/** * @file HomieConfiguration.h * @author your name (you@domain.com) * @brief * @version 0.1 * @date 2020-10-16 * * @copyright Copyright (c) 2020 * All Settings, configurable in Homie */ #ifndef HOMIE_PLANT_CONFIG_H #define HOMIE_PLANT_CONFIG_H #include "HomieTypes.h" #define MAX_PLANTS 7 /** *********************************** Attributes ******************************* */ HomieNode plant0("plant0", "Plant 0", "Plant"); HomieNode plant1("plant1", "Plant 1", "Plant"); HomieNode plant2("plant2", "Plant 2", "Plant"); HomieNode plant3("plant3", "Plant 3", "Plant"); HomieNode plant4("plant4", "Plant 4", "Plant"); HomieNode plant5("plant5", "Plant 5", "Plant"); HomieNode plant6("plant6", "Plant 6", "Plant"); HomieNode sensorLipo("lipo", "Battery Status", "Lipo"); HomieNode sensorSolar("solar", "Solar Status", "Solarpanel"); HomieNode sensorWater("water", "WaterSensor", "Water"); HomieNode sensorTemp("temperature", "Temperature", "temperature"); HomieNode stayAlive("stay", "alive", "alive"); /** *********************************** Settings ******************************* */ HomieSetting deepSleepTime("deepsleep", "time in seconds to sleep (0 deactivats it)"); HomieSetting deepSleepNightTime("nightsleep", "time in seconds to sleep (0 uses same setting: deepsleep at night, too)"); HomieSetting wateringDeepSleep("pumpdeepsleep", "time seconds to sleep, while a pump is running"); HomieSetting waterLevelMax("watermaxlevel", "distance (mm) at maximum water level"); HomieSetting waterLevelMin("waterminlevel", "distance (mm) at minimum water level (pumps still covered)"); HomieSetting waterLevelWarn("waterlevelwarn", "warn (mm) if below this water level %"); HomieSetting waterLevelVol("waterVolume", "(ml) between minimum and maximum"); /** Plant specific ones */ #define GENERATE_PLANT(plant, strplant) \ HomieSetting mSensorDry##plant = HomieSetting("moistdry" strplant, "Plant " strplant "- Moist sensor dry threshold"); \ HomieSetting mPumpAllowedHourRangeStart##plant = HomieSetting("rangehourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \ HomieSetting mPumpAllowedHourRangeEnd##plant = HomieSetting("rangehourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \ HomieSetting mPumpOnlyWhenLowLight##plant = HomieSetting("onlyWhenLowLightZ" strplant, "Plant" strplant " - Enable the Pump only, when there is light but not enought to charge battery"); \ HomieSetting mPumpCooldownInHours##plant = HomieSetting("cooldownpump" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \ PlantSettings_t mSetting##plant = { &mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInHours##plant }; GENERATE_PLANT(0, "0"); GENERATE_PLANT(1, "1"); GENERATE_PLANT(2, "2"); GENERATE_PLANT(3, "3"); GENERATE_PLANT(4, "4"); GENERATE_PLANT(5, "5"); GENERATE_PLANT(6, "6"); #endif /* HOMIE_PLANT_CONFIG_H */