/** * @file HomieTypes.h * @author your name (you@domain.com) * @brief * @version 0.1 * @date 2020-10-16 * * @copyright Copyright (c) 2020 * All Settings, configurable in Homie */ #ifndef HOMIE_PLANT_CFG_CONFIG_H #define HOMIE_PLANT_CFG_CONFIG_H #include /** * @name Sensor types * possible sensors: * @{ **/ #define FOREACH_SENSOR(SENSOR) \ SENSOR(NONE) \ SENSOR(CAPACITIVE_FREQUENCY) \ SENSOR(ANALOG_RESISTANCE_PROBE) /** * @} */ #define GENERATE_ENUM(ENUM) ENUM, #define GENERATE_STRING(STRING) #STRING, enum SENSOR_MODE { FOREACH_SENSOR(GENERATE_ENUM) }; static const char *SENSOR_STRING[] = { FOREACH_SENSOR(GENERATE_STRING) }; //plant pump is deactivated, but sensor values are still recorded and published #define DEACTIVATED_PLANT -1 //special value to indicate a missing sensor when the plant is not deactivated but no valid sensor value was read #define MISSING_SENSOR -2 //plant uses only cooldown and duration, moisture is measured but ignored, allowedHours is ignored (eg. make a 30min on 30min off cycle) #define HYDROPONIC_MODE -3 //plant uses cooldown and duration and workhours, moisture is measured but ignored #define TIMER_ONLY -4 /** * @brief State of plants * */ #define PLANTSTATE_NUM_DEACTIVATED 0xF000 #define PLANTSTATE_NUM_NO_SENSOR 0xE000 #define PLANTSTATE_NUM_WET 0x0F00 #define PLANTSTATE_NUM_SUNNY_ALARM 0x0021 #define PLANTSTATE_NUM_ACTIVE_ALARM 0x0011 #define PLANTSTATE_NUM_ACTIVE_SUPESSED 0x001F #define PLANTSTATE_NUM_ACTIVE 0x0010 #define PLANTSTATE_NUM_SUNNY 0x0020 #define PLANTSTATE_NUM_COOLDOWN_ALARM 0x0031 #define PLANTSTATE_NUM_COOLDOWN 0x0030 #define PLANTSTATE_NUM_AFTERWORK_ALARM 0x0041 #define PLANTSTATE_NUM_AFTERWORK 0x0040 #define PLANTSTATE_STR_DEACTIVATED "deactivated" #define PLANTSTATE_STR_NO_SENSOR "nosensor" #define PLANTSTATE_STR_WET "wet" #define PLANTSTATE_STR_SUNNY_ALARM "sunny+alarm" #define PLANTSTATE_STR_ACTIVE_ALARM "active+alarm" #define PLANTSTATE_STR_ACTIVE_SUPESSED "active+supressed" #define PLANTSTATE_STR_ACTIVE "active" #define PLANTSTATE_STR_SUNNY "sunny" #define PLANTSTATE_STR_COOLDOWN_ALARM "cooldown+alarm" #define PLANTSTATE_STR_COOLDOWN "cooldown" #define PLANTSTATE_STR_AFTERWORK_ALARM "after-work+alarm" #define PLANTSTATE_STR_AFTERWORK "after-work" typedef struct PlantSettings_t { HomieSetting *pSensorDry; HomieSetting *pPumpAllowedHourRangeStart; HomieSetting *pPumpAllowedHourRangeEnd; HomieSetting *pPumpOnlyWhenLowLight; HomieSetting *pPumpCooldownInSeconds; HomieSetting *pPumpDuration; HomieSetting *pPumpPowerLevel; HomieSetting *pPumpMl; } PlantSettings_t; #endif