# DD3-LoRa-Bridge-MultiSender Firmware for LilyGO T3 v1.6.1 (`ESP32 + SX1276 + SSD1306`) that runs in two roles: - `Sender` (`GPIO14` HIGH): reads one IEC 62056-21 meter, builds 30-slot sparse batches, sends via LoRa. - `Receiver` (`GPIO14` LOW): receives/ACKs batches, publishes MQTT, serves web UI, logs to SD. ## Architecture Summary - Single codebase, role selected at boot by `detect_role()` (`src/config.cpp`). - LoRa transport is wrapped with firmware-level CRC16-CCITT (`src/lora_transport.cpp`). - Sender meter ingest is decoupled from LoRa waits via FreeRTOS meter reader task + queue on ESP32 (`src/main.cpp`). - Batch payload codec is schema `v3` with a 30-bit `present_mask` over `[t_last-29, t_last]` (`src/payload_codec.cpp`). - Sender only starts normal metering/transmit flow after valid time bootstrap from receiver ACK. - Receiver runs STA mode if stored config is valid and connects, otherwise AP fallback. ## LoRa Protocol On-air frame: `[msg_kind:1][device_short_id:2][payload...][crc16:2]` `msg_kind`: - `0`: `BatchUp` - `1`: `AckDown` ### BatchUp Transport layer chunks payload into: `[batch_id_le:2][chunk_index:1][chunk_count:1][total_len_le:2][chunk_payload...]` Receiver reassembles all chunks before decode. Payload codec (`schema=3`, magic `0xDDB3`) carries: - metadata: sender ID, batch ID, `t_last`, `present_mask`, battery mV, error counters - arrays per present sample: `energy_wh[]`, `p1_w[]`, `p2_w[]`, `p3_w[]` `n == 0` with `present_mask == 0` is valid and used for sync request packets. ### AckDown (7 bytes payload) `[flags:1][batch_id_be:2][epoch_utc_be:4]` - `flags bit0`: `time_valid` - ACK is repeated (`ACK_REPEAT_COUNT=3`, `ACK_REPEAT_DELAY_MS=200`) - Sender sets local time only if `time_valid=1` and `epoch >= MIN_ACCEPTED_EPOCH_UTC` (`2026-02-01 00:00:00 UTC`) ## Time Bootstrap and Timezone Sender boot starts in sync-only mode: - `g_time_acquired=false` - sends sync requests every `SYNC_REQUEST_INTERVAL_MS` (`15s`) - does not run normal 1 Hz sample/batch flow yet After valid ACK time: - `time_set_utc()` is called - `g_time_acquired=true` - normal 1 Hz sampling + periodic batch transmission starts Timezone: - `TIMEZONE_TZ` from `include/config.h` is applied in `time_manager`. - Web/OLED local-time rendering uses this timezone. - Default: `CET-1CEST,M3.5.0/2,M10.5.0/3`. ## Sender Meter Path Implemented by `src/meter_driver.cpp` and sender loop in `src/main.cpp`: - UART: `Serial2`, `GPIO34`, `9600 7E1` - ESP32 RX buffer enlarged to `8192` - Frame detection `/ ... !`, timeout `METER_FRAME_TIMEOUT_MS=3000` - Parsed OBIS fields: - `0-0:96.8.0*255` meter Sekundenindex (hex u32) - `1-0:1.8.0` total energy (auto scales Wh -> kWh when unit is Wh) - `1-0:16.7.0` total active power - `1-0:36.7.0`, `56.7.0`, `76.7.0` phase powers Timestamp derivation: - anchor offset: `epoch_offset = epoch_now - meter_seconds` - sample epoch: `ts_utc = meter_seconds + epoch_offset` - jump checks: rollback, wall-time delta mismatch, anchor drift Sender builds sparse 30-slot windows and sends every `METER_SEND_INTERVAL_MS` (`30s`). ## Receiver Behavior For decoded `BatchUp`: 1. Reassemble and decode. 2. Send `AckDown` immediately. 3. Track duplicates per configured sender (`EXPECTED_SENDER_IDS`). 4. If duplicate: update duplicate counters/time, skip data write/publish. 5. If `n==0`: sync request path only. 6. Else reconstruct each sample timestamp from `t_last + present_mask`, then: - append to SD CSV - publish MQTT state - update web status and last batch table ## MQTT State topic: - `smartmeter//state` Fault topic (retained): - `smartmeter//faults` State JSON (`src/json_codec.cpp`) includes: - `id`, `ts`, `e_kwh` - `p_w`, `p1_w`, `p2_w`, `p3_w` - `bat_v`, `bat_pct` - optional link: `rssi`, `snr` - `err_last`, `rx_reject`, `rx_reject_text` - non-zero fault counters when available Home Assistant discovery: - enabled by `ENABLE_HA_DISCOVERY=true` - publishes to `homeassistant/sensor///config` ## Web UI, Wi-Fi, SD - Wi-Fi/MQTT/NTP/web-auth config is stored in Preferences. - AP fallback SSID prefix: `DD3-Bridge-`. - Default web credentials: `admin/admin`. - AP auth requirement is controlled by `WEB_AUTH_REQUIRE_AP` (default `false`). - STA auth requirement is controlled by `WEB_AUTH_REQUIRE_STA` (default `true`). Web timestamp display: - human-facing timestamps show `epoch (HH:MM:SS TZ)` in local configured timezone. SD CSV logging (`src/sd_logger.cpp`): - header: `ts_utc,ts_hms_utc,p_w,p1_w,p2_w,p3_w,e_kwh,bat_v,bat_pct,rssi,snr,err_m,err_d,err_tx,err_last` - `ts_hms_utc` is UTC `HH:MM:SS` History parser (`src/web_server.cpp`): - expects the current CSV layout above - legacy CSV layouts are not parsed (no backward compatibility) OLED duplicate display: - receiver sender-pages show duplicate rate as `pct (absolute)` and last duplicate as `HH:MM`. ## Build Environments From `platformio.ini`: - `lilygo-t3-v1-6-1` - `lilygo-t3-v1-6-1-test` - `lilygo-t3-v1-6-1-868` - `lilygo-t3-v1-6-1-868-test` - `lilygo-t3-v1-6-1-payload-test` - `lilygo-t3-v1-6-1-868-payload-test` - `lilygo-t3-v1-6-1-prod` - `lilygo-t3-v1-6-1-868-prod` Example: ```bash python -m platformio run -e lilygo-t3-v1-6-1 ``` ## Test Mode `ENABLE_TEST_MODE` replaces normal loops with `test_sender_loop` / `test_receiver_loop` (`src/test_mode.cpp`): - Sender emits periodic JSON test payloads over LoRa. - Receiver decodes test payloads, updates display test codes, publishes MQTT to: - `smartmeter//test`