SSD1306`) that runs in two roles:
|
|
- `Sender` (`GPIO14` HIGH): reads one IEC 62056-21 meter, builds 30-slot sparse batches, sends via LoRa.
|
|
- `Receiver` (`GPIO14` LOW): receives/ACKs batches, publishes MQTT, serves web UI, logs to SD.
|
|
|
|
## Architecture Summary
|
|
|
|
- Single codebase, role selected at boot by `detect_role()` (`src/config.cpp`).
|
|
- LoRa transport is wrapped with firmware-level CRC16-CCITT (`src/lora_transport.cpp`).
|
|
- Sender meter ingest is decoupled from LoRa waits via FreeRTOS meter reader task + queue on ESP32 (`src/main.cpp`).
|
|
- Batch payload codec is schema `v3` with a 30-bit `present_mask` over `[t_last-29, t_last]` (`src/payload_codec.cpp`).
|
|
- Sender only starts normal metering/transmit flow after valid time bootstrap from receiver ACK.
|
|
- Receiver runs STA mode if stored config is valid and connects, otherwise AP fallback.
|
|
|
|
## LoRa Protocol
|
|
|
|
On-air frame:
|
|
|
|
`[msg_kind:1][device_short_id:2][payload...][crc16:2]`
|
|
|
|
`msg_kind`:
|
|
- `0`: `BatchUp`
|
|
- `1`: `AckDown`
|
|
|
|
### BatchUp
|
|
|
|
Transport layer chunks payload into:
|
|
|
|
`[batch_id_le:2][chunk_index:1][chunk_count:1][total_len_le:2][chunk_payload...]`
|
|
|
|
Receiver reassembles all chunks before decode.
|
|
|
|
Payload codec (`schema=3`, magic `0xDDB3`) carries:
|
|
- metadata: sender ID, batch ID, `t_last`, `present_mask`, battery mV, error counters
|
|
- arrays per present sample: `energy_wh[]`, `p1_w[]`, `p2_w[]`, `p3_w[]`
|
|
|
|
`n == 0` with `present_mask == 0` is valid and used for sync request packets.
|
|
|
|
### AckDown (7 bytes payload)
|
|
|
|
`[flags:1][batch_id_be:2][epoch_utc_be:4]`
|
|
|
|
- `flags bit0`: `time_valid`
|
|
- ACK is repeated (`ACK_REPEAT_COUNT=3`, `ACK_REPEAT_DELAY_MS=200`)
|
|
- Sender sets local time only if `time_valid=1` and `epoch >= MIN_ACCEPTED_EPOCH_UTC` (`2026-02-01 00:00:00 UTC`)
|
|
|
|
## Time Bootstrap and Timezone
|
|
|
|
Sender boot starts in sync-only mode:
|
|
- `g_time_acquired=false`
|
|
- sends sync requests every `SYNC_REQUEST_INTERVAL_MS` (`15s`)
|
|
- does not run normal 1 Hz sample/batch flow yet
|
|
|
|
After valid ACK time:
|
|
- `time_set_utc()` is called
|
|
- `g_time_acquired=true`
|
|
- normal 1 Hz sampling + periodic batch transmission starts
|
|
|
|
Timezone:
|
|
- `TIMEZONE_TZ` from `include/config.h` is applied in `time_manager`.
|
|
- Web/OLED local-time rendering uses this timezone.
|
|
- Default: `CET-1CEST,M3.5.0/2,M10.5.0/3`.
|
|
|
|
## Sender Meter Path
|
|
|
|
Implemented by `src/meter_driver.cpp` and sender loop in `src/main.cpp`:
|
|
- UART: `Serial2`, `GPIO34`, `9600 7E1`
|
|
- ESP32 RX buffer enlarged to `8192`
|
|
- Frame detection `/ ... !`, timeout `METER_FRAME_TIMEOUT_MS=3000`
|
|
- Parsed OBIS fields:
|
|
- `0-0:96.8.0*255` meter Sekundenindex (hex u32)
|
|
- `1-0:1.8.0` total energy (auto scales Wh -> kWh when unit is Wh)
|
|
- `1-0:16.7.0` total active power
|
|
- `1-0:36.7.0`, `56.7.0`, `76.7.0` phase powers
|
|
|
|
Timestamp derivation:
|
|
- anchor offset: `epoch_offset = epoch_now - meter_seconds`
|
|
- sample epoch: `ts_utc = meter_seconds + epoch_offset`
|
|
- jump checks: rollback, wall-time delta mismatch, anchor drift
|
|
|
|
Sender builds sparse 30-slot windows and sends every `METER_SEND_INTERVAL_MS` (`30s`).
