use chrono::{Datelike, Timelike, NaiveDateTime}; use chrono_tz::Europe::Berlin; use esp_idf_hal::delay::Delay; use esp_idf_svc::http::server::EspHttpServer; use plant_hal::{PlantCtrlBoardInteraction, PlantHal, CreatePlantHal, PLANT_COUNT}; use anyhow::{Context, Result}; use webserver::webserver::httpd; pub mod plant_hal; mod config; mod webserver { pub mod webserver; } fn main() -> Result<()>{ // It is necessary to call this function once. Otherwise some patches to the runtime // implemented by esp-idf-sys might not link properly. See https://github.com/esp-rs/esp-idf-template/issues/71 esp_idf_svc::sys::link_patches(); // Bind the log crate to the ESP Logging facilities esp_idf_svc::log::EspLogger::initialize_default(); log::info!("Startup Rust"); let git_hash = env!("VERGEN_GIT_DESCRIBE"); println!("Version useing git has {}", git_hash); let mut board = PlantHal::create()?; println!("Board hal init"); let time = board.time(); let mut cur = match time { Ok(cur) => cur, Err(err) => { log::error!("time error {}", err); NaiveDateTime::from_timestamp_millis(0).unwrap().and_utc() } }; //check if we know the time current > 2020 if cur.year() < 2020 { if board.is_day() { //assume TZ safe times ;) cur = *cur.with_hour(15).get_or_insert(cur); } else { cur = *cur.with_hour(3).get_or_insert(cur); } } println!("cur is {}", cur); //continous/interrupt? //check if boot button is pressed, if longer than 5s delete config and reboot into config mode let config = board.get_config(); match config { Ok(conf) => { }, Err(err) => todo!(), } let proceed = config.unwrap(); //check if we have a config file // if not found or parsing error -> error very fast blink general fault //if this happens after a firmeware upgrade (check image state), mark as invalid //blink general fault error_reading_config_after_upgrade, reboot after // open accesspoint with webserver for wlan mqtt setup //blink general fault error_no_config_after_upgrade //once config is set store it and reboot if proceed.tank_sensor_enabled() { } //is tank sensor enabled in config? //measure tank level (without wifi due to interference) //TODO this should be a result// detect invalid measurement value let tank_value = board.tank_sensor_mv(); match tank_value { Ok(tank_raw) => { println!("Tank sensor returned {}", tank_raw); }, Err(_) => { //if not possible value, blink general fault error_tank_sensor_fault board.general_fault(true); //set general fault persistent //set tank sensor state to fault }, } //measure each plant moisture let mut initial_measurements_a: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; let mut initial_measurements_b: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; let mut initial_measurements_p: [i32;PLANT_COUNT] = [0;PLANT_COUNT]; for plant in 0..PLANT_COUNT { initial_measurements_a[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::A)?; initial_measurements_b[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::B)?; initial_measurements_p[plant] = board.measure_moisture_hz(plant, plant_hal::Sensor::PUMP)?; } match board.wifi("C3MA", Some("chaosimquadrat"), 10000) { Ok(_) => println!("online mode"), Err(_) => { println!("Offline mode"); }, } //try connect wifi and do mqtt roundtrip // if no wifi, set general fault persistent //if no mqtt, set general fault persistent match board.sntp(1000*120) { Ok(new_time) => cur = new_time, Err(err) => { println!("sntp error: {}", err); } } println!("Running logic at utc {}", cur); let europe_time = cur.with_timezone(&Berlin); println!("Running logic at europe/berlin {}", europe_time); //if config battery mode //read battery level //if not possible set general fault persistent, but do continue //else //assume 12v and max capacity //if tank sensor is enabled //if tank sensor fault abort if config require is set //check if water is > minimum allowed || fault //if not, set all plants requiring water to persistent fault //for each plant //check if moisture is < target //state += dry //check if in cooldown //state += cooldown //check if consecutive pumps > limit //state += notworking //set plant fault persistent //pump one cycle // set last pump time to now //during pump state += active //after pump check if Pump moisture value is increased by config delta x // state -= active // state += cooldown // if not set plant error persistent fault // state += notworking //set consecutive pumps+=1 //check if during light time //lightstate += out of worktime //check battery level //lightstate += battery empty //check solar level if config requires //lightstate += stillday //if no preventing lightstate, enable light //lightstate = active //keep webserver in scope let webserver = httpd(true); let delay = Delay::new_default(); loop { //let freertos do shit delay.delay_ms(1001); } return Ok(()) } //error codes //error_reading_config_after_upgrade //error_no_config_after_upgrade //error_tank_sensor_fault