Document multi-meter UART mapping and energy-only sender behavior
This commit is contained in:
37
README.md
37
README.md
@@ -1,7 +1,7 @@
|
||||
# DD3-LoRa-Bridge-MultiSender
|
||||
|
||||
Unified firmware for LilyGO T3 v1.6.1 (ESP32 + SX1276 + SSD1306) running as either:
|
||||
- `Sender`: reads meter values and sends binary batches over LoRa.
|
||||
- `Sender`: reads energy-only values from multiple IEC 62056-21 meters and sends binary batches over LoRa.
|
||||
- `Receiver`: accepts batches, ACKs with optional time, publishes to MQTT/web.
|
||||
|
||||
## Protocol (minimal)
|
||||
@@ -27,6 +27,9 @@ CRC16 validation is still required on every frame.
|
||||
### 1) `BATCH_UP`
|
||||
- Uses existing binary batch/chunk transport.
|
||||
- `sample_count == 0` is valid and means `SYNC_REQUEST`.
|
||||
- Payload starts with `schema_id`:
|
||||
- `0`: legacy schema (kept for compatibility)
|
||||
- `1`: `EnergyMulti` schema (ts + integer kWh for up to 3 meters)
|
||||
|
||||
### 2) `ACK_DOWN` (7 bytes)
|
||||
- `flags` (`u8`): bit0 = `time_valid`
|
||||
@@ -55,6 +58,37 @@ Only then:
|
||||
|
||||
This guarantees no pre-`2026-02-01` epoch reaches MQTT or SD/DB paths.
|
||||
|
||||
## Multi-meter sender mode
|
||||
|
||||
- Meter protocol: IEC 62056-21 ASCII Mode D
|
||||
- UART framing: `9600 7E1`
|
||||
- Extracted OBIS: only total energy `1-0:1.8.0`
|
||||
- Conversion: kWh is sent as integer using `floor` (`12345.67 -> 12345`)
|
||||
|
||||
### Meter count by build mode
|
||||
|
||||
- Debug builds (`SERIAL_DEBUG_MODE=1`): `METER_COUNT=2`
|
||||
- keeps USB serial logs on UART0
|
||||
- uses UART1 + UART2 for meters
|
||||
- Prod builds (`SERIAL_DEBUG_MODE=0`): `METER_COUNT=3`
|
||||
- no serial logging
|
||||
- reclaims UART0 for meter 3 RX
|
||||
|
||||
### Meter RX pins (TTGO T3 v1.6.1 defaults)
|
||||
|
||||
- `PIN_METER1_RX = GPIO34` (UART2 RX)
|
||||
- `PIN_METER2_RX = GPIO25` (UART1 RX)
|
||||
- `PIN_METER3_RX = GPIO3` (UART0 RX, prod only)
|
||||
|
||||
All pins are configurable in `include/config.h`.
|
||||
|
||||
## Receiver MQTT output (EnergyMulti)
|
||||
|
||||
For `schema_id=1`, MQTT payload includes integer fields:
|
||||
- `energy1_kwh`
|
||||
- `energy2_kwh`
|
||||
- `energy3_kwh` (when meter count is 3)
|
||||
|
||||
## Receiver behavior
|
||||
|
||||
On `BATCH_UP`:
|
||||
@@ -85,4 +119,5 @@ DS3231 RTC support was removed:
|
||||
```bash
|
||||
pio run -e lilygo-t3-v1-6-1
|
||||
pio run -e lilygo-t3-v1-6-1-test
|
||||
pio run -e lilygo-t3-v1-6-1-prod
|
||||
```
|
||||
|
||||
Reference in New Issue