|
|
|
|
## Receiver Behavior
|
|
|
|
For decoded `BatchUp`:
|
|
1. Reassemble and decode.
|
|
2. Validate sender identity (`EXPECTED_SENDER_IDS` and payload sender ID mapping).
|
|
3. Reject unknown/mismatched senders before ACK and before SD/MQTT/web updates.
|
|
4. Send `AckDown` promptly for accepted senders.
|
|
5. Track duplicates per configured sender.
|
|
6. If duplicate: update duplicate counters/time, skip data write/publish.
|
|
7. If `n==0`: sync request path only.
|
|
8. Else reconstruct each sample timestamp from `t_last + present_mask`, then:
|
|
- append to SD CSV
|
|
- publish MQTT state
|
|
- update web status and last batch table
|
|
|
|
## MQTT
|
|
|
|
State topic:
|
|
- `smartmeter/<device_id>/state`
|
|
|
|
Fault topic (retained):
|
|
- `smartmeter/<device_id>/faults`
|
|
|
|
State JSON (`src/json_codec.cpp`) includes:
|
|
- `id`, `ts`, `e_kwh`
|
|
- `p_w`, `p1_w`, `p2_w`, `p3_w`
|
|
- `bat_v`, `bat_pct`
|
|
- optional link: `rssi`, `snr`
|
|
- `err_last`, `rx_reject`, `rx_reject_text`
|
|
- non-zero fault counters when available
|
|
|
|
Home Assistant discovery:
|
|
- enabled by `ENABLE_HA_DISCOVERY=true`
|
|
- publishes to `homeassistant/sensor/<device_id>/<key>/config`
|
|
- `unique_id` format is `<device_id>_<key>` (example: `dd3-F19C_energy`)
|
|
- device metadata:
|
|
- `identifiers: ["<device_id>"]`
|
|
- `name: "<device_id>"`
|
|
- `model: "DD3-LoRa-Bridge"`
|
|
- `manufacturer: "AcidBurns"`
|
|
|
|
## Web UI, Wi-Fi, SD
|
|
|
|
- Wi-Fi/MQTT/NTP/web-auth config is stored in Preferences.
|
|
- AP fallback SSID prefix: `DD3-Bridge-`.
|
|
- Default web credentials: `admin/admin`.
|
|
- AP auth requirement is controlled by `WEB_AUTH_REQUIRE_AP` (default `true`).
|
|
- STA auth requirement is controlled by `WEB_AUTH_REQUIRE_STA` (default `true`).
|
|
|
|
Web timestamp display:
|
|
- human-facing timestamps show `epoch (HH:MM:SS TZ)` in local configured timezone.
|
|
|
|
SD CSV logging (`src/sd_logger.cpp`):
|
|
- header: `ts_utc,ts_hms_local,p_w,p1_w,p2_w,p3_w,e_kwh,bat_v,bat_pct,rssi,snr,err_m,err_d,err_tx,err_last`
|
|
- `ts_hms_local` is local `HH:MM:SS` derived from `TIMEZONE_TZ`
|
|
|
|
History parser (`src/web_server.cpp`):
|
|
- accepts both:
|
|
- current layout (`ts_utc,ts_hms_local,p_w,...`)
|
|
- legacy layout (`ts_utc,p_w,...`)
|
|
- requires full numeric parse for `ts_utc` and `p_w` (rejects trailing junk)
|
|
|
|
OLED duplicate display:
|
|
- receiver sender-pages show duplicate rate as `pct (absolute)` and last duplicate as `HH:MM`.
|
|
|
|
## Build Environments
|
|
|
|
From `platformio.ini`:
|
|
- `lilygo-t3-v1-6-1`
|
|
- `lilygo-t3-v1-6-1-test`
|
|
- `lilygo-t3-v1-6-1-868`
|
|
- `lilygo-t3-v1-6-1-868-test`
|
|
- `lilygo-t3-v1-6-1-payload-test`
|
|
- `lilygo-t3-v1-6-1-868-payload-test`
|
|
- `lilygo-t3-v1-6-1-prod`
|
|
- `lilygo-t3-v1-6-1-868-prod`
|
|
|
|
Example:
|
|
|
|
```bash
|
|
python -m platformio run -e lilygo-t3-v1-6-1
|
|
```
|
|
|
|
## Test Mode
|
|
|
|
`ENABLE_TEST_MODE` replaces normal loops with `test_sender_loop` / `test_receiver_loop` (`src/test_mode.cpp`):
|
|
- Sender emits periodic JSON test payloads over LoRa.
|
|
- Receiver decodes test payloads, updates display test codes, publishes MQTT to:
|
|
- `smartmeter/<device_id>/test`
|