PlantCtrl/esp32/include/HomieConfiguration.h

103 lines
5.1 KiB
C
Raw Permalink Normal View History

2020-11-06 22:19:16 +01:00
/** \addtogroup Homie
* @{
*
* @file HomieConfiguration.h
* @author your name (you@domain.com)
* @brief
* @version 0.1
* @date 2020-10-16
*
* @copyright Copyright (c) 2020
* All Settings, configurable in Homie
2020-11-06 22:19:16 +01:00
*
*/
#ifndef HOMIE_PLANT_CONFIG_H
#define HOMIE_PLANT_CONFIG_H
2020-10-16 16:22:48 +02:00
#include "HomieTypes.h"
#define MAX_PLANTS 7
/**
2020-11-06 22:19:16 +01:00
* @name Attributes
* generated Information
* @{
**/
2020-12-21 17:07:15 +01:00
#define NUMBER_TYPE "number"
#define TEMPERATUR_SENSOR_LIPO "lipo"
#define TEMPERATUR_SENSOR_WATER "water"
#define TEMPERATUR_SENSOR_OUTSIDE "temp"
#define TEMPERATURE_NAME "Temperature"
#define TEMPERATURE_UNIT "°C"
2020-11-06 22:19:16 +01:00
HomieNode plant0("plant0", "Plant 0", "Plant"); /**< dynamic Homie information for first plant */
HomieNode plant1("plant1", "Plant 1", "Plant"); /**< dynamic Homie information for second plant */
HomieNode plant2("plant2", "Plant 2", "Plant"); /**< dynamic Homie information for first plant */
HomieNode plant3("plant3", "Plant 3", "Plant"); /**< dynamic Homie information for first plant */
HomieNode plant4("plant4", "Plant 4", "Plant"); /**< dynamic Homie information for first plant */
HomieNode plant5("plant5", "Plant 5", "Plant"); /**< dynamic Homie information for first plant */
HomieNode plant6("plant6", "Plant 6", "Plant"); /**< dynamic Homie information for first plant */
HomieNode sensorLipo("lipo", "Battery Status", "Lipo");
HomieNode sensorSolar("solar", "Solar Status", "Solarpanel");
HomieNode sensorWater("water", "WaterSensor", "Water");
HomieNode sensorTemp("temperature", "Temperature", "temperature");
2020-11-28 01:45:57 +01:00
HomieNode startupReason("startupReason", "startupReason", "startupReason");
2020-11-06 23:29:46 +01:00
HomieNode stayAlive("stay", "alive", "alive"); /**< Necessary for Mqtt Active Command */
2020-11-06 22:19:16 +01:00
/* @} */
/**
2020-11-06 22:19:16 +01:00
* @name Settings
* General settings for the controller
* @{
*/
HomieSetting<long> maxTimeBetweenMQTTUpdates("mqttSleep", "time in seconds to start into mode2");
2020-10-31 12:44:32 +01:00
HomieSetting<long> deepSleepTime("deepsleep", "time in seconds to sleep (0 deactivats it)");
HomieSetting<long> deepSleepNightTime("nightsleep", "time in seconds to sleep (0 uses same setting: deepsleep at night, too)");
HomieSetting<long> wateringDeepSleep("pumpdeepsleep", "time seconds to sleep, while a pump is running");
HomieSetting<long> waterLevelMax("watermaxlevel", "distance (mm) at maximum water level");
HomieSetting<long> waterLevelMin("waterminlevel", "distance (mm) at minimum water level (pumps still covered)");
HomieSetting<long> waterLevelWarn("waterlevelwarn", "warn (mm) if below this water level %");
HomieSetting<long> waterLevelVol("waterVolume", "(ml) between minimum and maximum");
HomieSetting<long> lipoSensorIndex("lipoTempIndex", "index onwire bus for lipo temperature sensor");
HomieSetting<long> waterSensorIndex("waterTempIndex", "index onwire bus for water temperature sensor");
HomieSetting<const char *> ntpServer("ntpServer", "NTP server (pool.ntp.org as default)");
2020-11-06 22:19:16 +01:00
/**
*@}
*/
/**
* @name Plant specific ones
* Setting for one plant
* @{
**/
#define GENERATE_PLANT(plant, strplant) \
HomieSetting<long> mSensorDry##plant = HomieSetting<long>("moistdry" strplant, "Plant " strplant "- Moist sensor dry threshold"); \
HomieSetting<long> mPumpAllowedHourRangeStart##plant = HomieSetting<long>("rangehourstart" strplant, "Plant" strplant " - Range pump allowed hour start (0-23)"); \
HomieSetting<long> mPumpAllowedHourRangeEnd##plant = HomieSetting<long>("rangehourend" strplant, "Plant" strplant " - Range pump allowed hour end (0-23)"); \
2020-10-16 16:47:36 +02:00
HomieSetting<bool> mPumpOnlyWhenLowLight##plant = HomieSetting<bool>("onlyWhenLowLightZ" strplant, "Plant" strplant " - Enable the Pump only, when there is light but not enought to charge battery"); \
HomieSetting<long> mPumpCooldownInHours##plant = HomieSetting<long>("cooldownpump" strplant, "Plant" strplant " - How long to wait until the pump is activated again (minutes)"); \
2020-11-06 23:29:46 +01:00
PlantSettings_t mSetting##plant = {&mSensorDry##plant, &mPumpAllowedHourRangeStart##plant, &mPumpAllowedHourRangeEnd##plant, &mPumpOnlyWhenLowLight##plant, &mPumpCooldownInHours##plant}; \
2020-12-21 16:26:53 +01:00
/**< Generate all settings for one plant \
* \
* Feature to start pumping only at morning: @link{SOLAR_CHARGE_MIN_VOLTAGE} and @link{SOLAR_CHARGE_MAX_VOLTAGE} \
2020-11-06 23:29:46 +01:00
*/
2020-11-06 22:19:16 +01:00
/**
* @}
*/
GENERATE_PLANT(0, "0"); /**< Homie settings for first plant */
GENERATE_PLANT(1, "1"); /**< Homie settings for second Plant */
GENERATE_PLANT(2, "2"); /**< Homie settings for third plant */
GENERATE_PLANT(3, "3"); /**< Homie settings for fourth plant */
GENERATE_PLANT(4, "4"); /**< Homie settings for fifth plant */
GENERATE_PLANT(5, "5"); /**< Homie settings for sixth plant */
GENERATE_PLANT(6, "6"); /**< Homie settings for seventh plant */
2020-10-16 16:22:48 +02:00
2020-11-06 22:19:16 +01:00
#endif /* HOMIE_PLANT_CONFIG_H @} */